Page 43

Scanning Features

Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 4 for some examples of how to set this feature. Table 4. Scanning Active Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Pad leading zero(es)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT SCANNING ACTIVE TIME SETTING

5 6

Scan Three Characters From

Appendix E, Keypad

1 Second 001

‘0’, ‘0’ and ‘1’

90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.) 090

180

255

‘0’, ‘9’ and ‘0’

‘1’, ‘8’ and ‘0’

‘2’, ‘5’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

33

Page 44

General Features

Scanning Active Time, cont.

ENTER/EXIT PROGRAMMING MODE

Select Scanning Active Time Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

34

005 = Scanning is active for 5 Seconds

QuickScan® QD2100

Page 45

Flash On Time

Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH ON TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 5 for some examples of how to set this feature. Table 5. Flash On Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Divide by 100 (and pad with leading zeroes to yield two digits)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT FLASH OFF TIME SETTING

5 6

Scan Two Characters From

Appendix E, Keypad

500ms

1,000ms (1 sec.) 5200ms (5.2 sec.)

9,900ms (9.9 sec.)

05

10

52

99

‘0’ and ‘5’

‘1’ and ‘0’

‘5’ and ‘2’

‘9’ and ‘9’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

35

Page 46

General Features

Flash On Time, cont.

ENTER/EXIT PROGRAMMING MODE

Select Flash ON Time Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

36

10 = Flash is ON for 1 Second

QuickScan® QD2100

Page 47

Flash Off Time

Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH OFF TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 6 for some examples of how to set this feature. Table 6. Flash Off Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Divide by 100 (and pad with leading zeroes to yield two digits)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT FLASH OFF TIME SETTING

5 6

Scan Two Characters From

Appendix E, Keypad

500ms

1,000ms (1 sec.) 5200ms (5.2 sec.)

9,900ms (9.9 sec.)

05

10

52

99

‘0’ and ‘5’

‘1’ and ‘0’

‘5’ and ‘2’

‘9’ and ‘9’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

37

Page 48

General Features

Flash Off Time, cont.

ENTER/EXIT PROGRAMMING MODE

Select Flash OFF Time Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

38

06 = Flash is OFF for 600ms

QuickScan® QD2100

Page 49

Stand Mode Sensitivity

Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.

ENTER/EXIT PROGRAMMING MODE

Stand Mode Sensitivity = Low

DEFAULT Stand Mode Sensitivity = Medium

Stand Mode Sensitivity = High

Product Reference Guide

39

Page 50

General Features

Green Spot Duration Specifies the duration of the good read pointer beam after a good read.

ENTER/EXIT PROGRAMMING MODE

Green Spot Duration = Disable (Green Spot is Off)

DEFAULT Green Spot Duration = Short (300 msec)

Green Spot Duration = Medium (500 msec)

Green Spot Duration = Long (800 msec)

40

QuickScan® QD2100