Page 41

Printer Options (continued) Menu Item RFID

Controls the RFID operation, where:

RFID MODULE

Sets the mode of RFID operation, where:

DISABLED

Disables RFID.

HF

Selects the Securakey option.

UHF CLASS 1

Selects the Alien option.

UHF MULTI-PROTOCOL

Selects the UHF cross-platform option.

RFID POSITION 1.10in

(110 - 4.00)

HF SETTINGS

AFI VALUE

Is the type to be encoded.

Sets the Application Family Identifier value, where: (HEX)

AFI LOCK

Is the value (00 - FF). Locks the AFI value, where:

DISABLED ENABLED DSFID VALUE 00

Is the inlay location, as referenced from the leading edge of the tag moving in the direction of print.

Selects the tag type, where:

ISO 15693 TI PHILIPS ST LRI512 ST LRI64

00

Sets the RFID encoding position, where:

Sets the HF RFID encoding settings, where:

TAG TYPE

I-Class

Details

(HEX)

Is not protected. Is write-protected. Sets the Data Storage Format Identifier value, where: Is the value (00 - FF).

31

Page 42

Printer Options (continued) Menu Item

Details

DSFID LOCK

Locks the DSFID value, where: Is not protected.

DISABLED ENABLED

Is write-protected.

EAS VALUE 00

Selects the Electronic Article Surveillance value, where: Is the value (00 - FF).

(HEX)

AUDIO INDICATOR

N/A

ERASE ON FAULT

Allows tag data erasure when errors are detected, where: Keeps data.

DISABLED ENABLED

Erases bad data.

UHF SETTINGS

Sets the UHF RFID encoding settings, where:

TAG TYPE

Selects the tag type, where:

GEN 2 EPC 0 EPC 0+ MATRICS EPC 0+ IMPINJ EPC 1 UCODE EPC 1.19 EM 4022/4222 TAG DATA SIZE

Sets the tag data size, where: Selects 96 bits.

96-BIT 64-BIT

Selects 64 bits.

POWER ADJUST (dBMs) 000

32

Is the type to be encoded.

(-04

004)

Adjusts the applied power, where: Is the power level, in decibels.

I-Class

Page 43

Printer Options (continued) Menu Item KILL CODE

Code to permanently deactivate the tag, where:

00 00 00 00 ACCESS CODE 00 00 00 00 GEN 2 LOCK ACTION NONE

Is the code, in the form B3, B2, B1, B0. Code to protect tag memory contents, where: Is the code, in the form B3, B2, B1, B0. Sets the lock for Gen 2 tags, where: Does not lock the tag.

PERMALOCK

Locks data permanently.

PWD-READ/WRITE

Locks data with password-protection for writing data.

BOTH

Allows both Permalock and PWD-Lock to be used.

PAD/TRUNC. EPC DATA

DISABLED

Allows padding or truncating of data with nulls (represented as “00”) in order to fit the selected EPC Tag Data Size, where: Does not pad or truncate data.

LEADING

Adds nulls to the front (left) of the data if less than the size, or cuts the data if greater.

TRAILING

Adds nulls to the end (right) of the data if less than the size, or cuts the data if greater.

LOCK CODE (ALIEN HW) 00

(HEX)

LOCK AFTER WRITE DISABLED ENABLED

I-Class

Details

Sets the lock code for Alien Gen 2 tags, where: Is the code (00 - FF). Locks the tag after programming, where: No lock occurs. Locks the tag.

33

Page 44

Printer Options (continued) Menu Item RETRY ATTEMPTS 3

(0 - 9)

Details Sets the number of retry attempts, where: Is the retry count before a fault is declared.

AUTO DETECT TAG

Allows the printer to establish the tag to transducer distance setting. CALIBRATING RFID will appear as media is scanned for the tag location. Upon completion, the media will be retracted to the TOF position with the positioning results (along with a brief SUCCESS or FAILURE message).

SET DEFAULTS

Allows the RFID default values to be restored, where:

YES

Restores the default settings.

NO

Exits the menu item without changing the current settings.

GPIO PORT GPIO DEVICE APPLICATOR

Controls the GPIO operation, where: Sets the GPIO option to work with a specific device type, where: Enables parameters for related label applicator functions:

• Completion upon last SOP, de-asserts Data Ready (DRDY);

• FEED allowed at any time; and, • DRDY upon PAUSE. APPLICATOR2

Enables parameters for alternate label applicator functions:

• Completion upon 1 msec. overlap of Data Ready (DRDY) and End of Print (EOP);

• DRDY signal end inhibits FEED; and, • De-asserts DRDY upon PAUSE or FAULT.

