Page 21

COM ports 1 and 2 of the IPL T S2 can be wired in a similar way as the IPL T S6, as shown in figure 2-10. Both can be wired using a 3.5 mm, 5-pole or 3-pole captive screw connector. N The IPL T S2 allows for use of either the 9-pin D connector on COM1 or

COM2. The 9-pin D connector COM ports and the captive screw connector COM ports cannot be connected simultaneously.

Identification

#, The unique user ID number (MAC address) of the unit (for j UID example, 00-05-A6-00-00-01).

Operation

Connect power cords and turn on the output display devices (projectors, monitors, VCRs), control devices (switchers, scalers, distribution amplifiers), interface, and input devices (PC, laptop, network equipment). Check indicator LEDs on the PC/laptop, on the interface, on the network hub/ router, and so on, to ensure that all the devices are plugged in and communicating. The IPL T S interface is now ready to be configured (see chapter 3, “Connection and Configuration”). If connection or communication problems occur, see “Troubleshooting” in chapter 4. If the troubleshooting tips do not help, check with your local network administrator, or call the Extron S3 Sales & Technical Support Hotline.

Front panel indicators The front panels of the IPL T S interfaces have several indicator LEDs that show the current status of communications to and from the unit. A reset button (b) is also available from the front panel, in a small recess next to the Power LED. COM R

TX

RTS

RX

CTS

IPL T S1

1

2

6

4

3

5

Figure 2-11, IPL T S1 front panel

IPL T S2 COM

ACT

1

2

3

4

5

CTS

8

2

RTS

9

LINK

RX

100

1

TX

R

7

6

Figure 2-12, IPL T S2 front panel

IPL T S Series • Installation and Operation

2-9

Page 22

Installation and Operation, cont’d

IPL T S4 COM

ACT

1

2

3

4

5

RX

TX

3

6

4

5

CTS

4

RTS

8

2

CTS

LINK

RTS

9

3

RX

100

1

TX

R

7

6

Figure 2-13, IPL T S4 front panel

IPL T S6 COM

4

6

ACT

1

2

3

4

5

6

4

TX

TX

3

3

RX

8

2

RX

LINK

CTS

5

RTS

9

3

RX

100

1

TX

R

COM

7

4

Figure 2-14, IPL T S6 front panel LED, A green LED lights to indicate that the interface is receiving a Power power. button (recessed), A multi-function reset button. See “Resetting the b Reset unit” later in this chapter for more information. LEDs, A green LED indicates data is being transmitted from the c TX corresponding serial port. LEDs, A green LED indicates data is being received by the d RX corresponding serial port. LEDs, A green LED indicates that the corresponding serial port is e RTS ready to send data. LEDs, A green LED indicates that the device controlled by the f CTS corresponding serial port is ready to accept data. (Activity) LED, A yellow LED indicates that data is being sent/ g ACT received. LED, A green LED indicates that the unit is connected to an active h LINK network. LED, A green LED indicates that the connection speed is 100 Mbps. If i 100 the LED is not lit, the connection speed is 10 Mbps.

Resetting the unit There are five reset modes available by pressing the Reset button (b) on the side panel. The Reset button is recessed, so use a pointed stylus, ballpoint pen, or Extron Tweeker to access it. See the following table for a summary of the modes.

2-10

C

Review the reset modes carefully. Using the wrong reset mode may result in unintended loss of flash memory programming, port reassignment, or a controller reboot.

C

The reset modes listed below (with the exception of Mode 2) close all open IP and Telnet connections and close all sockets.

IPL T S Series • Installation and Operation

Page 23

N If the Reset button is continuosly held down, every three seconds the LED pulses (blinks) and puts the unit in a different mode. The Mode 5 LED blinks three times, the third blink indicating that it is the last mode. The following modes are separate functions, not a continuation from Mode 1 to Mode 5. Reset Mode Comparison/Summary Mode Activation 1

Hold down the recessed Reset button while applying power to the IPL T S unit. After a mode 1 reset is performed, update the unit’s firmware to the latest version. Do not operate the unit’s firmware version that results from the mode 1 reset. If you want to use the factory default firmware, you must upload that version again.

2

Press and release the Reset button. Within 2 seconds type +++ on the keyboard.

Result

Purpose/Notes

The unit reverts to the factory default firmware. Event scripting will not start if the unit is powered on in this mode. All user files and settings (drivers, adjustments, IP settings, etc.) are maintained.

Use mode 1 to revert to the factory default firmware version if incompatibility issues arise with user-loaded firmware.

If you do not want to update firmware, or you performed a mode 1 reset by mistake, cycle power to the unit to return to the firmware version that was running prior to the mode 1 reset. Use the 0Q SIS command to confirm that the factory default firmware is no longer running (look for asterisks following the version number.)

