Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 20

Bar Code Handy Terminal BHT-6000 User's Manual: Chapter 2 Getting Started the BHT-6000 and System Mode, pages 52 to 61

Pages 52 to 61 of 178, from Bar Code Handy Terminal BHT-6000 User's Manual

The original document is the PDF (973 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the NipponDenso CU-6002 and Denso CU-6002

Page 52

Chapter 2. Getting Started the BHT-6000 and System Mode

If an error occurs during downloading If some error occurs during downloading, the BHT-6000 beeps three times and shows one of the following screens with the prompt "Retry?": To retry the download, press the 1 and ENT keys; to abort it, press the 2 and ENT keys.

DOWNLOAD FILE (A:) Out of memory !! Retry? 1:Yes2:No

■ Problem The designated memory is insufficient for storing files to be downloaded.

■ Solution Press the 2 key to return to the SYSTEM MENU, then delete unnecessary files in the memory or decrease the size of the file to be downloaded. (Refer to Subsection 2.5.3, [ 7 ] and [ 2 ].)

DOWNLOAD FILE (A:)

■ Problem

File mismatch !!

■ Solution

Retry? 1:Yes2:No

Press the 2 key to return to the SYSTEM MENU and switch to the JIS 1/JIS 2 font menu, from which you download the JIS font file. (Refer to Subsection 2.5.3, [ 9 ].)

DOWNLOAD FILE (A:) Too many files!! Retry? 1:Yes2:No

You attempted to download a JIS font file.

■ Problem The current download will exceed the maximum of forty files in the memory.

■ Solution Press the 2 key to return to the SYSTEM MENU. If you attempted to download more than one file, delete unnecessary files in memory or decrease the number of files to be downloaded. (Refer to Subsection 2.5.3, [ 7 ] and [ 2 ].)

37

Page 53

DOWNLOAD FILE (A:) XXXXXXXX.XXX Communication error !! Retry? 1:Yes2:No

■ Problem Downloading has failed.

■ Solution To retry downloading, press the 1 key. To return to the SYSTEM MENU, press the 2 key. Check the interface port and communications parameters in the SET SYSTEM menu or perform the communications test in the TEST menu. (Refer to Subsection 2.5.3, [4.6] and [5.5].) It is also necessary to check the communications parameters setup of the host computer.

DOWNLOAD FILE (B:) Drive A memory short !! Retry? 1:Yes2:No

■ Problem The RAM is insufficient for copying files stored in the flash ROM.

■ Solution Press the 2 key to return to the SYSTEM MENU, then delete unnecessary files in the RAM.

NOTE

When receiving downloaded files to the flash ROM, the BHT-6000 may copy the files stored in the flash ROM into the RAM. This requires an unused user area of 128 kilobytes in the RAM. If there is no area for copying in the RAM, the error message shown at left will appear.

38

Page 54

Chapter 2. Getting Started the BHT-6000 and System Mode

[ 3 ] Uploading UPLOAD 1:DRIVE A 2:DRIVE B 3:DRIVE A (ALL) 4:DRIVE B (ALL) 5:HT<->HT COPY

⇓

Selecting "3: UPLOAD" on the SYSTEM MENU calls up the screen shown at left. 1 DRIVE A

: Uploads a user program file or data file stored in the RAM.

2 DRIVE B

: Uploads a user program file or data file stored in the flash ROM.

3 DRIVE A (ALL)

: Uploads all of the files stored in the RAM.

4 DRIVE B (ALL)

: Uploads all of the files stored in the flash ROM.

5 HT<->HT COPY : Uploads all of the files, system parameters, and calendar clock data stored in the BHT-6000, to another BHT6000. This function enables copying between the BHT-6000s. At the receiving BHT-6000, select "2: DOWNLOAD" and "3: HT<->HT COPY" in System Mode. For the preparation to be made preceding the start of this function, refer to NOTE given on page 34. Select a desired item by using the numerical keys or F5 and F6 keys, and the selected item becomes reverse-displayed. Then press the ENT key. To return to the SYSTEM MENU, press the C key. In the center of the 2nd line appears the selected uploading type--(A:), (B:), (A:ALL), (B:ALL) or (HT <->HT).

UPLOAD FILE (A:) SAMPLE01.PD3 SAMPLE02.PD3 SAMPLE03.PD3 SAMPLE04.PD3

If you select "1: DRIVE A" or "2: DRIVE B," the screen shown at left will appear, showing all of the program files and data files stored in the selected memory. If you select any other items, this screen will be skipped. The screen at left shows that "1: DRIVE A" has been selected. Use the F5 and F6 keys to move the cursor to the file to be uploaded, then press the ENT key.