34

BARCODE VERIFIER

Enables the GPIO Port to work with a bar code verifier.

DISABLED

Disables the option.

I-Class

Page 45

Printer Options (continued) Menu Item START OF PRINT ACTIVE HIGH

Selects the type of input signal required to initiate printing, where: Triggers printing with a high signal.

EDGE

Triggers printing with a signal edge transition.

LOW PULSE

Triggers printing with a low pulse.

HIGH PULSE

Triggers printing with a high pulse.

ACTIVE LOW

Triggers printing with a low signal.

END OF PRINT

Sets the type of output signal generated to indicate End of Print (EOP), where:

LOW PULSE

Outputs a low pulse upon completion.

HIGH PULSE

Outputs a high pulse upon completion.

ACTIVE LOW

Outputs a logic low upon completion.

ACTIVE HIGH

Outputs a logic high upon completion.

RIBBON LOW

Sets the low ribbon signal (as determined by RIBBON LOW OPTIONS; see Section 4.2.2), where:

ACTIVE LOW

Outputs a logic low when the roll reaches the setting.

ACTIVE HIGH

Outputs a logic high when the roll reaches the setting.

SLEW ENABLE

I-Class

Details

Selects the type of input signal required to initiate label slew, where:

STANDARD

Triggers slew with a low signal.

LOW PULSE

Triggers slew with a low pulse.

HIGH PULSE

Triggers slew with a high pulse.

ACTIVE LOW

Triggers slew with a low signal.

ACTIVE HIGH

Triggers slew with a high signal.

35

Page 46

Printer Options (continued) Menu Item BACKUP LABEL

DISABLED

Details Positions a presented label for printing (provided the PRESENT DISTANCE setting is greater than zero), where: Disables backup positioning.

ACTIVE LOW

Positions the label when a logic low is received.

ACTIVE HIGH

Positions the label when a logic high is received.

ERR ON PAUSE (APP2)

Sets the output when a service required fault occurs, where:

ENABLED

Enables the output signal.

DISABLED

Disables the output signal.

4.2.5 System Settings The System Settings menu contains operating, control, and formatting functions: Menu Item CONFIGURATION FILE

Details Controls the creation, storage, and recall of printer configuration files (see Appendix D), where:

RESTORE AS CURRENT

Lists the files available, and then after selection reconfigures the printer according to that file.

SAVE SETTING AS

Saves the effective configuration of the printer to a named file of up to nineteen characters.

DELETE FILE

Lists the files available, and then after selection, removes that file from memory. Note:

FACTORY SETTING FILE

NONE

36

A currently activated file cannot be deleted.

Lists the files available and then after selection that file will be restored whenever a Level One reset is performed; see Section 5.3.2. Is the currently selected file.

I-Class

Page 47

System Settings (continued) Menu Item INTERNAL MODULE D 1024 K (XXX - XXXX) DEFAULT MODULE D SCALEABLE FONT CACHE 0312 K (100 - 5120) SINGLE BYTE SYMBOLS

PC–850 MULTILINGUAL DOUBLE BYTE SYMBOLS

UNICODE

Details Allocates a number of 1KB memory blocks for internal Memory Module D; where: Is the memory allocation; see Appendix A for the memory ranges, types, and availability. Designates the memory module for storage when no other location is specified; where: Is the module; see Appendix A for availability. Configures the number of 1KB memory blocks for the scaleable font engine; where: Is the memory allocation; see Appendix A for availability. Selects from the 66 available code pages used for single byte fonts (unless otherwise specified in DPL); where: Is the selected code page; for details see the Class Series 2 Programmer’s Manual. Selects the code page (see the Class Series 2 Programmer’s Manual) used for the ILPC option (unless otherwise specified), where: Selects Unicode (including Korean).

GB

Selects Government Bureau Industry Standard, Chinese (PRC).

BIG 5

Selects Taiwan encoded.

JIS

Selects Japanese Industry Standard.

SHIFT JIS

Selects Shift Japanese Industry Standard.

EUC

Selects Extended UNIX Code.

