Communications (continued) Menu Item HEAT COMMAND ENABLED
Details Determines how a host software Heat command is handled, where: Processes commands normally.
DISABLED
Ignores commands; instead, Heat is controlled via the menu setting; see Section 4.2.3.
SPEED COMMANDS
Determines how host software Print, Feed, Reverse, and Slew commands are handled, where:
ENABLED DISABLED TOF SENSING COMMANDS ENABLED DISABLED SYMBOL SET COMMAND ENABLED DISABLED CNTRL-CODES (DATA) ENABLED DISABLED STX-V SW SETTINGS ENABLED DISABLED
I-Class
Processes commands normally. Ignores commands; instead, the speeds are controlled via the menu setting; see Section 4.2.3. Determines how host software Gap, Continuous, and Reflective commands are handled, where: Processes commands normally. Ignores commands; instead, Sensor Type is controlled via the menu setting; see Section 4.2.3. Determines how host Single and Double Symbol Set commands are handled, where: Processes commands normally. Ignores commands; instead, the Symbol Set selection is controlled via the menu setting; see Section 4.2.5. Determines how host software Control Codes are handled, where: Processes commands normally. Controls the setting via the menu; see CONTROL CODES, above. Determines how a host software option enable command is handled, where: Processes commands normally. Controls the settings via the menu; see Section 4.2.4.
51
Page 62
Communications (continued) Menu Item MAX LENGTH COMMAND ENABLED
Details Determines how a host software Maximum Label Length (<STX>M) command is handled, where: Processes commands normally.
DISABLED
Controls the setting via the menu; see Section 4.2.2.
OPTION FEEDBACK
Allows feedback characters from an optional device to be returned to the host device, in the format of <A;B;C;D;E;F>[CR], where: A - Is the device type: R = RFID; and, S = Linear Scanner B - Is the status: C = entire label complete; F = faulted (failed) label; and, U = unknown C - Is the number of expected reads, given in two characters. D - Is the number of good reads, given in two characters. E - Is the internal Job and Sub Job Identifier, given in four characters each. F - Is the data read, delimited with semicolons (;) if multiple reads.
DISABLED SCANNER
Reports Linear Scanner data.
RFID HEX
Reports RFID data in hexadecimal format.
RFID ASCII
Reports RFID data in an ASCII format.
PROCESS SOH (DATA) DISABLED ENABLED
52
Reports no data.
Determines the response to an Immediate Command (e.g., Get Status, Module Storage, etc.), where: Processes commands normally. Interrupts operations upon SOH receipt to process the command.
I-Class
Page 63
4.2.7 Diagnostics The Diagnostics menu contains testing functions: Menu Item
Details
HEX DUMP MODE
Allows raw code received from the host to print, where:
DISABLED
Executes commands and prints label formats normally.
ENABLED OPTIONS TESTING TEST PRESENT SENSOR PERFORM TEST 1 TIME TEST CUTTER PERFORM TEST 1 TIME TEST GPIO MONITOR GPIO INPUT
Prints received data without processing; see Section 6.2. Allows testing of printer options, where: Tests the Present Sensor (and Peel & Present Mechanism) on demand function, where: Selects the number of LABEL PRESENTED tests (1, 10, or 100) to perform, and then displays the results. Tests the Cutter, where: Selects the number of cuts (1, 10, or 100) to perform, and then displays the results. Tests the General Purpose Input Output interface, where: Displays the logic values for Start of Print (SOP), Feed, Pause, and Reprint (REPRT) signal inputs. (The values given below are examples only.) SOP 0
FEED 0
PAUSE 0
REPRT 0
Note: Unconnected lines may assume a zero or one. MONITOR GPIO OUTPUT
Allows toggling and displays the logic values for End of Print (EP), Ribbon Low (RL), Service Required (SR), Media Out (MO), Ribbon Out (RO), Data Ready (DR), and Output Fault (OF) signal outputs. (The values given below are examples only.) EP 1
RL 1
SR 0
MO 1
RO 1
DR 0
OF 0
Note: To change an output signal, cursor over the displayed state to select and then toggle it, except Data Ready which cannot be toggled.