The connected COM port becomes a console port to send SIS commands. Scripting remains on.

Mode 2 enables the SIS console port.

Mode 3 is useful for troubleshooting.

N If the three “+’s” (+++) are not enetered in the 2-second time frame, the COM port becomes a control port only.

3

Hold down the Reset button for about 3 sec. until the Reset LED blinks once, then press Reset momentarily (<1 sec.) within 1 second.

Mode 3 turns events on or off. During resetting, the Reset LED flashes 2 times if events are starting, 3 times if events are stopping.

4

Hold down the Reset button for about 6 sec. until the Reset LED has blinked twice (once at 3 sec., again at 6 sec.). Then press Reset momentarily (for <1 sec.) within 1 second.

Mode 4 • Enables ARP capability. • Sets the IP address back to factory default (192.168.254.254). • Sets the subnet back to factory default. • Sets the default gateway address back to the factory default. • Sets port mapping back to factory default. • Turns DHCP off. • Turns events off. The Reset LED flashes 4 times in quick succession during the reset.

5

Hold down the Reset button for about 9 sec. until the Reset LED has blinked three times (once at 3 sec., again at 6 sec., again at 9 sec.). Then press Reset momentarily (for <1 sec.) within 1 second.

Mode 5 performs a complete reset to factory defaults (except the firmware). • Does everything mode 4 does. • Resets almost all the real time adjustments: all audio settings, limit initial power up volume, power up/down delay, auto power down, and misc. options. This does not affect an optional MLS switcher, however. • Clears driver-port associations and port configurations (IR/RS-232). • Removes button configurations. • Resets all IP options. • Removes scheduling settings. • Removes/clears all files from switcher. The Reset LED flashes 4 times in quick succession during the reset.

Mode 4 enables you to set IP address information using ARP and the MAC address.

Mode 5 is useful if you want to start over with configuration and uploading, and also to replace events.

IPL T S Series • Installation and Operation

2-11

Page 24

Installation and Operation, cont’d

2-12

IPL T S Series • Installation and Operation

Page 25

IPL T S Series

3

Chapter Three

Connection and Configuration Connecting the Hardware Setting the Internet Protocol (IP) Address Configuration using Global Configurator Configuration using Embedded Web Pages Configuration using DataViewer

Page 26

Connection and Configuration Connecting the Hardware

To connect the IPL T S interface, connect the input and output devices to the unit. Use figure 3-1, below, as a guide. Extron IPL T S2

Ethernet Control Interface

Serial Cables to Controlled Devices (switcher, projector, etc.) M

CO

M

CO

# 09

UID

2

05

12

30

1

2

M2 CO M1 CO

N LA

TX TX

RX

RX

WER PO

V 12 MAX .5A

TCP/IP Network or

Ethernet

PC

Crossover Cable

Laptop

Figure 3-1, IPL T S interface connections

Ethernet connection Ethernet connection is used on an ongoing basis to connect the IPL T S unit to a LAN and to control the switching and display devices attached to the unit. To connect the unit to a LAN, do the following: 1.

Plug one end of a CAT 5, straight-through Ethernet cable into the rear panel Ethernet connector on the IPL T S unit. See figure 2-9 in chapter 2 for RJ-45 connector wiring information.

2.

Plug the other end of the Ethernet cable into a network switch or hub connected to an Ethernet LAN or to the Internet.

3.

From your PC, launch a Web browser and type in the IP address previously set up on the IPL T S (if this hasnt been set up, see “Setting the Internet Protocol (IP) Address” later in this chapter). This displays the System Status Web page.

Serial connection The IPL T S interface can be connected to any A/V device that has a serial control port. 1.

Connect one end of a serial cable to the rear panel COM port connector of the IPL T S unit. As an alternative, use a 3.5 mm, 5-pole captive screw connector where available.

N This captive screw connector must be wired appropriately. See figure 2-10 for pin assignments, if necessary.

3-2

IPL T S Series • Connection and Configuration

Page 27

Lighting Control RS-232

Extron MAV 62

Extron IPL T S4 M

3

CO

M

1

CO

2 05

M

M

CO

2

N

LA

RS-232

R

WE PO V

Matrix Switcher

Ethernet Control Interface

CO

12

30

09

D#

UI

2

X

12 MA .5A p pto

La D

DV R

LAY DISP ER POW

VC

206 MLC roller Cont

ME

TCP/IP Network

VOLU aLink

Medi

MAX/ MIN

RS-232

Ex tron

Extron MediaLink or Other Controller

Ethernet Remote User Control and Administrator Monitoring

Projector

Laptop

DVD

VCR

Figure 3-2, Typical IPL T S interface operating configuration Connect the other end of the serial cable to the display or switching device to be controlled through the IPL T S.

