The text of a manual · part 10 of 20
Bar Code Handy Terminal BHT-6000 User's Manual: Chapter 2 Getting Started the BHT-6000 and System Mode, pages 72 to 81
Pages 72 to 81 of 178, from Bar Code Handy Terminal BHT-6000 User's Manual
The original document is the PDF (973 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the NipponDenso CU-6002 and Denso CU-6002
Page 72
Chapter 2. Getting Started the BHT-6000 and System Mode
[4.7]
Defining the functions of the shift key and magic keys SET KEY
1:SHIFT KEY 2:M1 KEY 3:M2 KEY
Selecting the "7:KEY" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 SHIFT KEY:
Switches to the shift key definition screen.
2 M1 KEY:
Switches to the M1 key definition screen.
3 M2 KEY:
Switches to the M2 key definition screen.
Select a desired screen by using the numerical keys or F5 and F6 keys, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.
Defining the function of the shift key
SET SHIFT KEY 1:Nonlock 2:Onetime
Selecting the "1:SHIFT KEY" on the SET KEY menu calls up the screen shown at left. Reversed is the current setting. 1 Nonlock:
Shifts the keypad only when the SF key is held down.
2 Onetime:
Shifts only one key pressed immediately after the SF key is pressed. (The following keys will not be shifted.)
Select a desired setting by using the numerical keys or F5 and F6 keys, and then press the ENT key. The screen returns to the SET KEY menu.
57
Page 73
Defining the function of M1 or M2 key
SET M1 KEY 1:Trigger Switch 2:Shift Key 3:Enter Key 4:Backlight Key 5:None
Selecting the "2:M1 KEY" or "3:M2 KEY" on the SET KEY menu calls up the screen as shown at left. (This example appears when the "2:M1 KEY.") Reversed is the current setting. The M1 or M2 key can function as listed below. 1 Trigger Switch:
As the trigger switch.
2 Shift Key:
As the SF key.
3 Enter Key:
As the ENT key.
4 Backlight Key:
As the backlight function on/off key.
5 None:
The key entry will be ignored.
Select a desired setting by using the numerical keys or F5 and F6 keys, and then press the ENT key. The screen returns to the SET KEY menu.
Magic keys M1 and M2 Both M1 and M2 keys are assigned the trigger switch function by default. You can make them function as the SF key, ENT key, or backlight function on/off key. If you define the M1 key as the backlight function on/off key, pressing the M1 key activates or deactivates the backlight function. In user programs, a string data also can be assigned to these magic keys.
NOTE
Both of M1 and M2 keys cannot be assigned the backlight function on/off key. The key defined more recently will act as the backlight function on/off key and one defined earlier will be ignored. That is, if you define the M1 and M2 keys as the backlight function on/off key in this order, the M2 key will work as the backlight function on/off key and the M1 key’s entry will be ignored.
58
Page 74
Chapter 2. Getting Started the BHT-6000 and System Mode
[ 5 ] Testing TEST 1:BARCODE 6:LCD 2:MEMORY 7:KEY 3:BEEPER 8:FILE 4:AGING 5:COMMUNICATION
Selecting "5: TEST" on the SYSTEM MENU calls up the screen shown at left. 1 BARCODE : Selects the bar-code reading test. 2 MEMORY : Selects the RAM read/write test and the address test. 3 BEEPER
: Selects the beeper scale test.
4 AGING
: Selects the aging test.
5 COMMUNICATION : Selects the communications test. 6 LCD
: Selects the LCD and reading confirmation LED tests.
7 KEY
: Selects the key entry & beeper test.
8 FILE
: Selects the file checksum test.
Select a desired setting by using the numerical keys or F5 and F6 keys, and then press the ENT key. The screen returns to the SYSTEM MENU. Reversed is the current setting. To return to the SYSTEM MENU, press the C key.
NOTE
If an error occurs in any of the above tests, contact your nearest dealer.
59
Page 75
[5.1]
Bar-code reading test
TEST BARCODE
Selecting "1: BARCODE" on the TEST menu calls up the screen shown at left. Actually read bar codes with the BHT-6000 and check the read data displayed on the LCD.
⇓ Bar-code type Number of digits of the bar code
TEST BARCODE A 13 4999999999999
Upon completion of bar-code reading, the BHT6000 beeps, turns on the reading confirmation LED in green, and displays the read data together with the bar-code type and the number of data digits. Up to 64-digit data can be shown and the excess will be discarded. To return to the TEST menu, press the C key.
Data
Listed below is a table showing the relationship between the bar-code types and the identifier letters to be displayed on the LCD.
Bar-code Type
ID Letters
EAN-13, UPC-A
A
EAN-8
B
UPC-E
C
Standard 2 of 5 (STF)
H
Interleaved 2 of 5 (ITF)*
I
CODABAR (NW7)
N
CODE39
M
CODE93
L
CODE128
K
* The BHT-6000 can read only those ITF bar codes having 4 digits or more in length.
60
Page 76
Chapter 2. Getting Started the BHT-6000 and System Mode
[5.2]
Memory test
TEST MEMORY ** Testing ** XXXXX/YYYYY
Selecting "2:MEMORY" on the TEST menu calls up the screen shown at left, and then starts writing and reading onto/from all areas of the RAM as well as checking the address. XXXXX: Tested RAM capacity (unit: kilobytes) YYYYY:
TEST MEMORY ** Test NG ** XXXXX/YYYYY Address:hhmmll Write:AA Read:BB
Total RAM capacity (unit: kilobytes)
If any error is detected, the BHT-6000 beeps three times, shows the message as shown at left, and terminates the test. Where, hhmmll: Address where an error has occurred. AA:
Data to write.
