The text of a manual · part 36 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 291 to 300
Pages 291 to 300 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 291
IATA
IATA The following options apply to the IATA symbology.
IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT IATA = Disable
IATA = Enable
IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
IATA Check Character Transmission = Disable
DEFAULT IATA Check Character Transmission = Enable
Product Reference Guide
281
Page 292
Symbologies
ISBT 128 The following options apply to the ISBT 128 symbology.
ISBT 128 Concatenation Enables/disables ISBT128 concatenation of 2 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT ISBN 128 Concatenation = Disable
ISBN 128 Concatenation = Enable
282
QuickScan® QD2100
Page 293
ISBT 128
ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
This option is only valid when ISBT 128 Concatenation is enabled (see page 282).
NOTE
ENTER/EXIT PROGRAMMING MODE
DEFAULT ISBT 128 Concatenation Mode = Static
ISBT 128 Concatenation Mode = Dynamic
Product Reference Guide
283
Page 294
Symbologies
ISBT 128, cont. ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
ENTER/EXIT PROGRAMMING MODE
ISBT 128 Dynamic Concatenation Timeout = 50 msec
ISBT 128 Dynamic Concatenation Timeout = 100 msec
DEFAULT ISBT 128 Dynamic Concatenation Timeout = 200 msec
ISBT 128 Dynamic Concatenation Timeout = 500 msec
ISBT 128 Dynamic Concatenation Timeout = 750 msec
ISBT 128 Dynamic Concatenation Timeout = 1 second
284
QuickScan® QD2100
Page 295
ISBT 128
ISBT 128, cont. ISBT 128 Force Concatenation When enabled, this feature forces all ISBT 128 labels to be concatenated. This option is only valid when ISBT 128 Concatenation is enabled. (see page 282). NOTE
ENTER/EXIT PROGRAMMING MODE
DEFAULT ISBT 128 Force Concatenation = Disable
ISBT 128 Force Concatenation = Enable
ISBT 128 Advanced Concatenation Options Use the Datalogic Aladdin configuration application or Contact Customer Support to set up pairs of label types for concatenation. NOTE
Product Reference Guide
285
Page 296
Symbologies
MSI The following options apply to the MSI symbology.
MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT MSI = Disable
MSI = Enable
286
QuickScan® QD2100
Page 297
MSI
MSI, cont. MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character.
ENTER/EXIT PROGRAMMING MODE
MSI Check Character Calculation = Disable
DEFAULT MSI Check Character Calculation = Enable Mod10
MSI Check Character Calculation = Enable Mod11/10
MSI Check Character Calculation = Enable Mod10/10
Product Reference Guide
287
Page 298
Symbologies
MSI, cont. MSI Check Character Transmission Enables/disables transmission of an MSI check character.
ENTER/EXIT PROGRAMMING MODE
MSI Check Character Transmission = Disable
DEFAULT MSI Check Character Transmission = Enable
MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT MSI Length Control = Variable Length
MSI = Fixed Length
288
QuickScan® QD2100
Page 299
MSI
MSI, cont. MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT MSI LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 37. MSI Length 1 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 1 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
01 Characters
‘0’ and ‘1’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
289
Page 300
Symbologies
MSI, cont. MSI Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select MSI Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
290
01 = Length 1 is 1 Character
QuickScan® QD2100