Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 8

IPL T S Series IP Link Ethernet Control Interfaces User's Manual, pages 11 to 20

Pages 11 to 20 of 79

The original document is the PDF (4.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Extron IPL T S1, Extron IPL T S4 and Extron IPL T S2

Page 11

Each IPL T S Series interface comes with the Extron IP Link® technology including: •

A built-in Web server

•

A set of Web pages that can be used to configure the device

•

Flash memory to store the Extron GlobalViewer® application and A/V equipment device drivers

•

Compatibility with the free GlobalViewer application which provides a graphical user interface with which to remotely monitor and control your A/V network devices The IPL T S Series interface devices support the following network protocols: •

DHCP − Dynamic host configuration protocol

•

ICMP − Internet control message protocol

•

SMTP − Simple mail transfer protocol

•

Telnet − a computer/client communications protocol Document Camera RS-232

Codec

M CO

M CO

Extron IPL T S6

09

2

CO

05

12

30

D# UI

CO CO

N

CO

LA WER PO

Ethernet Control Interface with GlobalViewer ® Software

TX

2

M2

M5

M4

M3

TX

TX

V X 12 MA .5A

Projector

1

RX

TX

RX

RX

RX

RS-232

Lighting Control

TCP/IP Network

Ethernet

Remote User Control & Administrator Monitoring

Laptop

Projector

DVD

VCR

Figure 1-1, A typical IPL T S Series application

Features

IPL T S Series interface features include: Support for bidirectional RS-232, RS-422, and RS-485 serial communication, Allows remote and proactive monitoring and troubleshooting of serially-controlled devices. N The IPL T S1 supports RS-232 only. Serial port pass-through, Two-, four-, and six-port models can be configured for pass-through mode, enabling each pair of ports on the interfaces to pass through commands and control a single device.

IPL T S Series • Introduction

1-3

Page 12

Introduction, cont’d Web-based A/V asset management, When used with GlobalViewer software, the IPL T S interfaces provide a powerful, flexible way to manage, monitor, and control projectors, flat-panel displays, and other devices using a standard Ethernet network. Integral, high performance Web server, Each IPL T S interface features a built-in Web server with memory available for storing device drivers, GlobalViewer, and development of your own Web pages using “off-the-shelf” Web authoring software. Industry standard Ethernet protocols, All IPL T S models support industry standard Ethernet communication protocols, including ARP, DHCP, ICMP, UDP/IP, TCP/IP, Telnet, HTTP, and SMTP, accessed through an RJ-45 auto-sense 10/100 Mbps Ethernet LAN connection. Simultaneous multi-user support, Each IPL T S interface supports multiple concurrent users, improving system throughput. E-mail capabilities to enable support, With e-mail notification, technical support administrators can receive failure and service messages through an e-mail enabled cell phone, PDA, pager, or Internet e-mail account. Multiple levels of access with password protection, User access level authorizes limited entry to only pre-designated functions, while administrator access level permits full access to advanced settings. Configuration utility, Global Configurator software, a free, easy-to-use Windows®-based configuration utility, makes product setup simple and intuitive, no programming knowledge is required. Extensive library of device drivers, Device drivers allow Extron products to control various display and source devices, such as projectors, flat-panel displays, and DVD players. Extron has produced thousands of fully tested and uniformly modeled RS-232 and IR device drivers. Direct port access, Use existing software programs to control a device that has no Ethernet support. Any existing Extron product with a serial control port can be interfaced with a LAN. Built-in multi-level security, A user can control access to devices attached to the interface. Two levels of password protection provide appropriate security. Serial port connectivity, Provides serial ports on 9-pin D and/or 3.5 mm, captive screw connectors. Easy configuration and control, Easily control the interface in three ways: • The Internet Explorer® browser • A Web-based interface • DataViewer (or a standard Telnet client application) The IPL T S series requires no centralized processor to operate within a system. Multiple mounting options, Can be mounted under a desktop or podium, on a projector mount, or on a rack shelf.