BB:
Data read out from the RAM.
To return to the TEST menu, press the C key.
TEST MEMORY ** Test OK ** YYYYY/YYYYY
Upon normal completion of the RAM test, the BHT6000 beeps once, shows the message as shown at left, and returns to the TEST menu.
61
Page 77
[5.3]
Beeper scale test
TEST BEEPER
Selecting "3:BEEPER" on the TEST menu calls up the screen shown at left and makes the beeper sound at three octaves listed below. Upon completion of this test, the BHT-6000 automatically returns to the TEST menu. To stop this test while in progress, turn the power off and on. Scale
[5.4]
Frequency (Hz)
do
523
1046
2093
4186 re
587
1174
2349
- mi
659
1318
2637
- fa
698
1396
2793
- sol
783
1567
3135
- la
880
1760
3520
- ti
987
1975
3951
-
Aging test
TEST AGING DATE
97/01/21
TIME
15:30:00
Selecting "4:AGING" on the TEST menu proceeds to the aging test while showing the current date and time on the LCD. (This test is intended for personnel which check the BHT-6000 in the factory.)
NOTE
Once this test is selected, the automatic powering-off function becomes disabled. Be sure to turn the power off or press the C key to return to the TEST menu.
62
Page 78
Chapter 2. Getting Started the BHT-6000 and System Mode
[5.5]
Communications test
In System Mode, you may test the optical interface port and direct-connect interface port.
■ Preparation for the optical interface test Arrange two BHT-6000s, one as a master station and the other as a slave station (to be tested) with their IR ports facing each other as illustrated below. In this test, the slave BHT-6000 transmits data to the master BHT-6000 and receives the data sent back from the master BHT-6000. Data
Master BHT-6000
Slave BHT-6000 (to be tested)
0.8 m
■ Preparation for the direct-connect interface test Arrange the 3-pole mini stereo plug as illustrated below and connect it to the directconnect interface port on the BHT-6000. SD RD
TEST COM 1:OPTICAL 2:CONNECTOR
Selecting the "5:COMMUNICATION" on the TEST menu calls up the screen shown at left. 1 OPTICAL
: Switches to the MASTER/ SLAVE selection screen for the optical interface test.
2 CONNECTOR : Tests the direct-connect interface port.
63
Page 79
Testing the optical interface port TEST COM < OPTICAL >
Selecting the "1:OPTICAL" on the TEST COM menu calls up the screen shown at left.
1:SLAVE 2:MASTER
At the slave BHT-6000 to be tested, select the "1:SLAVE" and at the master BHT-6000, select the "2:MASTER."
TEST COM < OPTICAL >
During the test, the screen shown at left is displayed.
** Testing **
TEST COM < OPTICAL >
If any error occurs, the tested slave BHT-6000 beeps three times and shows the screen at left.
** Test NG ** (XX)
In parentheses are error codes which have the following meanings: (X X) 1: The received data is different from the sent data. 2: A timeout has occurred during standby for data reception. 1: 2400 bps 2: 9600 bps 3: 115200 bps Press the C key to return to the TEST COM menu. The master BHT-6000 will automatically return to the TEST COM menu after 10 seconds from the occurrence of an error.
TEST COM < OPTICAL > ** Test OK **
Upon normal completion of the test, the tested slave BHT-6000 beeps once and shows the screen at left. Press the C key to return to the TEST COM menu. The master BHT-6000 will automatically return to the TEST COM menu.
64
Page 80
Chapter 2. Getting Started the BHT-6000 and System Mode
Testing the direct-connect interface port TEST COM < CONNECTOR >
Selecting the "2:CONNECTOR" on the TEST COM menu displays the screen shown at left and then starts testing the direct-connect interface port.
** Testing **
TEST COM < CONNECTOR >
If any error occurs, the BHT-6000 beeps three times and shows the screen at left.
** Test NG ** (XX)
In parentheses are error codes which have the following meanings: (X X) 1: The received data is different from the sent data. 2: A timeout has occurred during standby for data reception. 1: 300 bps 2: 38400 bps Press the C key to return to the TEST COM menu.
TEST COM < CONNECTOR >
Upon normal completion of the test, the BHT-6000 beeps once and shows the screen at left.
** Test OK **
Press the C key to return to the TEST COM menu.
65
Page 81
[5.6]
LCD and reading confirmation LED tests Selecting "6:LCD" on the TEST menu calls up the test pattern shown at left on the LCD and turns on the reading confirmation LED in green. Each time the ENT key is pressed, the screen shifts to the next test pattern. To return to the previous screen, press the BS key.
BS key
⇑
⇓
ENT key
To stop this test while in progress, press the C key. As shown at left, everything disappear and the reading confirmation LED lights in red.
BS key
⇑
⇓
ENT key
The checker pattern shown at left appears and the reading confirmation LED goes off.
BS key
⇑
⇓
ENT key
The checker pattern is reversed.
BS key
⇑
⇓
ENT key
An outline with a width of one dot appears.
66