I-Class
53
Page 64
Diagnostics (continued) Menu Item
Details
LOOPBACK
Not Supported
PRINT SIGNAL INFO
Prints signal names, pin assignments, settings, and current states for reference. GPIO SIGNAL INFO WED 11:04AM 24MAR2003 CARD ID#1
OUTPUT SIGNALS
INPUT SIGNALS
END OF PRINT PIN# 6 LOW PULSE CURRENT LEVEL 1
START OF PRINT PIN# 8 ACTIVE HIGH CURRENT LEVEL 0
RIBBON LOW PIN# 5 ACTIVE LOW CURRENT LEVEL 1
BACKUP LABEL PIN# 7 DISABLED CURRENT LEVEL 0
SERVICE REQUIRED PIN# 4 ACTIVE LOW CURRENT LEVEL 0 MEDIA OUT PIN# 3 ACTIVE LOW CURRENT LEVEL 1 RIBBON OUT PIN# 2 ACTIVE LOW CURRENT LEVEL 1
TEST SCANNER ALIGNMENT TEST
Reads a bar code then displays the decoded data, the code type and scan count, repeating.
SCAN TEST
Reads a bar code then displays the decoded data, the code type and scan count, non-repeating.
TEST RFID
Tests RFID, where:
TAG DATA
Reads the data encoded on the RFID chip.
DEVICE VERSION
Displays the type and version of the encoding device.
TAG ID – HF ONLY
Reads and displays the High Frequency Tag ID number.
PRINT TEST RATE (min) 000 (0 - 120)
54
Tests the Linear Scanner, where:
Allows a label-to-label delay (0 - 120 minutes) when printing test label batches, where: Is the selected delay interval, in minutes.
I-Class
Page 65
Diagnostics (continued) Menu Item SENSOR READINGS THR TRAN RIBM 24V 127 159 093 175
Details Displays A-D sensor values (0 – 255), where: Are the sensor readings, where:
• THR = Printhead thermistor sensor; • TRAN = Media sensor when set to Gap or Continuous, or REFL when to Reflective;
PS HD 000 254
RANK 000
• • • • •
RIBM = Ribbon sensor; 24V = 24 VDC sensor; PS = Present sensor; HD = Printhead position sensor; and, RANK = Printhead ranking resistor.
Note: Readings provided here are examples only. RIBBON SENSOR LIMITS RIBBON ADC LOW HIGH 070 104
Displays the values from the ribbon sensor (when equipped with the thermal transfer option), where: Are the sensor readings (actual values will vary).
4.2.8 MCL Options The MCL Options menu contains alternate operating selections: Menu Item MCL OPTIONS MCL AT POWER-UP DISABLED
I-Class
Allows the optional MCL (Macro Command Language) tool suite to accept peripheral input data, where: Allows MCL operation to begin when the printer is turned ON, where: No MCL operation.
MCL LINK MODE
Starts MCL in Link Mode.
MCL PROGRAM MODE
Starts MCL in Program Mode.
START MCL
Note:
Details
Starts MCL after exiting the menu.
Consult your MCL provider for details regarding operation and support.
55
Page 66
4.3 The Test Menu The TEST Key accesses six resident format selections that are printed at selected heat and speed settings (see Section 4.1.4 for printing details).
Notes: (1) With the exception of the Configuration Label, all test labels require full width media to capture the entire format. (2) During a test, press the
Key or the
Key to stop printing.
(3) Use PRINT TEST RATE (Section 4.2.7) to delay printing.
4.3.1 Print Quality Label The Print Quality Label can be used to ensure conformance and visual aesthetics.
4.3.2 Configuration Label The Configuration Label provides database information, as detailed in Section 4.2.
CONFIGURATION
SERIAL PORT A: BAUD RATE:
APPLICATION VERSION:
PROTOCOL:
MCL Version: 1.20.02-126 BOOT LOADER:
PARITY:
4308-TB10-020312-001
83-2284-11E4 11.054 07/07/2008
83-2269-11A 11.01 10/02/2007
UNLOCKED: *NONE
FPGA: *
Notes:
(1) Label contents vary with application version, model, and options. (2) Use at least 2 inch (51mm) wide media and set the Label Width accordingly (see Section 4.2.2). (3) Bulleted items indicate host changes not yet saved.
56
COMMUNICATIONS
TUE 09:09 AM 29JUL2008 PRINTER KEY:
MACO:
NOT SET
MACR: 00-90-c9-01-d0-84
SYSTEM INFORMATION PRINT BUFFER SIZE: 100 in.