TIME AND DATE SET HOUR 06:30AM 01JAN2000

I-Class

Allows the user to set the time and date; where: Enters the information for the time and date fields. Note:

Time and date retention (after power removal) requires the Real Time Clock function; see GPI/O Multi-Expansion CCA, Section 1.1.2.

37

Page 48

System Settings (continued) Menu Item MEDIA COUNTERS

Details Provides a recorded count of inches printed and time; where:

ABSOLUTE COUNTER

Shows the total number of inches printed and the set date. (Non-resettable)

RESETTABLE COUNTER

Shows the number of inches printed and the last reset date.

RESET COUNTER

Returns the RESETTABLE COUNTER to zero.

PRINT CONFIGURATION

Prints a Configuration Label of current database information where items denoted with the section (§) and bullet (•) symbol indicate changes not yet saved.

CONFIGURATION LEVEL

Displays the hardware and software feature level of the printer, where:

PRINTER KEY

Identifies the unique key number of the printer, in the form vvvv-wwxx-yyyyyy-zzz Where: vvvv

–

Represents the printer model number.

wwxx

–

Represents the hardware and software levels, where: ww – Represents the main logic card type: PA = CCA 51-2178-XX; or TB = CCA 51-2301-XX xx – Represents the software feature level: 10 = Standard DPL 11 = 4208 20 = Internal CG Times Font yyyyyy zzz

38

– Is a manufacturing date code. – Is a unique time stamp.

APPLICATION VERSION

Displays the level, version number, and date of the application firmware.

BOOT LOADER

Displays the Boot Loader version level and date.

UPGRADE PRINTER CODE 000000

Upgrades the printer to the corresponding feature level. (Authorization required.)

I-Class

Page 49

System Settings (continued) Menu Item

Details

UNLOCK FEATURE 000000

Unlocks a corresponding feature with the entry of the correct code.

SET FACTORY DEFAULTS

Returns the printer settings to the factory-programmed values or the Factory Setting File values, where:

SET FACTORY DEFAULT? CANCEL KEY = YES

Overwrites the current configuration and restores the default configuration ( ), or if selected the Factory Setting File. Otherwise, press the ESC Key to keep the current configuration. Note:

FORMAT ATTRIBUTES

A reset will occur and, if no Factory Setting File is used, all settings returned except CUSTOM ADJUSTMENTS and calibrations.

Defines the way overlapping text, bar codes, and graphics are printed, where:

XOR

Does not print intersecting areas, for example:

OPAQUE

Overwrites intersecting areas with those last formatted, for example:

TRANSPARENT

Prints intersecting areas, for example:

LABEL ROTATION DISABLED ENABLED IMAGING MODE ♦ MULTIPLE LABEL

Allows the label format to be rotated 180 degrees, where: Prints formats without rotation. Prints flipped formats. Determines the process used to format labels, where: Formats multiple images, as memory permits, to achieve the fastest throughput. Note:

SINGLE LABEL PAUSE MODE DISABLED ENABLED

I-Class

Time stamps will indicate the moment of imaging rather than printing.

Formats an image only after a previous format has been printed to achieve the most accurate time stamps. Allows controlled interactive printing, where: Prints labels without pausing. Requires the user to press the PAUSE Key to print each label.

39

Page 50

System Settings (continued) Menu Item PEEL MODE DISABLED ENABLED SECURITY ♦ SELECT SECURITY

Details Allows the SOP signal to initiate (via GPIO option) the feeding of the labels, where: Feeds regardless of SOP. Feeds only when SOP is received. Allows menu password protection, where: Enables or disables the security feature, where: Note:

DISABLED

The default password must be changed to activate.

Allows entry.

SECURE MENU

Sets a password requirement for menu entry.

MENU AND TEST

Sets a password requirement for menu and test entries.

MODIFY PASSWORD MODIFY PASSWORD? CANCEL KEY = YES

Modifies the four-digit password required when security is enabled, where: Enters the password (after confirmation); otherwise, press the ESC Key to keep the current password. Note:

UNITS OF MEASURE IMPERIAL METRIC

The default password is 0000.

Sets the measurement standard for the printer, where: Uses inches. Uses millimeters and centimeters.

INPUT MODE

Defines the type of processing that occurs when data is received, where:

DPL

Processes data for standard DPL printing; see the Class Series 2 Programmer’s Manual.

LINE

Processes data for template (Line Mode) printing; see the Class Series 2 Programmer’s Manual.

40