Interaction Commands Such commands only apply to the serial port and allow the host to understand the status and configuration of the printer. Command <SOH># <SOH>A

<SOH>B <SOH>E

<SOH>F

Description

Response Contents of the Response from printer Reset Yes <XOFF><XON>T Send a readable status Yes <8 bytes, Y/N> <CR> string byte 1 : Y - printer busy byte 2 : Y - paper out byte 3 : Y - ribbon out byte 4 : N (always) byte 5 : Y - printing byte 6 : Y - printer paused byte 7 : Y - label presented byte 8 : N (always) Toggle pause No condition Send the number of Yes e. g. labels to be printed 0000<CR> no label left to be printed Send status byte Yes n<CR> Same as <SOH>A, except bits 1 to 8 corresponds to bytes 1 to 8 of <SOH>A.

Notes: 1.

Control codes for the printer commands. Symbol XON XOFF STX SOH ESC LF CR

Code (hexadecimal) 11H 13H 02H 01H 1BH 0AH 0DH

2. There is no space code in each command.

50

User's Guide

Page 52

System Level Commands Command

Description

<STX>a

Enable page/job echo characters

<STX>cxxxx

Set continuous paper length and disable edge sensor

<STX>Dxxxxxxx

Memory dump**

<STX>Exxxx

Set copy count for stored label

<STX>e

Enable edge sensor

<STX>F

Feed a page

<STX>fxxx

Back feed from top position

<STX>G

Print stored label

<STX>I

Download graphics

Remarks xxxxxxx : memory address in HEX value either PCX, BMP, PCX or HEX format

<STX>J

Set pause for each label

<STX>j

Cancel pause

<STX>KQ

System configuration details

<STX>L

Enter label formatting state

<STX>Mxxxx

Set maximum label length

<STX>m

Set measurement in metric

<STX>n

Set measurement in inches

<STX>Oxxxx

Set start of print position

<STX>P

Enable data dump

<STX>Q

Clear memory (fonts & graphics)

<STX>r

Select reflective sensor

<STX>Sn

Set feed rate for motor

<STX>T

Print test pattern

<STX>Vn

Set Cutter or Peel and Present configuration n : ‘1’ - enable Cutter, n : ‘A’, ‘B’ or ‘C’

‘4’ - enable Peel and Present <STX>v

Printer version information

<STX>Wn

Graphics/fonts/labels and memory status details

<STX>x

Release file from printer memory n : ‘G’, ‘F’ or ‘L’. through RS232

User's Guide

51

Page 53

Formatting Commands Command

Description

:xxxx

Set cut amount

An

Set print mode n : ‘1’- exclusive, ‘2’ - transparent

Cxxxx

Set horizontal offset cxx

Set cut amount

Dwh

Set pixel width and height

E

Form feed and return to system level command mode

G

Store previous data to global register

<STX>Sn

Retrieve from global register. n : global register ID

Hxx

Set heating value, xx = 01 to 20

M

Toggle the mirror mode m

Set measurement in metric n

Set measurement in inches

Pn

Set print speed. n = ’A’, ‘B’, or ‘C’ **

Qxxxx

Set copy count

Rxxxx

Set vertical offset r<n..n>

Retrieve label data from printer buffer. <n..n> : label name sm<n..n>

Save label data to printer buffer. m : memory module, <n..n> : label name

Txx

Set end-of-line code, xx : hex value z

Change slash zero to normal zero (0).

+xx

Make auto increment for numeric or alphanumeric,

>xx xx : count

-xx

Make auto decrement for numeric or alphanumeric,

<xx xx : count

^xx

Set count amount, xx : count

Notes:

**

:

52

The formatting and editing commands should be grouped together, leaded by <STX>L and ended by E command.

The parameter range is from ‘A’ to ‘K’ (1 to 6 ips) for the model FM4602/FM4603, and for model FM4402 it is from ‘A’ to 'E' (1 to 4 ips).

User's Guide

Page 54

Editing Commands Command structure

Command function

Rthveeeyyyyxxxx<string><CR>

Printing text and bar codes

Components of command

Description

Variables

R print direction

‘1’,’2’,’3’ or ‘4’ (rotation)

t:

object type

‘0’ ~ ‘9’ and ‘:’ (fonts) **, ‘A’ ~ ‘Z’ and ‘a’ ~ ‘z’ (bar codes), ‘X’ (lines or boxes), ‘Y’ (graphics).

h width multiplier

‘1’ to ‘9’ and ‘A’ to ’ O’. ‘0’ stands for default.

v height multiplier

‘1’ to ‘9’ and ‘A’ to ’ O’, ‘0’ stands for default.

eee bar code height

This is ignored for box, line and graphics. It represents point size for font ‘9’ and symbol set for Courier font**.

yyyy

Y coordinate xxxx

X coordinate

<string> depends on object types

User's Guide

53

Page 55

Object

Command Structure

Description

L : line

Lwwwhhh www : width,

(if t is ‘X’) L : line hhh : height. lwwwwhhhh

(if t is ‘X’) B : box wwww : width, hhhh : height.

