Page 41
Procedure to Enter into Set-up Mode FM 4602 and FM 4603 models only 1.
Power on the printer.
2.
When the “ READY” message is displayed on the LCD, press [PAUSE] and the [CANCEL] buttons simultaneously.
Next Value
Next Feature
Enter Value
Press to Enter / Exit Setup Mode
Figure 24 - Entering into Set-up Mode 3.
Press [PAUSE] button to scroll to the feature that you want to change.
4.
Press [FEED] button to scroll to the desired value of the displayed feature.
5.
Once the desired value is displayed, press [CANCEL] button to save it. After pressing the [CANCEL] button an * should appear in the last column. The * is used to designate the stored value in non-volatile memory (E2PROM).
6.
Press both [PAUSE] + [CANCEL] buttons at the same time, to return to normal mode.
Note: Do not enter set-up mode while the printer is printing or while the host is sending data.
40
User's Guide
Page 42
Set-up Mode Selection Items Item
Range
CUT/PEEL POS (mm)
+ 015 to + 015
0 mm
Controls cut and peeling position.
PRINT OFFSET (mm)
+ 015 to - 008
0 mm
Controls start vertical print position. Positive value only.
TPH VER OFFS(mm)
+ 003 to - 003
0 mm
RECOVERY PRINT
ENABLE DISABLE MORE THAN 10, 5 to 7 mm, 8 to 9 mm. NORMAL (~4”), MORE (<3”), MORE (<2”)
ENABLE
NORMAL (~4”)
2”, 3” and 4”(inches) stand for the label width. Setting proper width can avoid jam.
TYPE I, TYPE II
TYPE I
Enable the type of cutter mechanism is installed
1
GAP HEIGHT
2
CUTTER ROTATION
2
CUTTER TYPE
Factory Default
Remarks
MORE THAN 10 mm
COMPRESSED FLASH NO NO COMPRESSION, COMPRESSION COMPRESSED WIN CON LEN (mm) 0 to 254 mm 0 mm This takes effect only when you run under Windows with bundled printer driver and use continuous media. BASE SPEED (IPS)
0 to 4 IPS
0 IPS
COUNTER ON LCD
ENABLED, DISABLED REFLECTIVE SEE-THROUGH
ENABLED REFLECTIVE
Select the proper type by the media characteristics. Do calibration before printing.
2
CUTTER SIGNAL
CHECKED, IGNORED
CHECKED
For general media, set it to “CHECKED” except for thick media.
BACKFEED
DISABLE, ENABLE
DISABLE
This feature enables a manual Present function. It can be disabled by a software command.
3
010 to 040
012
This is the distance the printer will move the form to a Presentation position.
MEDIA SENS. TYPE
BACK DISTNCE(mm)
1 2 3
This is for the PPLB emulation only. When you choose TLP2642/3642 driver the speed is limited under 2 ips.
Displayed only when Switch 4 is on. Displayed only when Switch 3 enabled Displayed only when the BACKFEED feature is enabled. User's Guide
41
Page 43
Notes: 1. To verify that a feature has been properly changed, cycle power on the printer. 2. Make sure the settings you desire has an * character by the value. 3. When changing the Media Sensor Type feature (Reflective and See-through); be aware that the See-through sensor is 1 mm to the left of the Reflective sensor. 4. If graphics are stored with compression in the flashboard, do not use them under noncompression mode .
42
User's Guide
Page 44
Setting Display Language The printer can display messages, error condition, and feature menus in multiple languages. This capability does not affect the printed text. The printer's LCD display supports six languages: English, French, German, Italian, Spanish and Portuguese To change the currently displayed language 1. Press and hold the PAUSE and CANCEL buttons at the same time. 2. Hold both buttons for about 5 seconds. 3. When the buttons are released the following is displayed LANGUAGE ENGLISH
*
4. Press FEED button to scroll the next available language. 5. Press CANCEL button to select the language for your need. 6. Pressing PAUSE or PAUSE+CANCEL buttons exits setting and enters normal mode. Item LANGUAGE
Range ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH, PORTUGUESE.
Factory Default ENGLISH
User's Guide
43
Page 45
Back Panel The rear panel includes -
An 8-bit DIP switch (FM4602/FM4603 models only)
-
A 36-pin Centronics connector
-
A 9-pin serial connector
-
A PS/2 keyboard connector (FM4602/FM4603 only)
-
A power switch and power connector
Caution: On the FM4402 model there is a voltage selection switch for selecting the appropriate line voltage. Make sure to set the correct voltage (115V or 230V) before powering up the printer, otherwise the printer will be damaged.
