QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: General Features, pages 27 to 34

Pages 27 to 34 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic QD2110 and Datalogic QD2130

Page 27

Chapter 4 General Features Double Read Timeout To prevent a double read of the same label, the Double Read Timeout sets the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the Double Read Timeout, the second read of the label will be ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label that is read.

ENTER/EXIT PROGRAMMING MODE

Double Read Timeout = 0.1 Second

Double Read Timeout = 0.2 Second

Double Read Timeout = 0.3 Second

DEFAULT Double Read Timeout = 0.4 Second

Product Reference Guide

17

Page 28

General Features

Double Read Timeout, continued

ENTER/EXIT PROGRAMMING MODE

Double Read Timeout = 0.5 Second

Double Read Timeout = 0.6 Second

Double Read Timeout = 0.7 Second

Double Read Timeout = 0.8 Second

Double Read Timeout = 0.9 Second

Double Read Timeout = 1 Second

18

QuickScan® QD2100

Page 29

Label Gone Timeout

Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING. 5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 2 for some examples of how to set this feature. Table 2. Timeout Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

1800ms (1.8 sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with leading zeroes)

005

015

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING ‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

5 6

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

19

Page 30

General Features

Label Gone Timeout, cont.

ENTER/EXIT PROGRAMMING MODE

Select Label Gone Timeout Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

20

016 = Timeout of 160 ms

QuickScan® QD2100

Page 31

LED and Beeper Indicators

LED and Beeper Indicators Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power.

ENTER/EXIT PROGRAMMING MODE

Power On Alert = Disable (No Audible Indication)

DEFAULT Power On Alert = Four Beeps

Product Reference Guide

21

Page 32

General Features

Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. Choices are: •

Good Read = Indicate after decode

•

Good Read = Indicate after transmit

•

Good Read = Indicate after CTS goes inactive, then active This option, which uses CTS, is only valid for RS-232 interfaces. NOTE

ENTER/EXIT PROGRAMMING MODE

DEFAULT Indicate Good Read = After Decode

Indicate Good Read = After Transmit

Indicate Good Read = After CTS Goes Inactive, Then Active

22

QuickScan® QD2100

Page 33

LED and Beeper Indicators

Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Good Read Beep Type = Mono

Good Read Beep Type = Bitonal

Product Reference Guide

23

Page 34

General Features

Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Frequency = Low

Good Read Beep Frequency = Medium

DEFAULT Good Read Beep Frequency = High

Good Read Beep Length Specifies the duration of a good read beep.

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Length = 60 msec

24

QuickScan® QD2100