Page 43
Scanning Features
Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 4 for some examples of how to set this feature. Table 4. Scanning Active Time Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Pad leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SCANNING ACTIVE TIME SETTING
5 6
Scan Three Characters From
Appendix E, Keypad
1 Second 001
‘0’, ‘0’ and ‘1’
90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.) 090
180
255
‘0’, ‘9’ and ‘0’
‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
33
Page 44
General Features
Scanning Active Time, cont.
ENTER/EXIT PROGRAMMING MODE
Select Scanning Active Time Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
34
005 = Scanning is active for 5 Seconds
QuickScan® QD2100
Page 45
Flash On Time
Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH ON TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 5 for some examples of how to set this feature. Table 5. Flash On Time Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Divide by 100 (and pad with leading zeroes to yield two digits)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
5 6
Scan Two Characters From
Appendix E, Keypad
500ms
1,000ms (1 sec.) 5200ms (5.2 sec.)
9,900ms (9.9 sec.)
05
10
52
99
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
35
Page 46
General Features
Flash On Time, cont.
ENTER/EXIT PROGRAMMING MODE
Select Flash ON Time Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
36
10 = Flash is ON for 1 Second
QuickScan® QD2100
Page 47
Flash Off Time
Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH OFF TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 6 for some examples of how to set this feature. Table 6. Flash Off Time Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Divide by 100 (and pad with leading zeroes to yield two digits)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
5 6
Scan Two Characters From
Appendix E, Keypad
500ms
1,000ms (1 sec.) 5200ms (5.2 sec.)
9,900ms (9.9 sec.)
05
10
52
99
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
37
Page 48
General Features
Flash Off Time, cont.
ENTER/EXIT PROGRAMMING MODE
Select Flash OFF Time Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
38
06 = Flash is OFF for 600ms
QuickScan® QD2100
Page 49
Stand Mode Sensitivity
Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.
ENTER/EXIT PROGRAMMING MODE
Stand Mode Sensitivity = Low
DEFAULT Stand Mode Sensitivity = Medium
Stand Mode Sensitivity = High
Product Reference Guide
39
Page 50
General Features
Green Spot Duration Specifies the duration of the good read pointer beam after a good read.
ENTER/EXIT PROGRAMMING MODE
Green Spot Duration = Disable (Green Spot is Off)
DEFAULT Green Spot Duration = Short (300 msec)
Green Spot Duration = Medium (500 msec)
Green Spot Duration = Long (800 msec)
40