Page 51

Chapter 5 RS-232 ONLY Interface Introduction Use the programming barcodes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 6, RS-232/ USB-Com Interfaces.

RS-232 Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.

ENTER/EXIT PROGRAMMING MODE

Baud Rate = 1200

Baud Rate = 2400

Baud Rate = 4800

Product Reference Guide

41

Page 52

RS-232 ONLY Interface

Baud Rate, continued

ENTER/EXIT PROGRAMMING MODE

DEFAULT Baud Rate = 9600

Baud Rate = 19,200

Baud Rate = 38,400

Baud Rate = 57,600

Baud Rate = 115,200

42

QuickScan® QD2100

Page 53

Data Bits

Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.

ENTER/EXIT PROGRAMMING MODE

7 Data Bits

DEFAULT 8 Data Bits

Product Reference Guide

43

Page 54

RS-232 ONLY Interface

Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

ENTER/EXIT PROGRAMMING MODE

DEFAULT 1 Stop Bit

2 Stop Bits

44

QuickScan® QD2100

Page 55

Parity

Parity This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. •

Select None when no parity bit is required.

•

Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

•

Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Parity = None

Parity = Even

Parity = Odd

Product Reference Guide

45

Page 56

RS-232 ONLY Interface

Handshaking Control The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking Control includes the following options: •

RTS, RTS is asserted during transmissions. CTS is ignored.

•

RTS/CTS, RTS is asserted during transmissions. CTS gates transmissions.

•

RTS/XON/XOFF, RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions.

•

RTS On/CTS, RTS is always asserted. CTS gates transmissions.

•

RTS/CTS Scan Control, RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Handshaking Control = RTS

Handshaking Control = RTS/CTS

Handshaking Control = RTS/XON/XOFF

Handshaking Control = RTS On/CTS

Handshaking Control = RTS/CTS Scan Control

46