Page 31
Self Test Pattern for FM4402 PPLB
Figure 22 - Self Test FM4402 PPLB
30
User's Guide
Page 32
Resetting the Printer to Factory Default Settings To reset the printer to its factory defaults after certain commands have been sent or settings changed: 1. Power off the printer. 2. Press and hold the CANCEL/RESET button. 3. Power on the printer. 4. As the printer turns on the printer will: FM 4402: All the LED's will come on with the Ribbon LED will begin flashing. FM 4602/4603: The printer will display “E2PROM RESET …” on the LCD and the READY LED will blink. 5. When the “READY” LED stops blinking and is continually on the printer's initialization is completed. On the FM4602 and FM4603 models the Display will indicated "READY" on the LCD. 6. The following parameters reset to Factory Defaults. -
Label parameters Heat (Darkness) Speed Symbol set (language) Others for specific emulation
Notes: 1. All settings stored in non-volatile E2PROM are not erased when the printer looses power. 2. Mechanical positions of the Switches on the back of FM 4602 and 4603 are not changed with this procedure. 3. It is necessary to do a Label Sensor Calibration following a Reset. 4. The label count printed during the Self-Test can not be reset.
User's Guide
31
Page 33
This is a blank page
32
User's Guide
Page 34
PANEL OPERATION Front Panel The front panel includes -
3 LED indicators (READY, MEDIA and RIBBON)
-
3 buttons (FEED, PAUSE and CANCEL)
-
LCD display (for FM4602 and FM4603 models only)
Figure 23 - Fastmark 4000 Series Front Panel
User's Guide
33
Page 35
LED Indicators There are three LED indicators on the front panel, “READY”, “MEDIA” and “RIBBON”. These indicators display the present status of the printer. X READY
The Ready LED indicates the following conditions: ON - The printer's powered is on. Off
- The printer's power is off.
Blinking - Error condition (see Troubleshooting section for details) X MEDIA
X RIBBON
The Media LED indicates the following conditions: ON - Media is installed and ready for Normal operation. Off - The printer's power is off. Blinking - Media Out condition. This condition only occurs following a media motion request. The Ribbon LED indicates the following conditions: ON - The printer is set for Thermal Transfer mode and the printer contains a Thermal Transfer Ribbon. OFF - The printer is set for Direct Thermal Mode. Blinking - The printer is set for Thermal Transfer mode and the ribbon is not moving or at end of life. This condition only occurs following a media motion request.
34
User's Guide
Page 36
Buttons Depending upon the printer model and current mode, the Front Panel buttons serve multiple functions. Refer to the following tables for their specific functions. Pressed and held down during Power UP Upon completion of the desired function the printer will go into a READY condition. Button m FEED
Function The printer performs an internal Self-Test and prints a Configuration Report. The FM4602/4603 models display "SELF TESTING" on the LCD display. m PAUSE The printer will do a Label Sensor Calibration test on the current loaded media. The FM4602/4603 models display "CALIBRATION" on the LCD display. m CANCEL The printer will reset the Non-Volatile memory (E2PROM) back to factory defaults. The FM4602/4603 models display "E2PROM RESET" on the LCD display.
User's Guide
35
Page 37
Pressed during normal operation Button m FEED m PAUSE
Function The printer will Feed a one label. The printer will begin blinking the READY LED. If printing the printer will STOP printing, and the READY LED will blink. If pressed a second time the printer will resume normal operation. The FM4602/4603 models will blink the READY LED and display PAUSE on the LCD display while in the Paused condition. m CANCEL The printer will Stop printing and delete any further information in the printer's buffer. The user must realign the media by pressing the FEED button, following this function. The FM4602/4603 models will blink the READY LED and display CANCEL on the LCD display while in the Paused condition. Pressed for Special functions The following functions are only available on the FM4602 and FM 4603 models. Button Function m PAUSE Enter into the printer's Setup menu. m CANCEL See the Front Panel Setup Menu section for more information. m PAUSE If held down for more than 5 seconds, the printer will allow m CANCEL Language Selection. See the Setting the Display Language section for more information. Note: Both buttons must be pressed at the same time for the above special functions.
36
User's Guide
Page 38
LCD Display (FM4602 and 4603 models only) For the model FM4602/FM4603 the front panel is equipped with a 2 row by 16 character LCD display. The basic function of the display is: -
Display the printer status
-
Display the printer settings
-
Display's prompts requesting input data from a keyboard or barcode reader.
Standard Printer After power on the following message is displayed on the LCD READY (203,PPLA)
The first parameter is either 203 or 300. It stands for the printer's resolution. FM4602 will display 203 FM4603 will display 300 The second parameter indicates the emulation (printer language), PPLA or PPLB.
With Keyboard Option installed If a keyboard is plugged in, the following message is displayed on the LCD
READY (203,PPLA) <ESC> FOR KEYBD
User's Guide
37
Page 39
With Barcode Reader Option If a barcode reader is connected and switches 6 through 8 are in the ON positions, the displayed message will be. READY (203,PPLA) WITH B.C. READER
Abnormal Conditions If any abnormal condition occurs the related message will be displayed. For example: RIBBON OUT
38
User's Guide
Page 40
Front Panel Set-up Menu FM 4602 and FM 4603 models only The Set-up menu is a list of printer features that affect the basic operation of the printer. These are functions that can not normally be selected using software commands. Value settings that are changed using the keypad are stored into E2PROM and are retained when power is cycled. Value settings that are changed using software commands are temporary changes and are not retained when power is cycled. LCD and Button functionality in Set-up mode Normal Mode Buttons
Function
PAUSE + CANCEL
Enters into set-up mode. If in set-up mode, pressing these two keys will exit Set-up mode and return to normal mode.
Setup Mode Pressing this button will scroll to the next value of the displayed feature. Pressing this button will scroll to the next Feature.
FEED PAUSE CANCEL
Pressing this key will select the displayed value. It will also save that value into non-volatile (E2PROM) memory.
LCD Displayed Information Below is an example of a typical displayed Feature. BAS E 0 0 0
S P EED
( I PS) *
Feature name: BASE SPEED (IPS) Feature Value: 000 Stored indicator: *
User's Guide
39