Page 35
LED and Beeper Indicators
Good Read Beep Length, continued
ENTER/EXIT PROGRAMMING MODE
DEFAULT Good Read Beep Length = 80 msec
Good Read Beep Length = 100 msec
Good Read Beep Length = 120 msec
Good Read Beep Length = 140 msec
Good Read Beep Length = 160 msec
Good Read Beep Length = 180 msec
Good Read Beep Length = 200 msec
Product Reference Guide
25
Page 36
General Features
Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Volume = Beeper Off
Good Read Beep Volume = Low
Good Read Beep Volume = Medium
DEFAULT Good Read Beep Volume = High
26
QuickScan® QD2100
Page 37
LED and Beeper Indicators
Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 3 for some examples of how to set this feature. Table 3. Good Read LED Duration Setting Examples STEP
ACTION
EXAMPLES Good Read LED stays on until next trigger pull (00)
200ms
1500ms (1.5 sec.)
2500ms (2.5 sec.)
000
002
015
025
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘0’, ‘2’ and ‘5’
1
Desired Setting
2
Divide by 10 (and pad with leading zeroes)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5 6
Scan Three Characters From
Appendix E, Keypad
‘0’, ‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
27
Page 38
General Features
Good Read LED Duration, cont.
ENTER/EXIT PROGRAMMING MODE
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
020 = Good Read LED stays on for 2 seconds.
Indicators are dimmed during sleep. NOTE
28
QuickScan® QD2100
Page 39
Scanning Features
Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: Trigger Single, When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum Scanning Active Time has elapsed. Trigger Hold Multiple, When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Trigger Pulse Multiple, When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Flashing, The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the imager reads continuously. When Flash is OFF scanning is deactivated. Always On, No trigger pull is required to read a barcode. Scanning is continually on.
If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Stand Mode, No trigger pull is required to read a barcode. Scanning is turned on au-tomatically when an item is placed in reader’s field of view. If the trigger is pulled, the reader acts as if it in single read mode. Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode. Trigger Object Sense, This mode is similar to Stand Mode, except that a trigger pull is required to activate the decoder.
1. Controlled by Flash On Time.
Product Reference Guide
29
Page 40
General Features
Scan Mode, continued
ENTER/EXIT PROGRAMMING MODE
DEFAULT Scan Mode = Trigger Single
Scan Mode = Trigger Hold Multiple
Scan Mode = Trigger Pulse Multiple
Scan Mode = Flashing
Scan Mode = Always On
Scan Mode = Stand Mode
Scan Mode = Trigger Object Sense
30
QuickScan® QD2100
Page 41
Scanning Features
Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode. This timeout is only used when the Scan Mode is configured as Stand
Mode. NOTE
ENTER/EXIT PROGRAMMING MODE
DEFAULT Stand Mode Triggered Timeout = 0.5 Seconds
Stand Mode Triggered Timeout = 1.5 Seconds
Stand Mode Triggered Timeout = 2 Seconds
Stand Mode Triggered Timeout = 3 Seconds
Stand Mode Triggered Timeout = 4 Seconds
Product Reference Guide
31
Page 42
General Features
Stand Mode Triggered Timeout, continued
ENTER/EXIT PROGRAMMING MODE
Stand Mode Triggered Timeout = 6 Seconds
Stand Mode Triggered Timeout = 8 Seconds
Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull
32
QuickScan® QD2100