Bar Code Handy Terminal BHT-6000 User's Manual: Chapter 2 Getting Started the BHT-6000 and System Mode, pages 62 to 71

Pages 62 to 71 of 178, from Bar Code Handy Terminal BHT-6000 User's Manual

The original document is the PDF (973 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the NipponDenso CU-6002 and Denso CU-6002

Page 62

Chapter 2. Getting Started the BHT-6000 and System Mode

[4.5]

Setting the resume function

SET RESUME 1:ON

2:OFF

Selecting "5: RESUME" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 ON

: Activates the resume function which resumes whatever display was shown before the power was turned off, when the BHT-6000 is powered up.

2 OFF

: Deactivates the resume function.

Select a desired item by using the numerical keys or F5 and F6 keys. To return to the SET SYSTEM menu, press the C key.

47

Page 63

[4.6]

Setting the communications environments

After the BHT-6000 is initialized, the interface port and communications parameters are set as listed in the default table below. Do not access them unless necessary. Interface port

OPT (Optical interface port)

Communications protocol

BHT-protocol Defaults

Communications parameters for the optical interface port TRANSMIT SPEED

9600 bps

PULSE WIDTH (Output pulse width of IR beam)

1.63 µs

PROTOCOL (Protocol options)

SERIAL No. ON: Adds serial numbers to data blocks. H. PARITY ON:

Adds a horizontal parity.

LINKUP TIME:

30 seconds

FIELD SPACE:

Ignore

Listed below are the default communications parameters for the direct-connect interface Defaults

Communications parameters for the direct-connect interface port TRANSMIT SPEED

19200 bps

PARITY BIT

None

DATA BIT (Character length)

8 bits

STOP BIT

1 bit

PROTOCOL (Protocol options)

SERIAL No. ON: Adds serial numbers to data blocks. H. PARITY ON:

Adds a horizontal parity.

LINKUP TIME:

30 seconds

FIELD SPACE:

Ignore

48

Page 64

Chapter 2. Getting Started the BHT-6000 and System Mode

SET COM 1:OPTICAL 2:CONNECTOR 3:COM PORT 4:PROTOCOL TYPE

Selecting the "6: COM" on the SET SYSTEM menu calls up the screen shown at left. 1 OPTICAL:

Switches to the communications parameters setting screen for the optical interface.

2 CONNECTOR:

Switches to the communications parameters setting screen for the direct-connect interface.

3 COM PORT:

Switches to the interface port setting screen.

4 PROTOCOL TYPE:

Switches to the communications protocol type setting screen.

Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.

[4.6-1]

Setting the communications parameters for the optical interface

SET OPTICAL 1:TRANSMIT SPEED 2:PULSE WIDTH 3:PROTOCOL

Selecting "1:OPTICAL" on the SET COM menu calls up the screen shown at left. 1 TRANSMIT SPEED:

Switches to the transmission speed screen.

2 PULSE WIDTH:

Switches to the IR beam output pulse width screen.

3 PROTOCOL:

Switches to the communications protocol option menu.

Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET COM menu, press the C key.

49

Page 65

(1)

Transmission speed screen

SET SPEED < OPTICAL > 1: 2400 4: 38400 2: 9600 5: 57600 3:19200 6:115200

Selecting "1:TRANSMIT SPEED" on the SET OPTICAL screen calls up the screen shown at left. Select the desired transmission speed by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET OPTICAL screen, press the C key.

(2)

IR beam output pulse width screen

SET PULSE WIDTH < OPTICAL >

Selecting the "2:PULSE WIDTH" on the SET OPTICAL screen calls up the screen shown at left.

1:1.63us 2:3/16 Bit Time

1 1.63us:

1.63 µs

2 3/16 Bit Time:

3/16 bit time

Select the desired pulse width by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET OPTICAL screen, press the C key.

(3)

Communications protocol option menu

SET PROTOCOL < OPTICAL > 1:SERIAL No. 2:H.PARITY 3:LINKUP TIME 4:FIELD SPACE

Selecting "3: PROTOCOL" on the SET OPTICAL screen calls up the screen shown at left. 1 SERIAL No.:

Switches to the serial number ON/OFF screen.

2 H. PARITY:

Switches to the horizontal parity ON/OFF screen.

3 LINKUP TIME:

Switches to the timeout length screen.

4 FIELD SPACE:

Switches to the space code handling screen.

Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET OPTICAL screen, press the C key.

NOTE

If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.

50

Page 66

Chapter 2. Getting Started the BHT-6000 and System Mode

SET SERIAL No. < OPTICAL > 1:ON

2:OFF

Selecting the "1:SERIAL No." on the SET PROTOCOL menu calls up the screen shown at left. Select whether or not the system should add serial numbers to data blocks, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET H.PARITY < OPTICAL > 1:ON

2:OFF

Selecting the "2:H.PARITY" on the SET PROTOCOL menu calls up the screen shown at left. Select whether or not the system should add a horizontal parity, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET LINKUP TIME < OPTICAL > 1:30 4:120 2:60 5:None 3:90

Selecting the "3:LINKUP TIME" on the SET PROTOCOL menu calls up the screen shown at left. Select the timeout length (in seconds) to be applied when a link is to be established, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET FIELD SPACE < OPTICAL > 1:Ignore 2:Data

Selecting the "4:FIELD SPACE" on the SET PROTOCOL menu calls up the screen shown at left. Select whether space codes in the tail of a data field should be ignored or handled as data, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

51

Page 67

[4.6-2]

Setting the communications parameters for the direct-connect interface

SET CONNECTOR 1:TRANSMIT SPEED 2:PARITY BIT 3:DATA BIT 4:STOP BIT 5:PROTOCOL

Selecting "2:CONNECTOR" on the SET COM menu calls up the screen shown at left. 1 TRANSMIT SPEED:

Switches to the transmission speed screen.

