Prompts and Condition Messages (continued) Displayed Message
Description
Action
SYSTEM INITIALIZING!!
The power switch has been turned ON or a reset has occurred.
No action is required. Wait briefly while the process completes.
SYSTEM RESET IN PROGRESS!
A reset has occurred.
No action is required. Wait briefly while the process completes.
UNCALIBRATED
The Media Sensor is not calibrated.
Perform calibration; see Section 5.2.
WAITING FOR DATA
The SOP signal has been received, but the printer awaits label data.
Send data from the host.
WAITING FOR SIGNAL
The printer awaits a SOP signal.
Send the SOP signal from the applicator to the GPIO port.
XXXX OF XXXX PRINTING!
A print job is in process, as indicated by the batch total and remaining label count.
No action is required.
5.2 Calibration Calibration ensures label detection. Perform calibration when the UNCALIBRATED is displayed. Two different methods, Standard and Advanced Entry, are available to calibrate the printer.
5.2.1 Standard Calibration Standard Calibration, appropriate for most media types, is a method that allows visual access to the media sensor for positioning. Displayed sensor readings can also be used to indicate the best position over the media – helpful when using small, position-critical TOF notches or marks.
I-Class
61
Page 72
Three samples are required:
•
Empty: Nothing in the sensor.
•
Gap (or Mark): The media liner, notch, or reflective mark in the sensor.
•
Paper: The label (and liner, if any) in the sensor.
With the correct SENSOR TYPE selected (see Section 4.2.2), perform a Standard Calibration as follows:
Step 1
2
Action
Displayed Message
Comment
Turn ON the printer.
UNCALIBRATED
Wait briefly, about six seconds, for the printer to initialize.
Key, and Press the then raise the printhead assembly.
MENU MODE MEDIA SETTINGS
You are in MENU MODE.
MEDIA SETTINGS MEDIA TYPE
You are in MEDIA SETTINGS.
Key.
3
Press the
4
Key then Press the scroll to SENSOR CALIBRATION.
5
Press the
6
62
Key.
Key, and Press the then press any key.
MEDIA SETTINGS SENSOR CALIBRATION
Key to Press the cancel this procedure.
SENSOR CALIBRATION PERFORM CALIBRATION
You are beginning the procedure.
REMOVE LABEL STOCK PRESS ANY KEY <yyy>
No media should be in the sensor. This sets the Empty value, where “yyy” is the current sensor reading.
I-Class
Page 73
Standard Calibration (continued) Step
Action
Displayed Message
Comment
Proceed according to your media: • Die-cut – remove a label from the backing material then place the backing in the sensor. Adjust the Sensor Eye Mark over the center of the backing.
• Notched – load media in
7 the printer then adjust the Sensor Eye Mark over the center of the notch.
• Reflective – load media in the printer (black mark facedown) then adjust the Sensor Eye Mark over the center of the black mark.
See Section 3.3 for sensor positioning details.
SCAN BACKING PRESS ANY KEY <yyy>! ! ! Or, for reflective media: ! ! SCAN MARK PRESS ANY KEY <yyy>!
This sets the backing, gap, or mark value where “yyy” is the current sensor reading.
Note: Never position the sensor over a perforation when sampling.
• Continuous – go to Step
8.
Press any key to continue. Note: Do not move the Media Sensor after it has been positioned.
Step
8
I-Class
Action
Position the media (and backing, if any) under the sensor then press any key to continue.
Displayed Message
Comment This sets the paper value, where “yyy” is the current sensor reading.
SCAN PAPER PRESS ANY KEY <yyy>
!
Note: If using preprinted media, ensure the label area under the Sensor Eye Mark is free of text, graphics, or borders.
63
Page 74
Standard Calibration (continued) Step
9
Action
Observe the LCD.
Displayed Message GAP MODE CALIBRATION COMPLETE ! Or, for reflective media: ! REFLECTIVE MODE CALIBRATION COMPLETE! ! Or, for continuous media: !! CONTINUOUS MODE CALIBRATION COMPLETE
Comment
The calibration was successful if CALIBRATION COMPLETE appears. (If, however, another message was displayed see Note 1, below.)
!
The printer is ready. If this calibration was unsuccessful, go to Section 5.2.2.
Press the Key three times to exit the menu.
