Page 51

System Settings (continued) Menu Item AUTO

Details Identifies then activates the appropriate emulation parser for the data. Note:

COLUMN EMULATION XXX DOTS (XXX - XXX)

Allows the column dot count to be adjusted, where: Selects the number of dots per inch (or mm) in which to print the format, reducing it from right to left; see Appendix B for range and Section 7.1 for dot size. Note:

ROW EMULATION XXX DOTS

(XXX - XXX)

Selects the number of dots per inch (or mm) in which to print the format, reducing or enlarging it from top to bottom; see Appendix B for range and Section 7.1 for dot size. No adjustment occurs at the default setting.

Allows SOP functions with backward compatibility when printing legacy model label formats, where: Note:

DISABLED

No adjustment occurs at the default setting.

Allows the row dot count to be adjusted, where:

Note: SOP EMULATION

Correct identification can be dependant upon the HOST SETTINGS / HOST TIMEOUT (see Section 4.2.6). Also, extraneous characters may, in some cases, render the data unrecognizable, thus requiring manual selection of the mode.

The printer may automatically feed labels to setup the print position.

Uses the normal position.

110 (PRODPLUS)

Emulates the Prodigy Plus® position.

220 (ALLEGRO)

Emulates the Allegro® position.

250 (PRODIGY)

Emulates the Prodigy™ position.

BACK AFTER PRINT

I-Class

Determines label movement timing when a cutter, present sensor, peel and present, or GPIO option is enabled, where:

41

Page 52

System Settings (continued) Menu Item MODE

Repositions media, where:

DISABLED

Moves media only when the next label is ready to print, minimizing edge curling.

ENABLED

BACKUP DELAY 000

Details

Moves media according to BACKUP DELAY timing after a cut, cleared sensor, or SOP signal to allow fastest throughput. (1/50s)

(0 – 255)

FONT EMULATION STANDARD FONTS

Determines repositioning timing, where: Is the specified lapse (in fiftieths of a second) between new format processing and label retraction. Allows font substitution of internal fonts, where: Prints using a standard (internal) font; see the Class Series 2 Programmer’s Manual.

CGTIMES

Prints using the CG Times font.

USER ID S50

Prints using a downloaded font.

LABEL STORE STATE & FIELDS FIELDS ONLY MENU LANGUAGE ♦

Determines the data content when retrieving stored label formats, where: Recalls the printer state (i.e., heat, speeds, etc.) and the formatting commands for the stored label. Recalls the formatting commands for the stored label. Selects the display language for the menu and Configuration Label, where: Note: Only resident languages will be selectable; see Appendix C.

42

ENGLISH

Enables English.

FRANCAIS

Enables French.

ITALIANO

Enables Italian.

DEUTSCH

Enables German.

ESPANOL

Enables Spanish.

I-Class

Page 53

System Settings (continued) Menu Item FAULT HANDLING ♦ LEVEL STANDARD

VOID AND RETRY

Details Determines the label disposition and user action if a fault occurs, where: Sets the printer response upon declaration of a fault, where: Stops printing and declares a fault. Then, following correction of the problem, the FEED Key must be pressed to clear the fault and reprint the label in process. Actions depend upon the RETRY COUNT:

• If the count has not been exceeded, VOID is printed on the failed label and reprinting automatically occurs;

• If the count has been exceeded, printing stops and a fault message is displayed. Then, following correction of the problem, the FEED Key must be pressed to clear the fault and reprint the label in process; or,

• If the CANCEL Key is pressed, reprinting is optional: press NO to reprint; or, press YES to cancel the reprint (and press YES again to cancel the batch.)

Note: DELAYED SCAN FAULT

Linear Scanner or RFID required.

Increases throughput when bar codes reside near the trailing edge of the label (in the direction of FEED). Notes: (1) Linear Scanner or RFID required. (2) If unreadable, the fault will occur after the next label prints; (3) The label immediately following a faulted label is not scanned for errors; and, (4) VOID AND RETRY and REPRINT are automatically disabled; the job can only be cancelled.

VOID RETRY & CONT.

VOID is printed on a faulted label, with reprint attempts occurring automatically, until the RETRY COUNT has been exceeded and then that label will be skipped (discarded) and printing will continue to the next label in queue. Note:

NO REPRINT

I-Class

Linear Scanner or RFID required.

Printing stops and a fault message is displayed. Following correction of the problem, the FEED Key must be pressed to clear the fault.

43

Page 54

System Settings (continued) Menu Item VOID DISTANCE 0.50in

(10 – 2.00)

Details Sets the distance to print VOID on a faulted label, where: Is the distance, measured from the trailing edge, which establishes the text size. Note: VOID will not be printed if insufficient text space exists or if the fault occurred after printing completed. Also, the text can be customized; see the Class Series 2 Programmer’s Manual.