Baaabbbcccddd

(if t is ‘X’)

aaa : horizontal width bbb : vertical height ccc : thickness of top and bottom edges ddd : thickness of left and right bars

B : box baaaavvvvccccdddd

(if t is ‘X’)

aaaa : horizontal width vvvv : vertical height cccc : thickness of top and bottom edges dddd : thickness of left and right bars

Bar code bar code data

The bar codes (and human readable text) will be printed according to the selected bar code type (‘A’ ~ ‘Z’ or ‘a’ ~ ‘z’).

text data

Such text data will be printed according to the selected font (‘0’ ~ ‘9’).

file name

If t is ‘Y’ and the file was downloaded by <STX>I command.

(if t is in the range ‘A’ to ‘Z’ or ‘a’ to ‘z’) Text (if t is in the range ‘0’ to ‘9’)

Note: **Model FM4603 does not include Courier fonts.

54

User's Guide

Page 56

Font Downloading Commands Such commands are only used for soft fonts with PCL format. Command

Description

ESC*c###D assign the soft fonts ID number (### : 100 ~ 999)

ESC)s###W download font descriptor (### : length of font descriptor)

ESC*c###E set character code (### : 1 ~ 255)

ESC(s###W download character descriptor and image (### : length of character descriptor and image)

User's Guide

55

Page 57

This is a blank page.

56

User's Guide

Page 58

Command Set for PPLB The following commands are for Printer Programming Language B. All PPLB commands must be ended with <LF> or <CR>+<LF> codes. No spaces are allowed between parameters and leading command character. Command

Description

Parameter

Ax,y,rot,font,hm,vm,nr,string

Print text.

font: 1 to 5 for internal font and A to Z for soft font.

Bx,y,rot,bar,nw,ww,v,hum,string

Print Bar Code. nw: width of narrow bar: barcode selection bar ww: width of wide bar v: bar code height hum : B for printing readable code and N for disabling.

bx,y,type,[…]

Print 2D Bar Code type: M for Maxi code and P for PDF 417

Ccn,dn,just,step,string

Counter declaration cn: counter index dn: digit number just: L,R,C and N for field justification step: step value

Dp1

Heat setting p1: density, 0 to 15

EI

Print soft font names

EKstring

Delete soft font

ESstring, ….

Download soft font

FE

End form store

FI

Print form names

FKstring

Delete form string: form name or “*” to delete all forms

FSstring

Execute form string: form name

FSstring

Save form string: form name

GGx,y,string

Print graphics string: graphic name

GI

Print graphic list

GKstring

Delete graphics string: graphic name or “*” to delete all graphics

GMstring,size<LF>…

Store graphics string: graphic name size: graphic size in byte

Ip1,p2,001

Select symbol set** p1: 7 or 8 data bits p2: symbol set string: soft font name or “*” to delete all soft fonts

User's Guide

57

Page 59

Command

Description

JB

Disable back feed**

JF

Enable back feed**

LEx,y,hlen,vlen

Line draw by exclusive

Parameter hlen: horizontal length vlen: vertical length

LOx,y,hlen,vlen

Line draw by OR

LWx,y,hlen,vlen

Draw white line

N

Clear frame buffer

O[,C][,N][,D]

Select options

Pp1[,p2]

Print label p1: label set number p2: copy number of each label

PAp1[,p2]

Print automatic

Qp1,p2[,+p3]

Set label and gap length** p1: label length p2: gap length p3: offset length qw

Set label width**

Rx,y

Set origin point**

Sp1

Set print speed

U

Print configuration

UN

Disable Error Report

US

Enable Error Report

Vvn,dn,just,string

Define variable w: label width p1: speed value, 4 to 6 vn: variable index dn: digit number just: L,R,C and N for field justification

Xx,y,thick,ex,ey

Draw box

ZT

Set print direction ex, ey: end position thick: line thickness

ZB ZS ZN ?

58

ZB: print from bottom Enable/disable storeto-Flash++ Download variables or counters

User's Guide

ZS: print from top power-on default is ZN(disabled)

Page 60

Command

Description

Parameter d1,hadj

Set horizontal position hadj: adjustment in dots. adjustment** d2,hadj

Set horizontal position same as d1, except it is no saved to adjustment E2PROM

Notes: 1.

x and y represent horizontal and vertical coordinate values.

2.

hm and vm stand for horizontal and vertical multipliers.

3.

rot is the rotation direction, its value is from 0 to 3.

4.

nr is either N for normal printing or R for reverse printing.

5.

string is bracket by double quote marks, e.g. “text”.

6.

**

7.

ZS takes effect only if flash memory board is installed.

Commands will cause the printer to save parameters to permanent storage (E2PROM).