44
User's Guide
Page 46
FM 4602/4603 Back Panel Switches Parallel Port PS/2, Keyboard Interface Serial Port
External Label Feed Slot Cover
Power Switch
AC Inlet Receptacle
Model Number and Serial number
Figure 25 - Back Panel FM4602/FM4603
FM 4402 Models Parallel Port External Label Feed Slot Cover
Serial Port
Voltage Selection Switch Model Number and Serial number
Power Switch AC Inlet Receptacle
Figure 26 - Back Panel FM4402
User's Guide
45
Page 47
Back Panel Switches (FM4602 and FM4603 models only)
Back Panel Switches are only available on FM4602 and FM4603. Any change in switch position is not registered until Power is cycled. Standard Switch Settings Switch Number
Function
Position Description setting
1
Thermal Transfer Ribbon
ON
Ribbon is installed. Thermal transfer mode. Enables end-of-ribbon detection. If end-of-ribbon occurs the RIBBON and READY indicators will blink.
OFF
Ribbon is not installed. Direct thermal.
ON
PPLA: Alternate (printable) control code set.
2
Euro Mark
PPLB: Euro dollar symbol is used to replace the character ‘_’. OFF
PPLA: Standard control set. PPLB: No Euro symbol.
3 4 5
46
User's Guide
Cutter Gap Size
ON
Cutter is installed.
OFF
Cutter is not installed.
ON
The gap length is more than 4 mm.
OFF
Media with normal gap or continuous media.
ON
Peeler is installed.
OFF
Peeler is not installed.
Page 48
Switches 6, 7 and 8 are used to determine the printer's Baud Rate.
6
7
8 Baud rate
OFF
OFF
OFF
9600 (default)
ON
OFF
OFF
2400
OFF
ON
OFF
4800
ON
ON
OFF
19200
OFF
OFF
ON
38400
ON
ON
ON
Special Setting: 9600 and for barcode reader
Special Switch Settings: Switch number
1
2
3
4
5
6
7
8
Sets Baud Rate to 9600 for a Bar Code Reader
N/A
N/A
N/A
N/A
N/A
On
On
On
Clears Objects from the Flash that are used with PPLB emulation. **
N/A
N/A
On
N/A
On
N/A
N/A
N/A
Special Condition
N/A - Switch position has not function in the condition.
Note: Make sure to set switch 3 and 5 their original positions.
User's Guide
47
Page 49
PS/2 Keyboard I/F (FM4602 and FM4603 models only) The special keyboard interface connector is available on the FM4602/FM4603 models. This is for PS/2 keyboard or barcode reader with keyboard wedge. When this interface is used, using the Centronics or RS-232 communication ports is discouraged. Use of the PS/2 keyboard interface may only be operated in stand-alone mode. The printer can automatically detect the keyboard. But if you use a barcode reader you should set switches 6, 7 and 8 to the ON positions. Before a keyboard or a barcode reader is connected make sure that the printer is set for the following configuration. -
Make sure that the printer has the PPLB emulation installed.
-
Make the desired form is download to the printer.
-
Make sure that a PS/2 keyboard or barcode reader with KB wedge is available. (Refer to the Appendix for Stand-Alone Operation for further information.)
48
User's Guide
Page 50
COMMAND QUICK REFERENCE This section lists all software commands of the printer. For more information please refer to the Programmer’s Manual.
Command Set for PPLA The following commands are for Printer Programming Language A. Note: In this quick reference all variable data is represented in Italics. System Setting Commands These commands will cause the related parameters to be saved in the non-volatile memory, E2PROM. The parameters will be stored unless they are changed by another command, or reset from the panel. Command
Description
<STX>KI4n
Media empty check
<STX>KI7n
Set ribbon mode
<STX>KI8n
Set baud rate
<STX>KI;n
Control Code types
<STX>KXnnnn
Set continuous label length
<STX>KI<m
Set symbol set for ASD smooth font set
Parameter n : ‘0’ - disable, ‘1’ - enable. n : ‘0’ – DT, ‘1’ – TT.
Factory default Enabled TT with ribbon (for FM4402)
n : ‘0’ – 9600, 9600 baud. ‘1’ – 600, (for FM4402) ‘2’ – 2400, ‘3’ – 19200, ‘4’ – 4800, ‘5’ – 38400, ‘6’ – 1200, ‘7’ – 9600. n : '0' - selects standard control For FM4402 codes. '1' - Select alternate control codes nnnn : a 4-digit number, in mm m : ‘0’ - USASCII, ‘1’ - United Kingdom, ‘2’ - Spanish, ‘3’ - Swedish, ‘4’ - French, ‘5’ - German, ‘6’ - Italian, ‘7’ - Danish/Norwegian.
0 for USASCII
User's Guide
49