The text of a manual · part 37 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 301 to 310
Pages 301 to 310 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 301
MSI
MSI, cont. MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT MSI LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 38. MSI Length 2 Setting Examples STEP
ACTION
EXAMPLES 00 (Ignore This Length)
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 2 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
‘0’ and ‘0’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
291
Page 302
Symbologies
MSI, cont. MSI Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
292
50 = Length 2 is 50 Characters
QuickScan® QD2100
Page 303
MSI
MSI, cont. MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE
MSI Minimum Reads = 1
MSI Minimum Reads = 2
MSI Minimum Reads = 3
DEFAULT MSI Minimum Reads = 4
Product Reference Guide
293
Page 304
Symbologies
MSI, cont. MSI Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •
Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
•
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
•
Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
ENTER/EXIT PROGRAMMING MODE
MSI Decoding Level = Disable
MSI Decoding Level = 1
MSI Decoding Level = 2
294
QuickScan® QD2100
Page 305
MSI
MSI, cont. MSI Decoding Level, cont.
DEFAULT MSI Decoding Level = 3
MSI Decoding Level = 4
MSI Decoding Level = 5
Product Reference Guide
295
Page 306
Symbologies
Plessey The following options apply to the Plessey symbology.
Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Plessey = Disable
Plessey = Enable
296
QuickScan® QD2100
Page 307
Plessey
Plessey, cont. Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character.
ENTER/EXIT PROGRAMMING MODE
Plessey Check Character Calculation = Disable
DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification
Plessey Check Character Calculation = Enable Anker check char. verification
Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification
Product Reference Guide
297
Page 308
Symbologies
Plessey, cont. Plessey Check Character Transmission Enables/disables transmission of an MSI check character.
ENTER/EXIT PROGRAMMING MODE
Plessey Check Character Transmission = Disable
DEFAULT Plessey Check Character Transmission = Enable
PLessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Plessey Length Control = Variable Length
Plessey = Fixed Length
298
QuickScan® QD2100
Page 309
Plessey
Plessey, cont. Plessey Set Length 1 This feature specifies one of the barcode lengths for PLessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT PLESSEY LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 39. Plessey Length 1 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
01 Characters
‘0’ and ‘1’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
299
Page 310
Symbologies
Plessey, cont. Plessey Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
300
01 = Length 1 is 1 Character
QuickScan® QD2100