39

Page 55

UPLOAD FILE (A:) **************** *NO FILE EXISTS* ****************

If you select any of the "1:DRIVE A" through "4:DRIVE B (ALL)" when no data files are stored in the specified memory, the message shown at left will appear. Pressing the C key returns to the UPLOAD menu.

Upload screens UPLOAD FILE (A:) ** Waiting **

If you select the "1:DRIVE A" or "2:DRIVE B" and choose a file to be uploaded or if you select any of the "3:DRIVE A (ALL)" through "5:HT<->HT COPY," then the screen shown at left will appear. Showing this screen, the BHT-6000 waits for a file(s) to be uploaded.

⇓ UPLOAD FILE (A:) ** Loading **

⇓ UPLOAD FILE (A:) SAMPLE00.PD3 ** Loading ** XXXXX/YYYYY

⇓ UPLOAD FILE (A:) SAMPLE00.PD3 ** Completed ** YYYYY/YYYYY

Upon start of optional Ir-Transfer Utility C, Transfer Utility or equivalent program (upon receipt of an ACK code from the host computer), the BHT6000 displays the screen shown at left. (Refer to the "Ir-Transfer Utility C Guide" or "Transfer Utility Guide.")

While the uploading operation is in progress, the screen shown at left is displayed indicating the file name and the number of sent records/the total number of records. To abort the uploading operation, press the C key. The screen will switch back to the UPLOAD menu. Upon completion of uploading, the number of sent records becomes equal to the total number of records and the beeper beeps once. Press the C key to return to the UPLOAD menu. If you have selected "3: DRIVE A (ALL)," "4: DRIVE B (ALL)," or "5: HT<->HT COPY" on the UPLOAD menu, a sequence of the above screens will be repeated by the number of files to be uploaded.

40

Page 56

Chapter 2. Getting Started the BHT-6000 and System Mode

If an error occurs during uploading If some error occurs during uploading, one of the following screens will appear and the beeper beeps three times. To retry the uploading operation, press the 1 and ENT keys; to abort it, press the 2 and ENT keys.

UPLOAD FILE (A:) SAMPLE00.PD3 File error !!

■ Problem The file you attempted to upload is damaged.

■ Solution

Upload?1:Yes2:No

To upload the damaged file as is, press the 1 key.

UPLOAD FILE (A:) XXXXXXXX.XXX Communication error !! Retry? 1:Yes2:No

■ Problem Uploading has failed.

■ Solution To retry uploading, press the 1 key. To return to the SYSTEM MENU, press the 2 key. Check the interface port and communications parameters in the SET SYSTEM menu or perform the communications test in the TEST menu. (Refer to Subsection 2.5.3, [4.6] and [5.5].) It is also necessary to check the communications parameters setup of the host computer.

41

Page 57

[ 4 ] System Environment Setting SET SYSTEM 1:PROGRAM 6:COM 2:DISPLAY 7:KEY 3:DATE/TIME 4:BARCODE 5:RESUME

Selecting "4: SET SYSTEM" on the SYSTEM MENU calls up the screen shown at left. 1 PROGRAM

: Sets an execution program to be run when the power is turned on.

2 DISPLAY

: Sets the message version (English or Japanese), display font size (standard or small), and system status indication (shift-key icon).

3 DATE/TIME

: Sets the calendar clock (date and time).

4 BARCODE

: Sets the special bar-code scanning parameters (the black-and-white inverted label reading, the touch scanning/long-range scanning, and the decoding level).

5 RESUME

: Sets the resume function.

6 COM

: Sets the communications environments (interface port and communications parameters).

7 KEY

: Defines the functions of the shift key and magic keys.

Select a desired item by using the numerical keys or F5 and F6 keys, and the selected item becomes reverse-displayed. Then press the ENT key. Press the C key to return to the SYSTEM MENU.

42

Page 58

Chapter 2. Getting Started the BHT-6000 and System Mode

[4.1]

Setting an execution program

SET EXEC PROGRAM A:EASYPACK.PD3 A:SAMPLE1.PD3 A:SAMPLE2.PD3 B:SAMPLE3.PD3 B:SAMPLE4.PD3

Selecting "1: PROGRAM" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. Use the F5 and F6 keys to move the cursor to a desired execution program to be run when the power is applied, and then press the ENT key. To return to the SET SYSTEM menu, press the C key. The RAMed files are shown as "A:FILE NAME;" the flash-ROMed files are as "B:FILE NAME."