2 PARITY BIT:

Switches to the parity setting screen.

3 DATA BIT:

Switches to the character length screen.

4 STOP BIT:

Switches to the stop bit length screen.

5 PROTOCOL:

Switches to the communications protocol option menu.

Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET COM menu, press the C key.

NOTE

If the BHT-Ir protocol has been selected, the parity bit, character length, and stop bit length settings will be ignored.

(1) Transmission speed screen

SET SPEED < CONNECTOR > 1:1200 4: 9600 2:2400 5:19200 3:4800 6:38400

Selecting "1:TRANSMIT SPEED" on the SET CONNECTOR screen calls up the screen shown at left. Select the desired transmission speed by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET CONNECTOR screen, press the C key.

(2) Parity setting screen

SET PARITY BIT < CONNECTOR > 1:None 2:Odd 3:Even

Selecting "2:PARITY BIT" on the SET CONNECTOR screen calls up the screen shown at left. Select the parity: none, odd or even, by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET CONNECTOR screen, press the C key.

52

Page 68

Chapter 2. Getting Started the BHT-6000 and System Mode

(3)

Character length screen

SET DATA BIT < CONNECTOR >

Selecting "3:DATA BIT" on the SET CONNECTOR screen calls up the screen shown at left.

1:7 bits 2:8 bits

Select the desired character length by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET CONNECTOR screen, press the C key.

(4)

Stop bit length screen

SET STOP BIT < CONNECTOR >

Selecting "4:STOP BIT" on the SET CONNECTOR screen calls up the screen shown at left.

1:1 bit 2:2 bits

Select the desired stop bit length by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET CONNECTOR screen, press the C key.

(5)

Communications protocol option menu

SET PROTOCOL < CONNECTOR > 1:SERIAL No. 2:H.PARITY 3:LINKUP TIME 4:FIELD SPACE

Selecting "5:PROTOCOL" on the SET CONNECTOR screen calls up the screen shown at left. 1 SERIAL No.:

Switches to the serial number ON/OFF screen.

2 H. PARITY:

Switches to the horizontal parity ON/OFF screen.

3 LINKUP TIME:

Switches to the timeout length screen.

4 FIELD SPACE:

Switches to the space code handling screen.

Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET CONNECTOR screen, press the C key.

NOTE

If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.

53

Page 69

SET SERIAL No. < CONNECTOR > 1:ON

2:OFF

Selecting the "1:SERIAL No." on the SET PROTOCOL menu calls up the screen shown at left. Select whether or not the system should add serial numbers to data blocks, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET H.PARITY < CONNECTOR > 1:ON

2:OFF

Selecting the "2:H.PARITY" on the SET PROTOCOL menu calls up the screen shown at left. Select whether or not the system should add a horizontal parity, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET LINKUP TIME < CONNECTOR > 1:30 4:120 2:60 5:None 3:90

Selecting the "3:LINKUP TIME" on the SET PROTOCOL menu calls up the screen shown at left. Select the timeout length (in seconds) to be applied when a link is to be established, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

SET FIELD SPACE < CONNECTOR > 1:Ignore 2:Data

Selecting the "4:FIELD SPACE" on the SET PROTOCOL menu calls up the screen shown at left. Select whether space codes in the tail of a data field should be ignored or handled as data, by using the numerical keys or F5 and F6 keys. Then press the ENT key. To return to the SET PROTOCOL menu, press the C key.

54

Page 70

Chapter 2. Getting Started the BHT-6000 and System Mode

[4.6-3]

Setting the interface port

SET COM PORT 1:BASIC OPT IFC 2:SYSTEM MODE OPT IFC

Selecting the "3:COM PORT" on the SET COM menu calls up the screen shown at left. Reversed is the current setting. 1 BASIC:

Selects the optical or directconnect interface port to be used for user programs written in BHT-BASIC 3.0 (OPEN "COM:" or XFILE statement).

2 SYSTEM MODE:

Selects the optical or directconnect interface port to be used for downloading or uploading files in System Mode.

Select a desired item by using the numerical keys or F5 and F6 keys, and then select a desired setting by using the F7 and F8 keys. To return to the SET COM menu, press the C key.

55

Page 71

[4.6-4]

Setting the communications protocol type

PROTOCOL TYPE 1:BHT Protocol 2:BHT IrProtocol

Selecting the "4:PROTOCOL TYPE" on the SET COM menu calls up the screen shown at left. Reversed is the current setting. 1 BHT Protocol:

Selects the BHT-protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BHT-BASIC 3.0. This protocol should be selected for file transmission with Transfer Utility.

2 BHT IrProtocol:

Selects the BHT-Ir protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BHT-BASIC 3.0. This protocol should be selected for file transmission with Ir-Transfer Utility C.

Select a desired item by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET COM menu, press the C key.

SET ID

00001 >> _

Selecting the "2:BHT IrProtocol" on the PROTOCOL TYPE screen calls up the screen shown at left. Enter the ID number of the BHT-6000 by using the numerical keys, and then press the ENT key. If you do not need to modify the current setting, press the ENT key only.

SET ID

NOTE 00001 >> 65535_

An ID number should be five-digit decimal character string. The setting range is from 00001 to 65535. If the entered value is less than five digits, the ENT key does not become operable.

If you make a wrong entry, press the BS key to delete it and then enter the correct data. To return to the SET COM menu, press the C key.

56