FLASH SIZE: 2 MB
RAM TEST: PASS
OPTIONAL LANGUAGES: FRANCIAS.DLN ITALIANO.DLN DEUTSCH.DLN ESPANOL.DLN
9600 BPS BOTH
NONE
DATA BITS: 8
STOP BITS: 1
SERIAL PORT B: NOT INSTALLED SERIAL PORT C: NOT INSTALLED SERIAL PORT D: NOT INSTALLED USB PORT: NOT INSTALLED PARALLEL PORT A: PORT DIRECTION: UNI-DIRECTIONAL
PARALLEL PORT A: NOT INSTALLED:
CONFI
I-Class
Page 67
4.3.3 Ribbon Test Label The Quick Ribbon Test Label can be used to verify thermal transfer functions.
4.3.4 Validation Label The Validation Label can be used to verify print quality.
4.3.5 Print Last Label The Print Last Label function reprints the most recent test label, format received from the host, or format recalled from a memory module. Note:
If a job was cancelled or if power was removed since the last job and the request for this label, no reprint will occur.
4.3.6 User Defined Label The User-Defined Label allows a template to be populated by variable data (via the printer's control panel or a USB QWERTY keyboard). The template is a stored label format, where fields delimited by the "&" become variable. The printer will prompt the user to enter these variable field data. (For example, the stored label format could contain the data 19131423443&ENTER NAME. Afterward, when recalled from memory, the printer's display will indicate the variable field: ENTER NAME.) Notes:
(1) Variable data can be any part of the DPL format - font ID, rotation, etc. (2) No error checking will be performed.
I-Class
57
Page 68
58
I-Class
Page 69
5
Operating, Adjusting and Maintaining the Printer
5.1 Displayed Messages During operation the printer (when not in Menu or Test Mode) displays several types of information:
•
Prompts and Condition Messages (see Section 5.1.1); and,
•
Fault and Warning Messages (see Section 6.1.2).
5.1.1 Prompts and Condition Messages Prompts are alerts to required actions, while Condition Messages are indicators of an operational state. Prompts and Condition Messages Displayed Message
Description
Action
ACCESS DENIED
The password used to access the secured menu was incorrect.
Enter the correct password.
CALIBRATION COMPLETE
The FEED Key was pressed and held.
Allow the calibration to complete.
CANCEL BATCH ENTER KEY = YES
Press ENTER to cancel The CANCEL or TEST Key was all remaining labels in pressed during a multiple label job. the job.
CANCEL REPRINT? ENTER KEY = YES!
The CANCEL or TEST Key was pressed during a fault. (See FAULT HANDLING / VOID AND RETRY, Section 4.2.5.)
Press ENTER to cancel the reprint.
CLEARING FAULTS
The FEED Key was pressed following a fault and now the printer is attempting to clear the condition.
No action is required.
I-Class
59
Page 70
Prompts and Condition Messages (continued) Displayed Message
Description
Action
DISPLAY CONTRAST
The MENU Key is being pressed and held, and now the LCD contrast is being adjusted.
Release the MENU Key when the desired contrast is achieved.
DMXNET INITIALIZING
The network card is initializing, a normal condition following powerup or a reset.
No action is required. Depending upon the settings, it may take a few minutes.
The selected option or feature cannot be found.
Verify that the option or feature is correctly installed. If so, call for service.
The PAUSE Key was pressed (or PAUSE MODE is enabled, see Section 4.2.5) and now the printer is in a paused condition.
Press PAUSE.
PRINTHEAD CLEANING
The TEST Key was pressed and held, or CLEAN HEAD NOW was selected, and now printhead cleaning is in progress.
No action is required.
READY
The printer is waiting to receive label formats, downloads, etc.
Send a label format, download, etc.
NOT INSTALLED
PAUSED
60
REMOVE LABEL!!
The Present Sensor (or Peel and Present Mechanism) is enabled and Remove the label. a label awaits removal.
REMOVE RIBBON PRESS ANY KEY
The TEST Key was pressed and held, or CLEAN HEAD NOW was selected, but ribbon is installed.
Remove ribbon and press any key to proceed.
SUCCESSFUL PRESS ANY KEY
The selected operation was successfully completed.
Press any key to continue.