SET EXEC PROGRAM

If no files program are stored in the memories, the screen shown at left will appear.

**************** *NO FILE EXISTS* ****************

To return to the SET SYSTEM menu, press the C key.

43

Page 59

[4.2]

Setting the message version, display font size, and system status indication

SET DISPLAY 1:MESSAGE Japanese English 2:FONT 8dot 6dot 3:STATUS ON OFF

Selecting "2: DISPLAY" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 MESSAGE : Switches the message version to English or Japanese for the indications and messages on the self diagnosis, LCD contrast, beeper volume, and battery voltage level screens. (The default is the message version that you selected in the initializing sequence.) 2 FONT

: Switches the display font size to be used in application programs to the standard (8-dot) or small (6dot).

3 STATUS

: Turns the system status indication on or off. If it is set to on, the shift-key icon appears as shown below.

Select a desired item by using the numerical keys or the F5 and F6 keys, then select a desired setting by using the F7 and F8 keys. Press the ENT key. To return to the SET SYSTEM menu, press the C key.

REFERENCE

You may turn the system status indication on or off also by using the OUT statement in user programs. Refer to the "BHT-BASIC 3.0 Programmer's Manual."

System Status Indication Turning on the system status indication displays the following icon: Indication

Icon

Shift state of the keys on the keypad

Description Appears when the keys on the keypad are shifted.

44

Page 60

Chapter 2. Getting Started the BHT-6000 and System Mode

[4.3]

Setting the calendar clock

SET DATE/TIME 00/01/01 00:00 _ /

/

:

Selecting "3: DATE/TIME" on the SET SYSTEM menu calls up the screen shown at left. Use the numerical keys to enter the year (only the last two digits), month, day, hour, and minute in this order, and then press the ENT key. If the data is in one digit, add a 0 (zero) preceding the data.

NOTE

For the year, be sure to enter the last two digits of the year. For the hour, enter it in the 24-hour format. If any of the year, month, day, hour, and minute is not entered, the ENT key does not become operable.

⇓

If you make a wrong entry, press the BS key to delete it and then enter the correct data. To return to the SET SYSTEM menu, press the C key.

SET DATE/TIME

[Example] To set 1997, August 19, at 4:00 p.m.

00/01/01 00:00

Press 9 , 7 , 0 , 8 , 1 , 9 , 1 , 6 , 0 , and 0 .

97/08/19 16:00_

⇓ SET DATE/TIME

Press the ENT key to register the above setting.

97/08/19 16:00 _ /

/

:

45

Page 61

[4.4]

Setting the special bar-code scanning parameters

SET BARCODE 1:INVERT ON OFF 2:TOUCH READ ON OFF 3:DECODE LEVEL 3

Selecting "4: BARCODE" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 INVERT

: Activates or deactivates the black-and-white inverted label reading function.

2 TOUCH READ

: Switches to the touch scanning (ON) or long-range scanning (OFF).

3 DECODE LEVEL : Sets the decode level. Select a desired item by using the numerical keys or F5 and F6 keys, and then select a desired setting by using the F7 and F8 keys. To increase the decode level, press the F8 key; to decrease it, press the F7 key. Press the ENT key. To return to the SET SYSTEM menu, press the C key.

Black-and-white inverted label reading function (INVERT) This function makes it possible to read white bars on a black background.

NOTE

Activating this function might increase the frequency of bar-code reading errors. This function can usually be set to OFF.

Touch scanning/long-range scanning (TOUCH READ) You may select touch scanning or long-range scanning. The touch scanning is a method in which you bring the bar-code reading window to a bar code to be scanned. The long-range scanning allows you to read bar codes wider than the readable area of the bar-code reading window by pulling the bar-code reading window away from bar codes. If "TOUCH READ" is set to ON, the reading speed increases in touch scanning. In longrange scanning, however, this setting may decrease the reading speed and efficiency when the ambient illuminance is low or too high. If "TOUCH READ" is set to OFF, the BHT-6000 can scan bar codes irrespective of the ambient illuminance. This setting, therefore, is suitable for long-range scanning. Note that the scanning speed will slightly decrease.

Decode level (DECODE LEVEL) You may set the recognition level. Decreasing the level value increases the bar-code reading efficiency, but the BHT-6000 might misread low-quality bar codes (split or stained). To the contrary, increasing the level value decreases the bar-code reading efficiency, but it precludes almost all possibilities of misreading. The setting range of the level value is from 1 to 9 and the default is 3.

46