Notes:
10
Users of circular or irregularly shaped die-cut media see Note 2 before proceeding. If using gap, notch or reflective media, press and hold the FEED Key. Allow at least one label to advance from the printer before releasing the key.
64
READY !
(1) WARNING LOW BACKING is a normal message when calibrating notched media or media with transparent backing; see Section 6.1.2 for other possible messages. (2) If using circular or irregularly shaped die-cut labels, reposition the Sensor Eye Mark over the widest part of a label.
I-Class
Page 75
5.2.2 Advanced Entry Calibration Advanced Entry is the alternate calibration method for special-case media types. In the procedure, sensor readings for the label and TOF values are taken using different sampling algorithms. From this compiled list of values the best algorithm is selected and then used to generate new readings for manual entry into memory. Note: Use this method only when Standard Calibration has proven unsuccessful. With the correct SENSOR TYPE selected (see Section 4.2.2), perform an Advanced Entry Calibration as follows: Step
1
2
Action
Displayed Message
Comment
Turn ON the printer.
UNCALIBRATED
Wait briefly, about six seconds, for the printer to initialize.
Key, and Press the then raise the printhead assembly.
MENU MODE MEDIA SETTINGS
You are in MENU MODE.
MEDIA SETTINGS MEDIA TYPE
You are in MEDIA SETTINGS.
Key.
3
Press the
4
Key then Press the scroll to SENSOR CALIBRATION.
MEDIA SETTINGS SENSOR CALIBRATION
Key to Press the cancel this procedure.
5
Press the then the
SENSOR CALIBRATION ADVANCED ENTRY
Press the Key to cancel this procedure.
6
Press the then the
ADVANCED ENTRY SENSOR GAIN
You are beginning the procedure.
I-Class
Key, and Key.
Key, and Key.
65
Page 76
Advanced Entry Calibration (continued) Step
Action
Press the 7
Displayed Message
Key.
Place the label under the Sensor Eye Mark, and then lower the printhead assembly.
Use the Key to scroll to the 00 GAIN setting and Key. then press the 8
Record the sensor reading as a Label Value in a table similar to the one shown below.
GAIN TRAN *00
<yyy> <0 - 31>
Comment See Section 3.3 for sensor positioning details.
! ! If using preprinted Or, for reflective media: media, ensure the label ! GAIN REFL <yyy> area under the Sensor Eye Mark is free of text, *00 <0 - 31>! graphics, or borders.
GAIN TRAN *00
<yyy> <0 - 31>
! ! Or, for reflective media:
Selection is denoted by an asterisk (*). The sensor reading equals the “yyy” value.
Note: Never position the sensor over a <yyy> perforation when <0 - 31>! sampling.
GAIN REFL *00
Sampling Table Gain Number
Label Value
00 01 02 … 31
255
Step
Action
9
Key to Press the increment the Gain Number Key then press the and record the resulting Label Value. Repeat this step for each of the remaining Gain Numbers (01-31).
66
TOF Value
Difference Value
Displayed Message GAIN TRAN *31
Comment
<yyy> <0 - 31>
! ! Or, for reflective media: GAIN REFL *31
<yyy> <0 - 31>!
I-Class
Page 77
Advanced Entry Calibration (continued) Step
Action
Displayed Message
Comment
Proceed according to your media type: • Die-cut – remove a label from the backing material then place the backing into the sensor. Adjust the Sensor Eye Mark over the center of the backing.
• Notched – adjust the
10
Sensor Eye Mark over the center of the notch.
• Reflective – adjust the
Sensor Eye Mark over the center of the facedown black mark.
GAIN TRAN *00
<yyy> <0 - 31>
! ! Or, for reflective media: GAIN REFL *00
Note: Never position the sensor over a perforation when sampling.
<yyy> <0 - 31>!
Key to scroll Use the to the 00 GAIN setting and Key. then press the Record the sensor reading as a TOF Value.
Note: Do NOT move the Media Sensor after it has been positioned.
Sampling Table Gain Number 00 01 02 … 31
I-Class
Label Value 255 251 241 … 112
TOF Value 254
Difference Value
67
Page 78
Advanced Entry Calibration (continued) Step
Action
GAIN TRAN *31
11
Press the Key to increment the Gain Number Key then press the and record the resulting TOF Value. Repeat this step for each of the remaining Gain Numbers (01-31).
