Page 54
Port Profiles Power Management Port Profile The Power Management port profile allows you to connect the serial port to a power controller, such as the Digi Remote Power Manager (Digi RPM). The Digi device will monitor the power controller to provide the status and control of power outlets. This feature is used most commonly in a console management application, where the console port of a server is connected to one serial port of the Digi device for remote access, and the AC power plug of the server is connected to a power controller for AC power control. Power controller settings can be automatically detected or configured manually. Power controller outlets are configured on the Controller Outlets page, linked from the profile page. For more information on integrating the Digi RPM power controller with your Digi device, see Chapter 8, "Digi Remote Power Manager (Digi RPM)".
54
Chapter 3 Configure Network and Serial Ports
Page 55
Port Profiles Custom Port Profile The Custom port profile allows you to see all settings and set them accordingly. Use this profile only if your application does not fit into any of the predefined port profiles.
Chapter 3
Configure Network and Serial Ports
55
Page 56
User Configuration
User Configuration Although it is not required, the device server is often configured to accommodate the requirements of particular users. Typical configurable user attributes include: • Whether the user is required to supply a password. • Autoconnection attributes, such as the system to which the user should be automatically connected at login. • The interface the device presents the user, such as a menu or command line. • Whether the user has access to outbound ports. Users select a user profile that most closely describes the user’s environment. User profiles include: • Console Management - expected to connect to and manage serial devices that have a console port. Users can connect directly, use a custom menu interface, or reverse telnet or SSH into a serial port. • Terminal/Terminal Emulation -using a terminal or terminal emulation program to connect to the serial port and needs to automatically connect to a device available on the network. • Custom - using a terminal or terminal emulation program to connect to the serial port and needs to automatically connect to a device available on the network. • With a RADIUS server. See the “set radius” command description in the Digi One and PortServer TS Family Command Reference. Common User Features Feature
56
Description accesstime
Determines the times and days the user can access the device server. This feature is not configurable from the web interface.
autoconnect
Automatically connects the user to the host specified on the autohost field using the service (TCP port) defined on the autoport or autoservice fields. Autoconnection can also be implemented by port instead of by user.
Default access type
Defines the type of access the user is restricted to. Menu, command line, autoconnect, and outgoing and netservice are the types.
Menu access
Defines the menu that is to be presented to a user with menu access.
Port access
Defines the number of outbound ports a user connected over the LAN can access at one time. This feature is not configurable from the web interface.
PPP
Defines PPP-related parameters for the user. For more information on configuring PPP users, see "PPP Settings" on page 62.
Routing updates
Defines whether RIP routing updates are forwarded over the link to this user.
Chapter 3 Configure Network and Serial Ports
Page 57
User Configuration Add a User 1. Click Users > New User. 2. The new user wizard is displayed. Enter the Username, password, and password confirmation, and click Enter.
3. Select a profile that fits the user’s environment and needs, and click Next.
Chapter 3
Configure Network and Serial Ports
57
Page 58
User Configuration 4. Select the Ports to manage or the Autoconnect function if needed and click Next. 5. Review settings and click Finish. The Advanced tab under User allows you to set Escape characters for Connect, Telnet, Rlogin, and Kill as well as an SSH Public Key. 6. Click Apply to save the settings. 7. Click Reboot for changes to take effect. 8. User attributes can be changed after the user is set up. Select Users > username. From here you can change the password, the access method, the menu, or verify the user’s properties. Configure User Access Method 1. Set up the user as described in the previous procedure. 2. Click Users > username to assign access and select the access method or methods. 3. Select the ports for the user and click Apply. Change or Update User Passwords On the Users page, you can also change or update the users password. However, if the Admin password is lost, the only recovery is factory default reset. See "Reset Device Configuration to Factory Defaults" on page 122.
58
Chapter 3 Configure Network and Serial Ports
Page 59
Security Configuration
Security Configuration Security settings allow the administrator to set passwords, security levels, and authentication via RADIUS server. Enable/Disable Access to Network Services Some network services, such as Telnet and Rlogin, can be disabled for inbound users. This means that the users cannot access the Digi device using those services. This feature allows you to turn off individual services or to specify a security level, which means that all services not included in that level are turned off. The following services can be turned off. • SSH • Reverse SSH • HTTPS • HTTP • SNMP • • • • • • • • •
Chapter 3
RealPort Secure RealPort Secure Sockets Telnet Remote Login (RLogin) Remote Shell (RSH) Reverse TCP Reverse Telnet Line Printer Daemon (LPD)
Configure Network and Serial Ports
59
Page 60
Security Configuration Configure Security Settings 1. Click Security > and enter a new password for the root administrator username. 2. Enter the confirmation password and click Apply. 3. Click Network Security. Select the security level appropriate to your environment, and click Apply. Secure Access Levels are defined as follows: • Secure: SSH is the only service available to inbound users. • High: SSH, HTTP, SNMP, and RealPort services are available to inbound users. • Normal: all services are available. • Custom, which means you can select services to turn off. The default service level is Normal. 4. Click RADIUS and select Authenticate users via RADIUS server. If you do not have RADIUS available, Click Apply and then Reboot. 5. Enter the Primary server’s IP address and Primary server’s secret, which is the password used for encryption of messages between the RADIUS server and the Digi device. Click Apply. 6. Click Reboot for changes to take effect.
60
Chapter 3 Configure Network and Serial Ports
Page 61
System Configuration
System Configuration System settings allow you to set a system description, tune the performance optimizing throughput or latency, set the the date and time, configure SNMP traps, conifgure the idle timeout to close connected web interface clients after a specified idle time, and set baud rates for MEI. 1. Click System and enter the following: •
System Description: the SNMP Device Name assigned to the Digi device. • Contact: the SNMP contact person -often the network administrator. • Location: a text description of the physical location of the Digi device. • Optimization: the bandwidth used on the network. Options here are: Latency: Allows fast access to time-sensitive devices. Requires more network bandwidth. Throughput: Allows better network performance at higher throughput. Click Apply. 2. Click Date/Time. If your Digi device does not have Date/Time available, Click Reboot. 3. Enter the date and time information and click Apply. 4. Click Reboot for changes to take effect.
Chapter 3
Configure Network and Serial Ports
61
Page 62
System Configuration PPP Settings Under Applications > PPP , you can set the PPP (Point-to-Point Protocol) options to enable or disable the dynamic IP address pool. The dynamic IP address pool is a set of reserved IP addresses unique to the network that are assigned to the incoming connections. In the setup process, you set the IP address to use and the number of sequential addresses (plus one) to be reserved for assignment. A wizard and online help are availble to help you configure PPP settings. Configure Incoming PPP Connections
1. On the main menu, go to Applications > PPP. The main Point-to-Point Protocol (PPP) page is displayed.
62