Page 281
Standard 2 of 5
Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Standard 2 of 5 Stitching = Disable
Standard 2 of 5 Stitching = Enable
Product Reference Guide
271
Page 282
Symbologies
Industrial 2 of 5 The following options apply to the Industrial 2 of 5 symbology.
Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 = Disable
Industrial 2 of 5 = Enable
Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 Check Character Calculation = Disable
Industrial 2 of 5 Check Character Calculation = Enable
272
QuickScan® QD2100
Page 283
Industrial 2 of 5
Industrial 2 of 5, cont. Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE
Industrial 2 of 5 Check Character Transmission = Disable
DEFAULT Industrial 2 of 5 Check Character Transmission = Enable
Product Reference Guide
273
Page 284
Symbologies
Industrial 2 of 5, cont. Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 Length Control = Variable Length
Industrial 2 of 5 = Fixed Length
274
QuickScan® QD2100
Page 285
Industrial 2 of 5
Industrial 2 of 5, cont. Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT INDUSTRIAL 2 of 5 LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 35. Code 39 Length 1 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
01 Character
‘0’ and ‘1’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
275
Page 286
Symbologies
Industrial 2 of 5, cont. Industrial 2 of 5 Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
276
01 = Length 1 is 1 Character
QuickScan® QD2100
Page 287
Industrial 2 of 5
Industrial 2 of 5, cont. Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and fullASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 36. Code 39 Length 2 Setting Examples STEP
ACTION
EXAMPLES 00 (Ignore This Length)
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
‘0’ and ‘0’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
277
Page 288
Symbologies
Industrial 2 of 5, cont. Industrial 2 of 5 Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select Industrial 2 of5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
278
50 = Length 2 is 50 Characters
QuickScan® QD2100
Page 289
Industrial 2 of 5
Industrial 2 of 5, cont. Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read..
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 Minimum Reads = 1
Industrial 2 of 5 Minimum Reads = 2
Industrial 2 of 5 Minimum Reads = 3
Industrial 2 of 5 Minimum Reads = 4
Product Reference Guide
279
Page 290
Symbologies
Industrial 2 of 5, cont. Industrial 2 of 5 Stitching Enables/disables fixed length stitching for Industrial 2 of 5.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 Stitching = Disable
Industrial 2 of 5 Stitching = Enable
Industrial 2 of 5 Character Correlation Enable/disables character correlation for Industrial 2 of 5.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Industrial 2 of 5 Character Correlation = Disable
Industrial 2 of 5 Character Correlation = Enable
280
QuickScan® QD2100