Page 31

Figure 3-6, Web server System Settings screen To return the local PC to its original TCP/IP settings: 1.

Close the Web browser.

2.

Disconnect the Ethernet crossover cable from the PC and the device.

3.

Return to the TCP/IP Properties dialog box on the PC.

4.

Return the IP address, Subnet mask, Default gateway, and DHCP fields to their original settings.

5.

Reboot the PC.

Setting the IP address using the ARP command An IPL T S unit’s IP address can be set using the DOS Address Resolution Protocol (ARP) command. The IPL T S unit must be: • physically connected to the network

• at its factory default IP address To set an IP address using the ARP command: 1.

Open a command prompt window on a local PC. On Windows XP, a command prompt window can be found at: Start > All Programs > Accessories > Command Prompt

2.

At the command prompt type: arp - s<IP address><MAC address> example: C:\>arp -s 10.13.197.64 00-05-A6-00-30-5F The example command assigns IP address 10.13.197.64 to the device that has a MAC address of 00-05-A6-00-30-5F.

IPL T S Series • Connection and Configuration

3-7

Page 32

Connection and Configuration, cont’d

Figure 3-7, Executing the ARP command 3.

To confirm the new IP address is active, perform a ping command to the new IP address. example: C:\>ping 10.13.197.64

If the IP address setting was successful, the device replies 3 or more times: Reply from <IP address>: bytes=32 time <1ms TTL=64

Configuration using Global Configurator Global Configurator (GC) is a simple-to-use, yet comprehensive software application that allows non-programmers to configure a wide range of Extron IP Link-enabled products. GC provides an integrated environment for defining A/V control and monitoring system functionality from an easy-to-use graphical user interface. It’s simple enough to be used for configuring a single room controller, yet powerful enough to facilitate building a Web-based asset management and remote monitoring system for hundreds of A/V devices in multiple locations. Serial ports on the IPL T S Series devices can be configured using GC. Global Configurator is available for free from www.extron.com. To download Global Configurator:

3-8

1.

Open and Internet browser and advance to www.extron.com.

2.

Click the Download tab.

3.

Click the Global Configurator icon.

4.

Click the Download Now button.

5.

Complete the Personal Information form.

6.

Scroll down the page and review any related Technical Bulletins.

7.

Click the Download GCSW3XX.exe button.

8.

Follow the remaining system prompts.

IPL T S Series • Connection and Configuration

Page 33

Figure 3-8, Global Configurator Once installed on your local PC, Global Configurator can be used to configure your IPL T S Series device and the A/V devices that are attached to the S Series’ serial control ports. See the Global Configurator help file for instructions on how to: •

Download device drivers

•

Start Global Configurator

•

Create a GC project file

•

Add and configure IPL T S Series and A/V devices

Configuration using Embedded Web Pages

Each IPL T S unit contains an on-board Web server with interactive pages that can be used to configure the device. Web server pages are described in detail on the following pages.

IPL T S Series • Connection and Configuration

3-9

Page 34

Connection and Configuration, cont’d Connecting via the Web server pages To connect to an IPL T S Series device via its Web server pages: 1.

Open a Web browser on a local PC.

2.

Enter the device’s IP address in the browser’s Address field and press the Enter key. If the device is password-protected, you will be prompted for a password.

Figure 3-9, Web server Password dialog box 3.

Enter the appropriate administrator or user password.

4.

Click OK. The System Status page opens.

Figure 3-10, Web server System Status screen

3-10

IPL T S Series • Connection and Configuration

Page 35

System Status page The System Status page is a read-only page that provides the following status information: •

System Description, Model, Description, Part Number, Firmware, Date, and Time

•

IP Settings, Unit Name, DHCP setting, IP Address, Gateway IP Address, Subnet Mask, and MAC Address

•

Serial Port Settings, For each port: Port number, Port Type, Baud Rate, Data Bits, Parity, Stop Bits, and Flow Control

Figure 3-11, System Status screen

Configuration page The Configuration page has five sub-pages, which are described below.