1-4

IPL T S Series • Introduction

Page 13

IPL T S Series

2

Chapter Two

Installation and Operation Installation Overview Mounting the IPL T S Interface Rear Panel Features and Cabling Operation

Page 14

Installation and Operation Installation Overview

To install and set up an IPL T S interface, follow these steps: 1.

Turn all of the equipment off. Make sure that the video sources (DSS, cable boxes, or other devices), the IPL T S unit, the output devices (monitors, VCRs, projectors, and so on) and the serial controller are all turned off and disconnected from the power source.

2.

Mount the IPL T S interface. See “Mounting the IPL T S Interface”, below.

3.

Attach the cables. See “Connecting the Hardware” in chapter 3.

4.

Connect power cords and turn on the devices in the following order: output devices (projectors, monitors, speakers), IPL T S interface, serial controller or computer (PC), then input devices (DSS, cable boxes, and so on).

5.

Configure the IPL T S interface through DataViewer or Telnet, then access the unit using an Internet browser.

Mounting the IPL T S Interface UL guidelines for rack mounting The following Underwriters Laboratories (UL) guidelines pertain to the installation of an IPL T S Series unit onto a rack.

2-2

1.

Elevated operating ambient, If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer [Tma = +32 to +122 °F (0 to +50 °C)].

2.

Reduced air flow, Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

3.

Mechanical loading, Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

4.

Circuit overloading, Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.

Reliable earthing (grounding), Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (such as the use of power strips).

IPL T S Series • Installation and Operation

Page 15

Mounting options All units are easily mounted in a rack, under a desk or podium, or on a projector mount. Mounting kits and IPL T S Series device compatibility are shown in the table below. Kit PN

S1

MBU 125 Under-desk mount

Mounting Type

70-077-01

•

S2

S4

S6

MBU 123 Under-furniture mount

70-212-01

•

•

•

PMK 200 Projector mount

70-077-04

PMK 100 Projector mount

70-217-01

•

•

•

RSU 129 1U 9.5-inch Deep universal rack shelf

60-190-01

•

•

•

•

RSF 123 1U 3.5-inch Deep rack shelf

60-190-20

•

•

•

•

•

Rack mounting an IPL T S Series interface The following rack mount kits are available: •

PN 60-190-20

RSU 123 1U 3.5-inch Deep Rack Shelf Kit

• PN 60-190-01 RSU 129 1U Universal Rack Shelf Kit To rack mount an IPL T S Series unit: 1.

If present, remove the rubber feet from the bottom of the IPL T S unit.

2.

Secure the underside of the unit on the rack shelf with two 4-40 x 3/16-inch screws in opposite (diagonal) corners.

3.

Install additional unit(s) or blank panel(s) on the rack shelf as desired.

4.

Insert the shelf into the rack at the desired location.

5.

Secure the shelf to the rack using the supplied mounting screws.

T S2

TX

2

CO

M

RX

1

RTS

R

CTS

IPL

®

T S2

TX

1

CO

M

RX

R

1U Rack Shelf

2

RTS

IPL

CTS

100 LIN K AC T

®

100 LIN K AC T

1/4 Rack Width False Front Face Plate

T S2

TX

2

CO

M

RX

1

RTS

R

Use 2 mounting holes on opposite corners.

CTS

IPL

®

100 LIN K AC T

(2) 4-40 x 3/16" Screws

Figure 2-1, Rack mounting the interface on the rack shelf N Only products that are 3.5 inches deep can be mounted to a 1U 3.5-inch Deep Rack Shelf. Any 1U or 1-inch high rack-mountable Extron product can be mounted on the Universal 1U Rack Shelf (shown in the following diagram).

