Page 27
Chapter 4 General Features Double Read Timeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label that is read.
ENTER/EXIT PROGRAMMING MODE
Double Read Timeout = 0.1 Second
Double Read Timeout = 0.2 Second
Double Read Timeout = 0.3 Second
DEFAULT Double Read Timeout = 0.4 Second
Product Reference Guide
17
Page 28
General Features
Double Read Timeout, continued
ENTER/EXIT PROGRAMMING MODE
Double Read Timeout = 0.5 Second
Double Read Timeout = 0.6 Second
Double Read Timeout = 0.7 Second
Double Read Timeout = 0.8 Second
Double Read Timeout = 0.9 Second
Double Read Timeout = 1 Second
18
QuickScan® QD2100
Page 29
Label Gone Timeout
Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING. 5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 2 for some examples of how to set this feature. Table 2. Timeout Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
50ms
150ms
1800ms (1.8 sec.)
2550ms (2.55 sec.)
2
Divide by 10 (and pad with leading zeroes)
005
015
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING ‘0’, ‘1’ and ‘5’
‘1’, ‘8’ and ‘0’
‘‘2’, ‘5’ and ‘5’
5 6
Scan Three Characters From
Appendix E, Keypad
‘0’, ‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
19
Page 30
General Features
Label Gone Timeout, cont.
ENTER/EXIT PROGRAMMING MODE
Select Label Gone Timeout Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
20
016 = Timeout of 160 ms
QuickScan® QD2100
Page 31
LED and Beeper Indicators
LED and Beeper Indicators Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power.
ENTER/EXIT PROGRAMMING MODE
Power On Alert = Disable (No Audible Indication)
DEFAULT Power On Alert = Four Beeps
Product Reference Guide
21
Page 32
General Features
Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: •
Good Read = Indicate after decode
•
Good Read = Indicate after transmit
•
Good Read = Indicate after CTS goes inactive, then active This option, which uses CTS, is only valid for RS-232 interfaces. NOTE
ENTER/EXIT PROGRAMMING MODE
DEFAULT Indicate Good Read = After Decode
Indicate Good Read = After Transmit
Indicate Good Read = After CTS Goes Inactive, Then Active
22
QuickScan® QD2100
Page 33
LED and Beeper Indicators
Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Good Read Beep Type = Mono
Good Read Beep Type = Bitonal
Product Reference Guide
23
Page 34
General Features
Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Frequency = Low
Good Read Beep Frequency = Medium
DEFAULT Good Read Beep Frequency = High
Good Read Beep Length Specifies the duration of a good read beep.
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Length = 60 msec
24
QuickScan® QD2100