Page 41
Printer Options (continued) Menu Item RFID
Controls the RFID operation, where:
RFID MODULE
Sets the mode of RFID operation, where:
DISABLED
Disables RFID.
HF
Selects the Securakey option.
UHF CLASS 1
Selects the Alien option.
UHF MULTI-PROTOCOL
Selects the UHF cross-platform option.
RFID POSITION 1.10in
(110 - 4.00)
HF SETTINGS
AFI VALUE
Is the type to be encoded.
Sets the Application Family Identifier value, where: (HEX)
AFI LOCK
Is the value (00 - FF). Locks the AFI value, where:
DISABLED ENABLED DSFID VALUE 00
Is the inlay location, as referenced from the leading edge of the tag moving in the direction of print.
Selects the tag type, where:
ISO 15693 TI PHILIPS ST LRI512 ST LRI64
00
Sets the RFID encoding position, where:
Sets the HF RFID encoding settings, where:
TAG TYPE
I-Class
Details
(HEX)
Is not protected. Is write-protected. Sets the Data Storage Format Identifier value, where: Is the value (00 - FF).
31
Page 42
Printer Options (continued) Menu Item
Details
DSFID LOCK
Locks the DSFID value, where: Is not protected.
DISABLED ENABLED
Is write-protected.
EAS VALUE 00
Selects the Electronic Article Surveillance value, where: Is the value (00 - FF).
(HEX)
AUDIO INDICATOR
N/A
ERASE ON FAULT
Allows tag data erasure when errors are detected, where: Keeps data.
DISABLED ENABLED
Erases bad data.
UHF SETTINGS
Sets the UHF RFID encoding settings, where:
TAG TYPE
Selects the tag type, where:
GEN 2 EPC 0 EPC 0+ MATRICS EPC 0+ IMPINJ EPC 1 UCODE EPC 1.19 EM 4022/4222 TAG DATA SIZE
Sets the tag data size, where: Selects 96 bits.
96-BIT 64-BIT
Selects 64 bits.
POWER ADJUST (dBMs) 000
32
Is the type to be encoded.
(-04
004)
Adjusts the applied power, where: Is the power level, in decibels.
I-Class
Page 43
Printer Options (continued) Menu Item KILL CODE
Code to permanently deactivate the tag, where:
00 00 00 00 ACCESS CODE 00 00 00 00 GEN 2 LOCK ACTION NONE
Is the code, in the form B3, B2, B1, B0. Code to protect tag memory contents, where: Is the code, in the form B3, B2, B1, B0. Sets the lock for Gen 2 tags, where: Does not lock the tag.
PERMALOCK
Locks data permanently.
PWD-READ/WRITE
Locks data with password-protection for writing data.
BOTH
Allows both Permalock and PWD-Lock to be used.
PAD/TRUNC. EPC DATA
DISABLED
Allows padding or truncating of data with nulls (represented as “00”) in order to fit the selected EPC Tag Data Size, where: Does not pad or truncate data.
LEADING
Adds nulls to the front (left) of the data if less than the size, or cuts the data if greater.
TRAILING
Adds nulls to the end (right) of the data if less than the size, or cuts the data if greater.
LOCK CODE (ALIEN HW) 00
(HEX)
LOCK AFTER WRITE DISABLED ENABLED
I-Class
Details
Sets the lock code for Alien Gen 2 tags, where: Is the code (00 - FF). Locks the tag after programming, where: No lock occurs. Locks the tag.
33
Page 44
Printer Options (continued) Menu Item RETRY ATTEMPTS 3
(0 - 9)
Details Sets the number of retry attempts, where: Is the retry count before a fault is declared.
AUTO DETECT TAG
Allows the printer to establish the tag to transducer distance setting. CALIBRATING RFID will appear as media is scanned for the tag location. Upon completion, the media will be retracted to the TOF position with the positioning results (along with a brief SUCCESS or FAILURE message).
SET DEFAULTS
Allows the RFID default values to be restored, where:
YES
Restores the default settings.
NO
Exits the menu item without changing the current settings.
GPIO PORT GPIO DEVICE APPLICATOR
Controls the GPIO operation, where: Sets the GPIO option to work with a specific device type, where: Enables parameters for related label applicator functions:
• Completion upon last SOP, de-asserts Data Ready (DRDY);
• FEED allowed at any time; and, • DRDY upon PAUSE. APPLICATOR2
Enables parameters for alternate label applicator functions:
• Completion upon 1 msec. overlap of Data Ready (DRDY) and End of Print (EOP);
• DRDY signal end inhibits FEED; and, • De-asserts DRDY upon PAUSE or FAULT.