RETRY COUNT 1

(0 - 3)

Sets the number of printing attempts before declaring a fault, where: Is the count. Note: Greater than 1 (one) counts are valid only when Linear Scanner or RFID equipped.

BACKFEED ON CLEAR

Determines positioning after a fault is cleared, where:

DISABLED

No label positioning occurs, as the location is assumed correct. Note: If reloading, the user must place media at the SOP position.

ENABLED SCL FONT BOLD FACTOR 01

(1 – 36)

Automatically positions the label. Sets a scalable font boldfacing amount, where: Is the setting, based on an incrementing scale where one (01) is minimum.

4.2.6 Communications The Communications menu contains interface port and host control functions: Menu Item SERIAL PORT A ♦ BAUD RATE

44

Details Controls the RS-232 communications settings for Serial Port A, where: Sets the serial communication rate, where:

I-Class

Page 55

Communications (continued) Menu Item 9600 BPS 19200 BPS 28800 BPS 38400 BPS 57600 BPS 115000 BPS 1200 BPS 2400 BPS 4800 BPS PROTOCOL BOTH

Details

Is the speed in Bits Per Second.

Sets the data flow control (handshaking) method. Uses XON/XOFF and CTS/DTR flow control.

SOFTWARE

XON/XOFF

HARDWARE

CTS/DTR

NONE

Flow control is not used.

PARITY NONE

Sets word parity, where: Uses parity.

ODD

Uses odd parity.

EVEN

Uses even parity.

DATA BITS 8 (7 - 8) STOP BITS 1 (1 - 2) SERIAL PORT B ♦

Sets Word length, where: Is the number of bits in the word. Sets the number of stop bits, where: Is the stop bit count. Controls the RS-232 communications settings for optional Serial Port B; see SERIAL PORT A. Note:

SERIAL PORT C ♦

Controls the RS-232 communications settings for optional Serial Port C; see SERIAL PORT A. Note:

I-Class

The maximum baud is 38.4K BPS.

The maximum baud is 38.4K BPS.

45

Page 56

Communications (continued) Menu Item SERIAL PORT D ♦

Details Controls the RS-232 communications settings for optional Serial Port D; see SERIAL PORT A. Note: The maximum baud is 38.4K BPS.

PARALLEL PORT A ♦ PORT DIRECTION UNIDIRECTIONAL

Controls the communications settings for Parallel Port A, where: Allows data return from the printer, where: Returns no data; communication is one-way.

BIDIRECTIONAL

Returns data (compliant back-channel operation).

PARALLEL PORT B ♦

Controls the communications settings for optional Parallel Port B; see PARALLEL PORT A. Note: The default setting is BIDIRECTIONAL.

NIC ADAPTER ♦ QUICK SETUP

Controls the communications settings for the network interface, where: Note: Only when equipped with DMXNetII or DMXrfNetII. Selects settings to configure basic Wired or WiFi operations, where:

WIRED DHCP WIRED DHCP? CANCEL KEY = YES WLAN UNSECURED WLAN UNSECURED? CANCEL KEY = YES WLAN ADHOC

46

Selects Wired operation, where: Returns the NIC Adapter to defaults then sets Wired Discovery to “Enable” and Wireless to “Disable.” Selects WiFi operation, where: Returns the NIC Adapter default values then sets Discovery to “Enable,” SSID to “Any,” and WLAN network type to “Infrastructure.” Selects the DMXrfNetII default parameters, where:

I-Class

Page 57

Communications (continued) Menu Item WLAN ADHOC? CANCEL KEY = YES

Details Restores the WiFi defaults and initiates infrastructure mode with an SSID of “Any.” All existing access point associations will be deleted then established with the closest available. (Useful when moving the printer to a geographically distant location.) Note: Press the ESC Key to exit the menu item without changing the current settings.

SET FACTORY DEFAULTS SET DEFAULTS? CANCEL KEY = YES

WLAN

Returns the factory-programmed values, where: Restores the default settings. Note: Press the ESC Key to exit the menu item without changing the current settings. Controls the communications settings for the optional DMXrfNetII Card, where:

MODE

Selects between Wired or WiFi operation, where:

ENABLED

Enables the WiFi interface.

DISABLED

Enables the Wired interface.

BSS ADDRESS

Specifies the WiFi bridge module’s static IP address. Note: If DHCP is ENABLED, this parameter will be ignored.

192.168.010.001 SIGNAL READINGS IP ADDRESS 192.168.010.026 SUBNET MASK 255.255.255.000 GATEWAY 192.168.010.026

I-Class

Is the address in standard octet format. Displays the signal and noise ratios for the WLAN. Specifies the static IP Address; where: Is the address in standard octet format. Specifies the static Subnet Mask Address, where: Is the address in standard octet format. Specifies the network Gateway Address, where: Is the address in standard octet format.

