Page 42

DRAGON™ D131/M131

5. Read the OM-3000 restore default code: Restore OM-3000 Default

Ì$+RX0$-qÎ 6. Read the desired Enable Network code. Enable RS485 Master

Ì$+RZ2$-ÇÎ Enable RS485 Slave

Ì$+RZ1$-~Î END of procedure. For Host Master Network Layouts (see par. 3.2), The network configuration parameters can be changed through STAR-Link™ software running on the PC. Star-Link™ software can be downloaded for free from the web site: www.datalogic.com. For OM-3000 Master Network Layouts (see par. 3.2), The network configuration parameters can be changed either through the Datalogic Aladdin™ configuration software running on the PC or by reading the barcode selections in the Network section of this manual starting on page 65. If using configuration barcodes, it is advised to completely configure the cradles before reconfiguring the Dragon™ M131 reader (see below).

NOTE

34

After completing the OM-3000 cradle configuration and connections in the network, you must reconfigure the Dragon™ M131 reader using the STAR-System™ procedure in par. 4.6.

Page 43

CONFIGURATION

4.8

INTERFACE SELECTION

Read the interface selection code for your application.

RS232 Standard

Ì$+CP0$-$Î

POS TERMINALS Nixdorf Mode A

Ì$+CM2EC0$->Î Fujitsu

Ì$+CM1$-ÈÎ ICL Mode

Ì$+CM0$-ÃÎ For POS terminal default settings refer to par. 5.15.

PEN

Ì$+CP6$-BÎ

35

Page 44

DRAGON™ D131/M131

WEDGE IBM AT or PS/2 PCs

Ì$+CP500$-aÎ IBM XT

Ì$+CP503$-vÎ PC Notebook

Ì$+CP505$-ÈÎ IBM SURE1

Ì$+CP506$-$Î IBM Terminal 3153

Ì$+CP504$-}Î IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard).

KEY TRANSMISSION MODE make-only keyboard

Ì$+CP502$-oÎ make-break keyboard

Ì$+CP501$-hÎ KEYBOARD TYPE ‹ advanced keyboard

Ì$+FK1$-ÉÎ typewriter keyboard

Ì$+FK0$-ÄÎ 36

Page 45

CONFIGURATION

WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used. You do not need to make a Keyboard Nationality selection. (default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON. IBM AT - ALT mode

Ì$+CP507$-+Î PC Notebook - ALT mode

Ì$+CP508$-2Î

WYSE TERMINALS ANSI Keyboard

Ì$+CP509$-9Î PC Keyboard

Ì$+CP510$-gÎ ASCII Keyboard

Ì$+CP511$-nÎ VT220 style Keyboard

Ì$+CP514$-ÇÎ

37

Page 46

DRAGON™ D131/M131

WEDGE (CONTINUED) DIGITAL TERMINALS VT2xx/VT3xx/VT4xx

Ì$+CP512$-uÎ APPLE APPLE ADB Bus

Ì$+CP513$-|Î

38

Page 47

CONFIGURATION

4.9

USB READER CONFIGURATION

The USB interface is available for Dragon D131, OM-30x0 and C-3000 devices and is compatible with the following Operating Systems: Windows 98 (and later) Mac OS 8.0 (and later)

IBM POS for Windows 4690 Operating System

USB Start-up As with all USB devices, upon connection, the Host performs several checks by communicating with the device. During this phase normal operations are suspended (the LED on the Dragon™ D131 reader blinks). Two basic conditions must be met before the device is ready, the correct USB driver must be loaded and sufficient power must be supplied to the reader.

First Start-Up c For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). Normally the Host supplies sufficient power to the device and the start-up phase ends correctly. (The reader's LED stops blinking and the reader emits the beep OK signal). In rare cases, if the Host does not supply sufficient power to the device, a dialog box will appear on the Host and the device will be blocked (the reader's LED continues blinking). In this case, disconnect the USB device cable at the Host (the reader's LED stops blinking), and then try a different USB port as indicated by the Operating System message. (The device emits the beep OK signal. You can now read codes).

1

Connect device to Host reader LED blinks Load drivers (if requested) reader LED off - BEEP OK

2

Select desired USB interface code (USB-KBD is default)

Load drivers (if requested)

Read test codes. Device is READY d At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USBCOM interface, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web page http://www.datalogic.com. The device is ready. Successive start-ups will automatically recognize the previously loaded drivers.

39

Page 48

DRAGON™ D131/M131

USB USB-KBD

Ì$+UA03$-:Î USB-KBD-ALT-MODE

Ì$+UA04$-@Î USB-KBD-APPLE

Ì$+UA05$-FÎ USB-COM*

Ì$+UA02$-4Î USB-IBM-Table Top

Ì$+UA00$-(Î USB-IBM-Hand Held

Ì$+UA01$-.Î *

40

When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web site http://www.datalogic.com.

Page 49

CONFIGURATION

4.10

CHANGING DEFAULT SETTINGS

Once your reader is setup, you can change the default parameters to meet your application needs. Refer to the preceding paragraphs for initial configuration in order to set the default values and select the interface for your application. In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group. The first four groups are for Standard Interface parameter configuration for all Dragon™ D131 series readers and Dragon™ M131/OM-30X0 Stand Alone configurations only: RS232 USB WEDGE PEN EMULATION NETWORK PARAMETERS are available only for OM-3000 Network configurations. The following parameter groups are common to all interface applications: DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation. POWER SAVE manages overall current consumption in the reading device. READING PARAMETERS control various operating modes and indicator status functioning. DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions. CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host. It cannot be used with Pen Emulation connections. RADIO PARAMETERS (M131 series only) allow configuration of radio control parameters. DISPLAY PARAMETERS (some M131 series models only) allow configuration of reader display parameters.

41

Page 50

RS232 PARAMETERS All Dragon™ D131 Series readers + Dragon™ M131/OM-30X0 configurations only

~ ~ ~ ~ ~ ~ ~ ~ ~ ~

BAUD RATE PARITY DATA BITS STOP BITS HANDSHAKING ACK/NACK PROTOCOL FIFO INTER-CHARACTER DELAY RX TIMEOUT SERIAL TRIGGER LOCK

~ ~ ~ ~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹

3.

42

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 51

Enter Configuration

Ì$+;Î

Exit and Save Configuration

RS232

Ì$-?Î

BAUD RATE 300 baud

ÌCD1XÎ 600 baud

ÌCD2[Î 1200 baud

ÌCD3^Î 2400 baud

ÌCD4aÎ 4800 baud

ÌCD5dÎ ‹ 9600 baud

ÌCD6gÎ 19200 baud

ÌCD7jÎ 38400 baud

ÌCD8mÎ PARITY ‹ none

ÌCC0SÎ even parity

ÌCC1VÎ odd parity

ÌCC2YÎ 43