IPL T S Series • Installation and Operation

2-3

Page 16

Installation and Operation, cont’d

T S2

TX

2

CO M RX

1

RTS

R

CTS

IPL

®

T S2

TX

1

2

CO M RX

R

RTS

IPL

CTS

10 0 LINK AC T

®

10 0 LINK AC T

MD AS

DIST

RIBU

ER

N AM IES PL IFIER

TIO

Figure 2-2, Mounting the interface on the standard shelf

Furniture or projector mounting The following furniture and projector mount kits are available: •

PN 70-077-01

Furniture mount kit (for IPL T S1)

•

PN 70-077-04

Projector mount kit (for IPL T S1)

•

PN 70-212-01

Furniture mount kit (for IPL T S2, S4, S6)

• PN 70-217-04 Projector mount kit (for IPL T S2, S4, S6) To mount an IPL T S Series device to furniture: 1.

If present, remove the rubber feet from the bottom of the IPL T S unit.

2.

Attach the furniture mounting brackets to the unit with the supplied screws.

3.

Hold the unit with the attached brackets against the underside of the furniture. Mark the hole locations of the bracket on the mounting surface.

4.

Drill 3/32-inch (2 mm) diameter pilot holes, 1/4 inches (6.3 mm) deep in the underside of the mounting surface at the marked hole locations.

5.

Insert #8 wood screws into the four pilot holes. Tighten each screw until just less than 1/4 inches (6.3 mm) of the screw head protrudes above the surface.

6.

Hang the mounting bracket over the protruding screw heads. Slide the mounting brackets to the narrow end of the screw slots and tighten the mounting screws.

To mount an IPL T S Series device with a projector:

2-4

1.

If present, remove the rubber feet from the bottom of the IPL T S unit.

2.

Attach the projector mounting bracket to the unit with the supplied screws.

3.

Secure the unit to the projector post with the supplied mounting bolt.

IPL T S Series • Installation and Operation

Page 17

Projector Mounting Bracket

Mounting Bolt R

IPL T S2

2 1

TX

4

COM

2

RX RTS

CTS

100 LINK ACT

Furniture Mount

T S2

TX

CO RX

1

M RTS

R

2

CTS

IPL

Digital Projector

10 0 LINK AC T

Projector Mount

Figure 2-3, Mounting the interface

Rear Panel Features and Cabling

All connections, including power, control, input, and output, are on the back panel of the IPL T S interface. See figures 2-4, 2-5, 2-6, 2-7 for details on each model. 10 00-05-A6-00-00-01 12V 0.5 A

COM1

LAN

2

6

1

3

4

Figure 2-4, IPL T S1 interface back panel 10

6 COM1

00-05-A6-00-00-02

LAN

POWER

COM2

12V .5A MAX

1

2

3

COM1

COM2

TX RX

TX RX

4

5

7

Figure 2-5, IPL T S2 interface back panel N The IPL T S2 allows for use of either the 9-pin D connector or the captive screw connector on COM1 or COM2. The 9-pin D connector COM ports and the captive screw connector COM ports should not be connected simultaneously. 10

6

8

00-05-A6-00-00-04

COM1

COM3

COM2

COM4

7

9

LAN

POWER 12V .5A MAX

1

2

3

4

Figure 2-6, IPL T S4 interface back panel

IPL T S Series • Installation and Operation

2-5

Page 18

Installation and Operation, cont’d 6

10

COM1

00-05-A6-00-00-06 LAN

POWER

COM2

12V .5A MAX

1

2

3

COM3

COM4

COM5

COM6

TX RX

TX RX TX RX

TX RX

5

4

7

Figure 2-7, IPL T S6 interface back panel

Power connection, Plug the unit’s external 12 VDC power supply into this a Power connector. The power supply is provided with the unit. When you are connecting the power supply, voltage polarity is extremely important. Applying power with incorrect voltage polarity could damage the power supply and the interface. Identify the power cord negative lead by the ridges on the side of the cord.

C

Ridges

Smooth

A

A SECTION A–A

3/16" (5 mm) Max.

Power Supply Output Cord

Orange Captive Screw Connector

Ground +12 VDC Power Supply Output Cord External Power Supply (12 VDC, 1 A ) AC Power Cord

Figure 2-8, Power connector wiring N Do not tin the stripped power supply leads before installing the captive screw connector. Tinned wires are not as secure in the captive screw connectors and could pull out. C

The two power cord wires must be kept separate while the power supply is plugged in. Remove power before continuing.

