Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 48

QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: General Features, pages 35 to 42

Pages 35 to 42 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic QD2110 and Datalogic QD2130

Page 35

LED and Beeper Indicators

Good Read Beep Length, continued

ENTER/EXIT PROGRAMMING MODE

DEFAULT Good Read Beep Length = 80 msec

Good Read Beep Length = 100 msec

Good Read Beep Length = 120 msec

Good Read Beep Length = 140 msec

Good Read Beep Length = 160 msec

Good Read Beep Length = 180 msec

Good Read Beep Length = 200 msec

Product Reference Guide

25

Page 36

General Features

Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Volume = Beeper Off

Good Read Beep Volume = Low

Good Read Beep Volume = Medium

DEFAULT Good Read Beep Volume = High

26

QuickScan® QD2100

Page 37

LED and Beeper Indicators

Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 3 for some examples of how to set this feature. Table 3. Good Read LED Duration Setting Examples STEP

ACTION

EXAMPLES Good Read LED stays on until next trigger pull (00)

200ms

1500ms (1.5 sec.)

2500ms (2.5 sec.)

000

002

015

025

‘0’, ‘0’ and ‘2’

‘0’, ‘1’ and ‘5’

‘0’, ‘2’ and ‘5’

1

Desired Setting

2

Divide by 10 (and pad with leading zeroes)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5 6

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

27

Page 38

General Features

Good Read LED Duration, cont.

ENTER/EXIT PROGRAMMING MODE

Select Good Read LED Duration Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

020 = Good Read LED stays on for 2 seconds.

Indicators are dimmed during sleep. NOTE

28

QuickScan® QD2100

Page 39

Scanning Features

Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single, When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released

This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum Scanning Active Time has elapsed. Trigger Hold Multiple, When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Trigger Pulse Multiple, When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Flashing, The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the imager reads continuously. When Flash is OFF scanning is deactivated. Always On, No trigger pull is required to read a barcode. Scanning is continually on.

If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Stand Mode, No trigger pull is required to read a barcode. Scanning is turned on au-tomatically when an item is placed in reader’s field of view. If the trigger is pulled, the reader acts as if it in single read mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Trigger Object Sense, This mode is similar to Stand Mode, except that a trigger pull is required to activate the decoder.

1. Controlled by Flash On Time.

Product Reference Guide

29

Page 40

General Features

Scan Mode, continued

ENTER/EXIT PROGRAMMING MODE

DEFAULT Scan Mode = Trigger Single

Scan Mode = Trigger Hold Multiple

Scan Mode = Trigger Pulse Multiple

Scan Mode = Flashing

Scan Mode = Always On

Scan Mode = Stand Mode

Scan Mode = Trigger Object Sense

30

QuickScan® QD2100

Page 41

Scanning Features

Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode. This timeout is only used when the Scan Mode is configured as Stand

Mode. NOTE

ENTER/EXIT PROGRAMMING MODE

DEFAULT Stand Mode Triggered Timeout = 0.5 Seconds

Stand Mode Triggered Timeout = 1.5 Seconds

Stand Mode Triggered Timeout = 2 Seconds

Stand Mode Triggered Timeout = 3 Seconds

Stand Mode Triggered Timeout = 4 Seconds

Product Reference Guide

31

Page 42

General Features

Stand Mode Triggered Timeout, continued

ENTER/EXIT PROGRAMMING MODE

Stand Mode Triggered Timeout = 6 Seconds

Stand Mode Triggered Timeout = 8 Seconds

Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull

32

QuickScan® QD2100