Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 37 of 48

QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 301 to 310

Pages 301 to 310 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic QD2110 and Datalogic QD2130

Page 301

MSI

MSI, cont. MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT MSI LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See the table below for some examples of how to set this feature. Table 38. MSI Length 2 Setting Examples STEP

ACTION

EXAMPLES 00 (Ignore This Length)

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT MSI LENGTH 2 SETTING

4

Scan Two Characters From the Keypad Appendix

5

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

‘0’ and ‘0’

07 Characters

15 Characters

50 Characters

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

291

Page 302

Symbologies

MSI, cont. MSI Set Length 2, cont.

ENTER/EXIT PROGRAMMING MODE

Select MSI Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

292

50 = Length 2 is 50 Characters

QuickScan® QD2100

Page 303

MSI

MSI, cont. MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.

ENTER/EXIT PROGRAMMING MODE

MSI Minimum Reads = 1

MSI Minimum Reads = 2

MSI Minimum Reads = 3

DEFAULT MSI Minimum Reads = 4

Product Reference Guide

293

Page 304

Symbologies

MSI, cont. MSI Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •

Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.

•

Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.

•

Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.

There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.

ENTER/EXIT PROGRAMMING MODE

MSI Decoding Level = Disable

MSI Decoding Level = 1

MSI Decoding Level = 2

294

QuickScan® QD2100

Page 305

MSI

MSI, cont. MSI Decoding Level, cont.

DEFAULT MSI Decoding Level = 3

MSI Decoding Level = 4

MSI Decoding Level = 5

Product Reference Guide

295

Page 306

Symbologies

Plessey The following options apply to the Plessey symbology.

Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Plessey = Disable

Plessey = Enable

296

QuickScan® QD2100

Page 307

Plessey

Plessey, cont. Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character.

ENTER/EXIT PROGRAMMING MODE

Plessey Check Character Calculation = Disable

DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification

Plessey Check Character Calculation = Enable Anker check char. verification

Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification

Product Reference Guide

297

Page 308

Symbologies

Plessey, cont. Plessey Check Character Transmission Enables/disables transmission of an MSI check character.

ENTER/EXIT PROGRAMMING MODE

Plessey Check Character Transmission = Disable

DEFAULT Plessey Check Character Transmission = Enable

PLessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Plessey Length Control = Variable Length

Plessey = Fixed Length

298

QuickScan® QD2100

Page 309

Plessey

Plessey, cont. Plessey Set Length 1 This feature specifies one of the barcode lengths for PLessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 0 to 50). Pad the number with leading zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT PLESSEY LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See the table below for some examples of how to set this feature. Table 39. Plessey Length 1 Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT Plessey LENGTH 1 SETTING

4

Scan Two Characters From the Keypad Appendix

5

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

01 Characters

‘0’ and ‘1’

07 Characters

15 Characters

50 Characters

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

299

Page 310

Symbologies

Plessey, cont. Plessey Set Length 1, cont.

ENTER/EXIT PROGRAMMING MODE

Select Plessey Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

300

01 = Length 1 is 1 Character

QuickScan® QD2100