To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter.

2-6

IPL T S Series • Installation and Operation

Page 19

Ethernet/LAN b LAN Activity LED, A blinking yellow LED indicates LAN activity. connector, An RJ-45 connector for a network connection. Use an c LAN Ethernet straight-through cable to connect to a switch, hub, or router, or an Ethernet crossover cable to connect directly to a PC.

Straight-through Cable

COM1

00-05-A6-00-00-02

(for connection to a switch, hub, or router) LAN

POWER

COM2

12V .5A MAX

2

3

COM1

COM2

TX RX

TX RX

4

End 1 Pin 1 2 3 4 5 6 7 8

Wire Color white-orange orange white-green blue white-blue green white-brown brown

End 2 Pin 1 2 3 4 5 6 7 8

Wire Color white-orange orange white-green blue white-blue green white-brown brown

Pins: 12345678

Crossover Cable

(for direct connection to a PC)

End 1

Side View

Insert Twisted Pair Wires

RJ-45 Connector

Pin 1 2 3 4 5 6 7 8

Wire Color white-orange orange white-green blue white-blue green white-brown brown

End 2 Pin 1 2 3 4 5 6 7 8

Wire Color white-green green white-orange blue white-blue orange white-brown brown

Figure 2-9, RJ-45 connector wiring d Link LED, A lit green LED indicates a good LAN connection. Serial Communication screw connector, Plug a 3.5 mm, 5-pole captive screw connector e Captive into this socket for serial ports 1 and 2 (IPL T S2) or serial ports 3 through 6 (IPL T S6) connections. Pacing and handshaking are not supported via the captive screw connectors.

N The two IPL T S2 captive screw connectors are in parallel with the two 9-pin D connectors. For each serial port on the S2 use either the captive screw connector or the 9-pin D connector, but not both.

f COM1, 9-pin D connector for serial port 1 g COM2, 9-pin D connector for serial port 2 h COM3, 9-pin D connector for serial port 3 (S4 only) i COM4, 9-pin D connector for serial port 4 (S4 only)

IPL T S Series interface devices can be used to control display devices, switchers, and other A/V equipment via an RS-232/RS-422/RS-485 connection.

IPL T S Series • Installation and Operation

2-7

Page 20

Installation and Operation, cont’d Factory default protocol for the control interface is: •

RS-232

•

9600 baud

• no parity

•

8 data bits

•

1 stop bit

• pacing = 0 ms

• handshaking = off Communication to an attached device can be done through the IPL T S Series device’s default Web pages or by using the Extron Simple Instruction Set (SIS™) commands. The rear panel 9-pin D connector COM ports have the following pin assignments: Pin

Function

RS-232

RS-422

RS-485

2

Receive Data/Receive Data -

RX

RX-

3

Transmit Data/ Transmit Data -

TX

TX-

Data (pins 2 + 3 tied)

5

Signal Ground

GND

GND

GND

7

Request to Sent/Transmit Data +

RTS

TX+

8

Clear to Send/Receive Data +

CTS

RX+

Data + (pins 7 + 8 tied)

N The IPL T S1 uses RS-232 only. When using RS-485 with the connections indicated above, Data + can connect to either pin 7 or pin 8, and Data - can connect to either pin 2 or pin 3. For RS-232 communication, pins 7 and 8 (RTS and CTS) are optional. 5

1

9 6 9-Pin D Connector Pin Locations, Female

IPL T S2

IPL T S6

Connectors

Connectors

COM1

COM2

COM3

COM4

COM5

COM6

TX RX

TX RX

TX RX

TX RX TX RX

TX RX

Heat Shrink

7/8” (22 mm) 1/8” (3 mm)

3/16” (5 mm) Max.

Transmit Receive Ground Transmit Receive

Transmit Receive Ground Transmit Receive

Transmit Receive Ground Transmit Receive

5-pole Captive Screw Connector

Figure 2-10, 5-pin captive screw assignments

2-8

IPL T S Series • Installation