GAIN REFL *31
<yyy> <0 - 31>!
GAIN TRAN *31
<yyy> For example in the table <0 - 31>! below, Gain Number 08 is
12
Displayed Message
From the collected data, where both the values are above 20, subtract the Label Value from the corresponding TOF Value to find the Difference Value. Note the Gain Number of the largest Difference Value.
Comment
<yyy> <0 - 31>
! ! Or, for reflective media:
! ! Or, for reflective media: GAIN REFL *31
<yyy> <0 - 31>!
chosen because it has the highest Difference Value (146) where both the Label and the TOF Values are above 20.
Sampling Table
Step
13
68
Gain Number
Label Value
TOF Value
Difference Value
00 01 02 03 04 05 06 07 08 09 10 … 31
255 251 241 231 219 212 200 189 178 167 156 … 116
254 240 213 182 150 119 88 58 32 19 17 … 14
1 11 28 49 69 93 112 131 146 N/A N/A … N/A
Action
Using the Key, scroll to the Gain Number determined in Step 12, and then press the Key.
Displayed Message GAIN TRAN *08
Comment
<yyy> <0 - 31>
! ! Or, for reflective media: GAIN REFL *08
<yyy> <0 - 31>!
I-Class
Page 79
Advanced Entry Calibration (continued) Step
Action a) Place the media in the sensor. Record the reading and label it “P” (paper).
14 b) Place the backing, notch, or mark in the sensor. Record the reading and label it “G” or “M” (Gap or Mark). c) Remove media. Record the reading and label it “E” (Empty).
15
Press the then press the
Key, and Key.
Displayed Message
GAIN TRAN *08
Comment
<yyy> <0 - 31>
! ! Or, for reflective media: GAIN REFL *08
The samplings using the selected Gain Number are taken.
<yyy> <0 - 31>!
ADVANCED ENTRY SENSOR LEVELS!
The sensor readings must be entered into the printer.
PAPER SENSOR LEVEL P*198 G*084 E*014
Press the
16
Key.
Using the Key or the Key, set the Paper Sensor Level to the value determined in the previous step. Key to Press the select the entry and advance the menu. Repeat for the Gap Sensor Level (or Mark Sensor Level) and the Empty Sensor Level entries.
GAP SENSOR LEVEL P*198 G*084 E*014
EMPTY SENSOR LEVEL P*198 G*084 E*014
Selection is denoted by an asterisk (*).
Or, for reflective media:
The displayed message will change and the selection will flash to indicate the next entry.
PAPER SENSOR LEVEL! P*015 M*181 E*213 !
MARK SENSOR LEVEL! P*015 M*181 E*213 !
EMPTY SENSOR LEVEL! P*015 M*181 E*213!
I-Class
69
Page 80
Advanced Entry Calibration (continued) Step
Action
Displayed Message
Comment
17
After all entries have been Key made, press the to back out of the menu and Key then press the to save the settings and return to the Ready Mode.
SAVE CHANGES? ENTER KEY = YES
From READY, press the FEED Key to advance to the next label TOF.
!
Note: If the Advanced Entry Calibration fails, enter MEDIA SETTINGS / CALIBRATION / ADVANCED ENTRY / SENSOR GAIN and lower the selected Gain Number by one. Select the new Gain Number then save the changes and exit the menu. Retest your media. If unsuccessful, repeat the procedure until a usable gain is obtained.
5.3 Reset Methods There are three reset methods, each with a different affectivity. Proceed according to the desired result:
5.3.1 Soft Reset To clear any temporary host settings, press and hold the CANCEL Key for approximately four seconds.
5.3.2 Level One Reset To return the factory default settings or (if saved) a Factory Setting File, turn OFF the printer. Press and hold the PAUSE and CANCEL Keys while turning ON the printer and until the SYSTEM RESET message flashes. Note:
The same as selecting SET FACTORY DEFAULTS; see Section 4.2.5.
5.3.3 Level Two Reset To return the firmware default settings and clear all parameters, turn OFF the printer. Press and hold the PAUSE, FEED, and CANCEL Keys while turning ON the printer and until the SYSTEM RESET message flashes. Note:
70
Calibration is required; see Section 5.2.
I-Class