System Settings The System Settings page grants access to view and change: •

IP Settings

•

Date/Time Settings

IPL T S Series • Connection and Configuration

3-11

Page 36

Connection and Configuration, cont’d

Figure 3-12, System Settings screen

Port Settings The Port Settings page grants access to view or change the Serial Port Settings: •

Serial port number, use a radio button to select the desired port

•

Port type, RS-232 (default), RS-422, 4S-485

•

Baud rate, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600 (default), 14400,

19200, 28800, 38400, 57600, 115200

•

Parity, 7, 8 (default)

•

Stop bits, 1 (default), 2

•

Flow control, None (default), Hardware, Software

•

Serial Bridging, On, Off (default)

•

Remote IP Address, view the remote IP address

•

Remote TCP Port, view the remote TCP port

Figure 3-13, Port Settings screen

3-12

IPL T S Series • Connection and Configuration

Page 37

Passwords The Passwords page fields include: •

Administrator Password, provides complete configuration control

•

User Password, allows view of configuration only

Figure 3-14, Passwords screen To clear a password, enter a single space, repeat the entry in the re-enter password field, then click the Submit button. If no administrator password is present, the user password is not saved.

Email Alerts Initial e-mail alerts must be created using Global Configurator software. The embedded Web pages only allow you to edit existing e-mail alert settings. The Email Alerts page allows you to: •

Edit your network’s mail server connection information

•

Edit e-mail addresses of those you wish to receive e-mail alerts

• Select the desired e-mail delivery files Fields include: •

Mail IP Address, the network’s mail server IP address

•

Domain Name, the network’s mail server domain name

•

SMTP Authentication Required, SMTP authentication is required to access the mail server

•

User Name, user name to access the network’s mail server

•

Password, password to access the network’s mail server

•

Email Address, e-mail addresses of those to receive e-mail alerts

•

File Name, file name of the desired e-mail message

IPL T S Series • Connection and Configuration

3-13

Page 38

Connection and Configuration, cont’d

Figure 3-15, Email Alerts screen

Firmware Upgrade The Firmware Upgrade page reports the current firmware level, and provides the capability to browse to and upload a new firmware file.

Figure 3-16, Firmware Upgrade screen

File Management page The File Management page allows you to create directories as well as upload, use, and delete custom Web pages. Use the Add Dir, Browse, Upload Files and Delete buttons to upload and manage your custom Web pages.

Figure 3-17, File Management screen

3-14

IPL T S Series • Connection and Configuration

Page 39

Configuration using DataViewer

DataViewer is an enhanced terminal emulation program that facilitates analysis of RS-232 and TCP/IP communication with Extron devices. The software allows users to send commands to a device and view the device’s responses in ASCII or hexadecimal format. Command and response logs can be saved in text or HTML format. The data display can be configured in several ways for improved analysis of data communication. Text colors and fonts are user-definable making it easy to differentiate between commands and responses. Four different screen view options are available for viewing commands and responses in the most effective configurations and formats. With the DataViewer Control Toolbar and Shift Toolbar, you can customize up to 20 shortcut keys. Shortcut keys can be used to automate repetitive communications tasks. DataViewer is ideal for troubleshooting device protocols and determining device timing. DataViewer is available free from www.extron.com. To download DataViewer: 1.

Open an Internet browser and advance to www.extron.com.

2.

Click the Download tab.

3.

Click the Control Software icon.

4.

Scroll to the description of DataViewer.

5.

Click the Download link in the far right column.

6.

Complete the Personal Information form.

7.

Click the Download DVSW1x2x0x4.exe button.

8.

Follow the remaining system prompts.

Figure 3-18, DataViewer main window To run DataViewer: 1.

Double-click the DataViewer icon that was placed on the PC desktop during the download procedure. The Communications Setup dialog box opens.

2.

Click the TCP/IP tab.

IPL T S Series • Connection and Configuration

3-15

Page 40

Connection and Configuration, cont’d 3.

Enter the device’s IP address in the Hostname/IP Address field.

4.

Click OK.

Figure 3-19, Communication Setup dialog box The DataViewer application opens (see figure 3-18). See the DataViewer help file for information on sending commands to the IPL T S Series device, and viewing the responses in the DataViewer user interface.

3-16

IPL T S Series • Connection and Configuration