47

Page 58

Communications (continued) Menu Item SNMPTRAP DESTINATION 000.000.000.000

Details Specifies the SNMP Trap Address, where: Is the address in standard octet format where SNMP traps will be sent when SNMP service is installed on your receiver. Note:

IP DISCOVERY ENABLED

When zeroed, no traps are sent.

Controls IP Address discovery, where: Broadcasts over the network at startup to receive addresses from the responsible server. Manual modifications to IP Address, Subnet Mask, or Gateway are not allowed; and, if no server is found, the specified static value will be used.

WARNING

DISABLED SNMP

Uses the stored static IP, Subnet Mask, and / or Gateway Address. Allows management protocols, where:

ENABLED DISABLED ADVANCED TELNET

Sends messages to SNMP-compliant devices. Sends no messages. Sets advanced networking functions and parameters, where: Sets Telnet protocol to transfer data, where:

ENABLED

Allows Telnet.

DISABLED

Disables Telnet.

FTP

48

A server assigned IP address takes precedence over any static address stored in the interface.

Sets File Transfer Protocol to transfer data, where: ENABLED

Allows FTP.

DISABLED

Disables FTP.

I-Class

Page 59

Communications (continued) Menu Item MTU

Details Sets the Maximum Transmission Unit packet size, where:

01500 (512 - 65515) GRATUITOUS ARP 0000 (0 - 2048) PORT NUMBER 09100 (1 - 65535) DUPLEX CAPABILITY AUTO-NEGOTIATE

Is the packet size, in bytes. Sets the Address Resolution Protocol notification rate, where: Is the time, in minutes. Sets the network communications port, where: Is the Port Number. Sets the communication capability for the Wired network, where: Automatically selects the best type.

100BASET HALF

Selects 100 Mb half duplex (in both directions, one way at a time) operation.

100BASET FULL

Selects 100 Mb full duplex (in both directions, simultaneously) operation.

10BASET HALF

Selects 10 Mb half duplex (in both directions, one way at a time) operation.

10BASET FULL

Selects 10 Mb full duplex (in both directions, simultaneously) operation.

ADVERTISE CAPABILITY AUTOMATIC ALL CAPABILITIES NETWORK REPORT

Transmits the printer’s communication capability for the Wired network, where: Advertises the DUPLEX CAPABILITY set value. Advertises all possible values for DUPLEX CAPABILITY. Prints a network status report (see example below): NETWORK REPORT

CURRENT PRINTER INFO MACO: 00:0D:70:0B:8B:B9 IP ADDRESS: 192.168.10.26 SUBNET MASK: 255.255.255.0 GATEWAY: 192.168.10.26 DHCP: ENABLED SNMP: ENABLED PORT NUMBER: 9100 NETBIOS NAME: DMX_000000

WLAN MODULE

MODULE FW VERSION: 4.3.0.24 RADIO FW VERSION: 1.1.1.111.8.4.0.145 PORT STATUS: CONNECTED: ADHOC SSID: any MACR: 00:90:C9:01:D0:64 BSS ADDRESS: PROVIDED BY DHCP

I-Class

49

Page 60

Communications (continued) Menu Item

Details

SET FACTORY DEFAULTS

Returns the NIC to factory-programmed values, where:

SET FACTORY DEFAULTS? Restores the default settings. CANCEL KEY = YES Note: Press the ESC Key to exit the menu item without changing the current settings. HOST SETTINGS

Sets host communication parameters; where:

HOST TIMEOUT 10 SEC

Sets the period that an interface port can be idle before timeout occurs, where: (1 - 60)

CONTROL CODES ♦ STANDARD CODES

ALTERNATE CODES

ALTERNATE CODES 2

CUSTOM CODES SOH STX CR CNTBY 5E 7E 0D 40 FEEDBACK CHARACTERS DISABLED ENABLED ESC SEQUENCES ENABLED DISABLED

Is the time (in seconds) when downloads timeout, and that must elapse before alternate port or alternate parser processing can occur. Allows changes to the software command interpretation controls, where: Sets the following command interpretation codes: Hex 01 = SOH command; Hex 02 = STX command; countby = ^; Hex 1B = ESC; Hex 0x0D = Carriage Return Sets the following command interpretation codes: Hex 5E = SOH command; Hex 7E = STX command; countby = @; Hex 1B = ESC; Hex 0x0D = Carriage Return Sets the following command interpretation codes: Hex 5E = SOH command; Hex 7E = STX command; countby = @; Hex 1B = ESC; Hex 0x7C = Carriage Return Sets the command interpretation codes as needed, where: Are the codes according to your definitions. Allows the return of printer codes, where: Does not send feedback characters. Sends the host a Hex 1E (RS) after each label and a Hex 1F (US) after each label batch successfully prints. Allows data containing invalid ESC control code sequences to be processed, where: Processes commands normally. Ignores ESC sequences during processing (since some systems send a “banner” to the printer). Note: Bitmapped font downloads are disabled.

50

I-Class