Page 291

IATA

IATA The following options apply to the IATA symbology.

IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels.

ENTER/EXIT PROGRAMMING MODE

DEFAULT IATA = Disable

IATA = Enable

IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.

ENTER/EXIT PROGRAMMING MODE

IATA Check Character Transmission = Disable

DEFAULT IATA Check Character Transmission = Enable

Product Reference Guide

281

Page 292

Symbologies

ISBT 128 The following options apply to the ISBT 128 symbology.

ISBT 128 Concatenation Enables/disables ISBT128 concatenation of 2 labels.

ENTER/EXIT PROGRAMMING MODE

DEFAULT ISBN 128 Concatenation = Disable

ISBN 128 Concatenation = Enable

282

QuickScan® QD2100

Page 293

ISBT 128

ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic.

This option is only valid when ISBT 128 Concatenation is enabled (see page 282).

NOTE

ENTER/EXIT PROGRAMMING MODE

DEFAULT ISBT 128 Concatenation Mode = Static

ISBT 128 Concatenation Mode = Dynamic

Product Reference Guide

283

Page 294

Symbologies

ISBT 128, cont. ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.

ENTER/EXIT PROGRAMMING MODE

ISBT 128 Dynamic Concatenation Timeout = 50 msec

ISBT 128 Dynamic Concatenation Timeout = 100 msec

DEFAULT ISBT 128 Dynamic Concatenation Timeout = 200 msec

ISBT 128 Dynamic Concatenation Timeout = 500 msec

ISBT 128 Dynamic Concatenation Timeout = 750 msec

ISBT 128 Dynamic Concatenation Timeout = 1 second

284

QuickScan® QD2100

Page 295

ISBT 128

ISBT 128, cont. ISBT 128 Force Concatenation When enabled, this feature forces all ISBT 128 labels to be concatenated. This option is only valid when ISBT 128 Concatenation is enabled. (see page 282). NOTE

ENTER/EXIT PROGRAMMING MODE

DEFAULT ISBT 128 Force Concatenation = Disable

ISBT 128 Force Concatenation = Enable

ISBT 128 Advanced Concatenation Options Use the Datalogic Aladdin configuration application or Contact Customer Support to set up pairs of label types for concatenation. NOTE

Product Reference Guide

285

Page 296

Symbologies

MSI The following options apply to the MSI symbology.

MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.

ENTER/EXIT PROGRAMMING MODE

DEFAULT MSI = Disable

MSI = Enable

286

QuickScan® QD2100

Page 297

MSI

MSI, cont. MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character.

ENTER/EXIT PROGRAMMING MODE

MSI Check Character Calculation = Disable

DEFAULT MSI Check Character Calculation = Enable Mod10

MSI Check Character Calculation = Enable Mod11/10

MSI Check Character Calculation = Enable Mod10/10

Product Reference Guide

287

Page 298

Symbologies

MSI, cont. MSI Check Character Transmission Enables/disables transmission of an MSI check character.

ENTER/EXIT PROGRAMMING MODE

MSI Check Character Transmission = Disable

DEFAULT MSI Check Character Transmission = Enable

MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.

ENTER/EXIT PROGRAMMING MODE

DEFAULT MSI Length Control = Variable Length

MSI = Fixed Length

288

QuickScan® QD2100

Page 299

MSI

MSI, cont. MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT MSI LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See the table below for some examples of how to set this feature. Table 37. MSI Length 1 Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT MSI LENGTH 1 SETTING

4

Scan Two Characters From the Keypad Appendix

5

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

01 Characters

‘0’ and ‘1’

07 Characters

15 Characters

50 Characters

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

289

Page 300

Symbologies

MSI, cont. MSI Set Length 1, cont.

ENTER/EXIT PROGRAMMING MODE

Select MSI Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

290

01 = Length 1 is 1 Character

QuickScan® QD2100