34
BARCODE VERIFIER
Enables the GPIO Port to work with a bar code verifier.
DISABLED
Disables the option.
I-Class
Page 45
Printer Options (continued) Menu Item START OF PRINT ACTIVE HIGH
Selects the type of input signal required to initiate printing, where: Triggers printing with a high signal.
EDGE
Triggers printing with a signal edge transition.
LOW PULSE
Triggers printing with a low pulse.
HIGH PULSE
Triggers printing with a high pulse.
ACTIVE LOW
Triggers printing with a low signal.
END OF PRINT
Sets the type of output signal generated to indicate End of Print (EOP), where:
LOW PULSE
Outputs a low pulse upon completion.
HIGH PULSE
Outputs a high pulse upon completion.
ACTIVE LOW
Outputs a logic low upon completion.
ACTIVE HIGH
Outputs a logic high upon completion.
RIBBON LOW
Sets the low ribbon signal (as determined by RIBBON LOW OPTIONS; see Section 4.2.2), where:
ACTIVE LOW
Outputs a logic low when the roll reaches the setting.
ACTIVE HIGH
Outputs a logic high when the roll reaches the setting.
SLEW ENABLE
I-Class
Details
Selects the type of input signal required to initiate label slew, where:
STANDARD
Triggers slew with a low signal.
LOW PULSE
Triggers slew with a low pulse.
HIGH PULSE
Triggers slew with a high pulse.
ACTIVE LOW
Triggers slew with a low signal.
ACTIVE HIGH
Triggers slew with a high signal.
35
Page 46
Printer Options (continued) Menu Item BACKUP LABEL
DISABLED
Details Positions a presented label for printing (provided the PRESENT DISTANCE setting is greater than zero), where: Disables backup positioning.
ACTIVE LOW
Positions the label when a logic low is received.
ACTIVE HIGH
Positions the label when a logic high is received.
ERR ON PAUSE (APP2)
Sets the output when a service required fault occurs, where:
ENABLED
Enables the output signal.
DISABLED
Disables the output signal.
4.2.5 System Settings The System Settings menu contains operating, control, and formatting functions: Menu Item CONFIGURATION FILE
Details Controls the creation, storage, and recall of printer configuration files (see Appendix D), where:
RESTORE AS CURRENT
Lists the files available, and then after selection reconfigures the printer according to that file.
SAVE SETTING AS
Saves the effective configuration of the printer to a named file of up to nineteen characters.
DELETE FILE
Lists the files available, and then after selection, removes that file from memory. Note:
FACTORY SETTING FILE
NONE
36
A currently activated file cannot be deleted.
Lists the files available and then after selection that file will be restored whenever a Level One reset is performed; see Section 5.3.2. Is the currently selected file.
I-Class
Page 47
System Settings (continued) Menu Item INTERNAL MODULE D 1024 K (XXX - XXXX) DEFAULT MODULE D SCALEABLE FONT CACHE 0312 K (100 - 5120) SINGLE BYTE SYMBOLS
PC–850 MULTILINGUAL DOUBLE BYTE SYMBOLS
UNICODE
Details Allocates a number of 1KB memory blocks for internal Memory Module D; where: Is the memory allocation; see Appendix A for the memory ranges, types, and availability. Designates the memory module for storage when no other location is specified; where: Is the module; see Appendix A for availability. Configures the number of 1KB memory blocks for the scaleable font engine; where: Is the memory allocation; see Appendix A for availability. Selects from the 66 available code pages used for single byte fonts (unless otherwise specified in DPL); where: Is the selected code page; for details see the Class Series 2 Programmer’s Manual. Selects the code page (see the Class Series 2 Programmer’s Manual) used for the ILPC option (unless otherwise specified), where: Selects Unicode (including Korean).
GB
Selects Government Bureau Industry Standard, Chinese (PRC).
BIG 5
Selects Taiwan encoded.
JIS
Selects Japanese Industry Standard.
SHIFT JIS
Selects Shift Japanese Industry Standard.
EUC
Selects Extended UNIX Code.
