Page 63

System Configuration 2. Click Basic PPP Settings. • If you are using PPP, select Enable Dynamic IP Address Pool for Incoming Connections. • Enter the first reserved IP address of the incoming connections and the number of addresses to use and • Click Apply.

Chapter 3

Configure Network and Serial Ports

63

Page 64

System Configuration 3. Click Incoming PPP Connections > New Connection. Enter the appropriate parameters and click Apply.

4. Click Reboot for changes to take effect.

64

Chapter 3 Configure Network and Serial Ports

Page 65

System Configuration Configure Outgoing PPP Connections

For outgoing connections, CHAP or PAP authentication, or password configuration, use the following procedure. 1. On the main Point-to-Point Protocol (PPP) page, click Outgoing Connections. 2. Click New Connection. The Outgoing PPP Connection settings page is displayed. Enter the appropriate parameters. Note that CHAP authentication can be used to restrict PPP user access to outbound ports. When done, click Apply.

3. Click Reboot for changes to take effect. For dynamic routing or proxy ARP settings, follow the procedure for configuring advanced PPP settings, next.

Chapter 3

Configure Network and Serial Ports

65

Page 66

System Configuration Configure Advanced PPP Settings

1. On the main Point-to-Point Protocol (PPP) page, click Advanced PPP settings. • As needed, use the Help button above the settings for more information about configuring advanced PPP settings. • Select Enable Dynamic Routing (RIPv1). • Select the passive or active route setting. • Select the Process ARP requests if appropriate. • Click Apply.

2. Click Reboot for changes to take effect.

66

Chapter 3 Configure Network and Serial Ports

Page 67

System Configuration Configure SNMP Settings 1. On the main menu, click System > SNMP. 2. On the SNMP settings page: • Select Enable SNMP. • Enter the community (public or private). • Select the type or types of traps you wish to enable. • Click Apply.

Chapter 3

Configure Network and Serial Ports

67

Page 68

System Configuration Configure MEI Settings MEI settings apply to EIA-422/485 Half-Duplex (2 wire) ports only. See "Configure MEI Settings" on page 89 for details on MEI. 1. Select System > MEI. 2. Select the baud rate from the Maximum drop down box. 3. Click Apply for configuration to take effect.

68

Chapter 3 Configure Network and Serial Ports

Page 69

Autoconnection

Autoconnection The autoconnection feature allows you to configure a user to access the device server and then be automatically connected to a host on the LAN. You can implement autoconnection in the following ways: • By port, where all port users are automatically connected to the same host. The device server is completely transparent to them. • By user, where a user is required to log on and may be required to supply a password. Once the user is authenticated, an automatic connection to a host is made. Configure a Port for Autoconnection 1. Under Configuration, select Serial Ports. 2. Click the TCP Sockets Port Profile. Note that TCP Sockets is the port profile to use for Autoconnection. 3. Click Apply. 4. Select Automatically establish TCP connections and the appropriate parameters. Use the Help button for additional information. 5. Click Apply. 6. Click Reboot for changes to take effect. Note:

To return to the main Ports menu, choose Ports from the Menu again.

Configure a User for Autoconnection 1. Click Users from the menu. 2. Choose New User. 3. Enter a username and click Next. 4. Select the Terminal/Terminal Emulation user profile and click Next. 5. Select Automatically connect to a ... Be sure to specify the following: • Hostname or IP address that will be the destination • Service (Telnet, Rlogin, raw TCP, or SSL) • Destination TCP port number, which determines the type of connection for this user (such as 23 for Telnet) 6. Click Next and choose to verify the settings. 7. Click Finish to save settings.

Chapter 3

Configure Network and Serial Ports

69

Page 70

Autoconnection

70

Chapter 3 Configure Network and Serial Ports