2.

Setting the Internet Protocol (IP) Address

The IPL T S Series units have a factory default IP address of 192.168.254.254. This IP address must be changed to an address that will operate on your local network. There are three ways to change the IP address setting: •

Add Device > Auto Config IP option in Global Configurator

•

IPL T S unit’s embedded Web pages

• Address Resolution Protocol (ARP) command Before you begin: 1.

Obtain a valid IP address for your IPL T S Series device from your A/V system’s network administrator.

2.

Write down the unit’s MAC address (a 12-digit number) found on a label on the rear panel of the unit (for example, 00-05-A6-01-0A-74).

3.

If the unit is not at it’s factory default IP address (192.168.254.254), perform a Mode 4 reset: a.

Hold down the Reset button until the Power LED blinks twice (6 seconds), then release.

b.

Press and release the Reset button again within 1 second. The Power LED blinks quickly four times, confirming the Mode 4 reset, which returns the unit to its factory default IP address.

IPL T S Series • Connection and Configuration

3-3

Page 28

Connection and Configuration, cont’d

IPL T S4

R

1

CTS

RTS

RX

CTS

TX

RTS

RX

TX

COM 100

1

3

LINK

2

4

ACT

2

Figure 3-3, IPL T S unit’s front panel LED, A green LED lights to indicate that the interface is a Power receiving power. Blinks four times to confirm a Mode 4 reset. button, The Reset button is recessed. Use an Extron b Reset Tweeker or similar tool to activate.

Setting the IP address using Global Configurator The preferred method for setting a unit’s IP address is to use the Extron Global Configurator (GC) application. If you have Global Configurator installed on a local PC, and have a GC project file open, proceed with the steps below. If you do not have Global Configurator installed, it is available as a free download from www.extron.com. The GC help file leads you through the process of creating a new GC project file, and provides an illustrated version of the procedure below. The IPL T S unit must be: • physically connected to the network

• at its factory default IP address To set an IP address with a GC project file open: 1.

From the Edit menu, select Add Device. The Add Device dialog box opens (see figure 3-4).

2.

Select the appropriate device type (for example, IPL T S4) in the IP Link® Device drop-down list.

3.

Enter the new IP address (for example, 10.14.195.40) in the Name/IP Address field.

4.

Enter a unique device name in the Display Name field.

5.

Click the Advanced >>> button. The Advanced options of the Add Device dialog are displayed, and the “Advanced >>>” button name changes to “Basic <<<”.

3-4

6.

Enable the Auto Configure IP Address check box.

7.

Enter the unit’s MAC address in the MAC Address field. The first six digits (00-05-0A) are pre-populated, and identify this unit as an Extron device. You only need to enter the final six digits. Dashes between digits are auto-filled.

8.

Click the Set button. The Auto Configure Successful dialog box opens.

9.

Click OK.

IPL T S Series • Connection and Configuration

Page 29

Figure 3-4, Setting the IP address in Global Configurator

Setting the IP address using embedded Web pages Each IPL T S unit contains an on-board Web server with interactive pages that can be used to configure the device. The IPL T S unit must be at its factory default IP address. To set an IP address via embedded Web pages: 1.

Connect an Ethernet crossover cable between the device and a local PC.

2.

On the PC, locate the TCP/IP Properties dialog box. On Windows® XP, the TCP/IP Properties dialog box is found at: Start > My Network Places > right-click to Properties > Local Area Connection > right-click to Properties > Internet Protocol (TCP/IP) > Properties.

3.

Record the current IP address, subnet mask, default gateway and DHCP settings. You will need this information later to return the PC to its original TCP/IP settings. IP Address: .

.

.

.

.

Subnet Mask:

4.

.

Enter the following:

IP address: 192.168.254.253

Subnet mask: 255.255.0.0

Default gateway: <blank>

IPL T S Series • Connection and Configuration

3-5

Page 30

Connection and Configuration, cont’d 5.

Click OK.

Figure 3-5, Internet Protocol (TCP/IP) Properties dialog box 6.

Open a Web browser on the local PC.

7.

Enter 192.168.254.254 in the browser’s Address field and press the Enter key. The IPL T S unit’s embedded Web page is displayed.

8.

Click the Configuration tab.

9.

Change the IP Address and Subnet Mask fields to the desired IP address and subnet mask.

10.

Click the Submit button. The new IP address and subnet mask are assigned to the device, and the Web browser connection is immediately lost. The device, with its new IP address and subnet mask is now ready to be connected to your A/V network.

3-6