TIME AND DATE SET HOUR 06:30AM 01JAN2000
I-Class
Allows the user to set the time and date; where: Enters the information for the time and date fields. Note:
Time and date retention (after power removal) requires the Real Time Clock function; see GPI/O Multi-Expansion CCA, Section 1.1.2.
37
Page 48
System Settings (continued) Menu Item MEDIA COUNTERS
Details Provides a recorded count of inches printed and time; where:
ABSOLUTE COUNTER
Shows the total number of inches printed and the set date. (Non-resettable)
RESETTABLE COUNTER
Shows the number of inches printed and the last reset date.
RESET COUNTER
Returns the RESETTABLE COUNTER to zero.
PRINT CONFIGURATION
Prints a Configuration Label of current database information where items denoted with the section (§) and bullet (•) symbol indicate changes not yet saved.
CONFIGURATION LEVEL
Displays the hardware and software feature level of the printer, where:
PRINTER KEY
Identifies the unique key number of the printer, in the form vvvv-wwxx-yyyyyy-zzz Where: vvvv
–
Represents the printer model number.
wwxx
–
Represents the hardware and software levels, where: ww – Represents the main logic card type: PA = CCA 51-2178-XX; or TB = CCA 51-2301-XX xx – Represents the software feature level: 10 = Standard DPL 11 = 4208 20 = Internal CG Times Font yyyyyy zzz
38
– Is a manufacturing date code. – Is a unique time stamp.
APPLICATION VERSION
Displays the level, version number, and date of the application firmware.
BOOT LOADER
Displays the Boot Loader version level and date.
UPGRADE PRINTER CODE 000000
Upgrades the printer to the corresponding feature level. (Authorization required.)
I-Class
Page 49
System Settings (continued) Menu Item
Details
UNLOCK FEATURE 000000
Unlocks a corresponding feature with the entry of the correct code.
SET FACTORY DEFAULTS
Returns the printer settings to the factory-programmed values or the Factory Setting File values, where:
SET FACTORY DEFAULT? CANCEL KEY = YES
Overwrites the current configuration and restores the default configuration ( ), or if selected the Factory Setting File. Otherwise, press the ESC Key to keep the current configuration. Note:
FORMAT ATTRIBUTES
A reset will occur and, if no Factory Setting File is used, all settings returned except CUSTOM ADJUSTMENTS and calibrations.
Defines the way overlapping text, bar codes, and graphics are printed, where:
XOR
Does not print intersecting areas, for example:
OPAQUE
Overwrites intersecting areas with those last formatted, for example:
TRANSPARENT
Prints intersecting areas, for example:
LABEL ROTATION DISABLED ENABLED IMAGING MODE ♦ MULTIPLE LABEL
Allows the label format to be rotated 180 degrees, where: Prints formats without rotation. Prints flipped formats. Determines the process used to format labels, where: Formats multiple images, as memory permits, to achieve the fastest throughput. Note:
SINGLE LABEL PAUSE MODE DISABLED ENABLED
I-Class
Time stamps will indicate the moment of imaging rather than printing.
Formats an image only after a previous format has been printed to achieve the most accurate time stamps. Allows controlled interactive printing, where: Prints labels without pausing. Requires the user to press the PAUSE Key to print each label.
39
Page 50
System Settings (continued) Menu Item PEEL MODE DISABLED ENABLED SECURITY ♦ SELECT SECURITY
Details Allows the SOP signal to initiate (via GPIO option) the feeding of the labels, where: Feeds regardless of SOP. Feeds only when SOP is received. Allows menu password protection, where: Enables or disables the security feature, where: Note:
DISABLED
The default password must be changed to activate.
Allows entry.
SECURE MENU
Sets a password requirement for menu entry.
MENU AND TEST
Sets a password requirement for menu and test entries.
MODIFY PASSWORD MODIFY PASSWORD? CANCEL KEY = YES
Modifies the four-digit password required when security is enabled, where: Enters the password (after confirmation); otherwise, press the ESC Key to keep the current password. Note:
UNITS OF MEASURE IMPERIAL METRIC
The default password is 0000.
Sets the measurement standard for the printer, where: Uses inches. Uses millimeters and centimeters.
INPUT MODE
Defines the type of processing that occurs when data is received, where:
DPL
Processes data for standard DPL printing; see the Class Series 2 Programmer’s Manual.
LINE
Processes data for template (Line Mode) printing; see the Class Series 2 Programmer’s Manual.
40