Page 52
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
DATA BITS 7 bits
ÌCA0OÎ ‹ 8 bits
ÌCA1RÎ 9 bits
ÌCA2UÎ STOP BITS ‹ 1 stop bit
ÌCB0QÎ 2 stop bits
ÌCB1TÎ HANDSHAKING ‹ disable
ÌCE0WÎ hardware (RTS/CTS)
ÌCE1ZÎ software (XON/XOFF)
ÌCE2]Î RTS always ON
ÌCE3`Î See par. 5.1.1 for details.
44
Page 53
Enter Configuration
Exit and Save Configuration
Ì$+;Î
RS232
Ì$-?Î
ACK/NACK PROTOCOL ‹ disable
ÌER0sÎ enable
ÌER1vÎ See par. 5.1.2 for details, particularly on implementing this parameter with Dragon™ M131.
FIFO disable
ÌEC0UÎ ‹ enable
ÌEC1XÎ See par. 5.1.3 for details.
INTER-CHARACTER DELAY delay between characters transmitted to Host
ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds ‹ delay disabled
45
Page 54
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
RX TIMEOUT timeout control in reception from Host
ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds ‹ rx timeout 5 seconds See par. 5.1.4 for details.
SERIAL TRIGGER LOCK ‹ disabled
ÌCR0qÎ enable and select characters
ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − −
46
First Character enables device trigger Second Character inhibits device trigger until the first character is received again.
Page 55
USB PARAMETERS USB-COM
~
~
Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock
USB-KBD
~
~
Keyboard nationality, FIFO, Inter-character delay, Inter-code delay, USB keyboard speed
USB-IBM
~
~
No parameter selection required.
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
47
Page 56
Enter Configuration
Ì$+;Î
Exit and Save Configuration
USB-COM
Ì$-?Î
HANDSHAKING ‹ disable
ÌCE0WÎ hardware (RTS/CTS)
ÌCE1ZÎ software (XON/XOFF)
ÌCE2]Î RTS always ON
ÌCE3`Î See par. 5.1.1 for details.
ACK/NACK PROTOCOL ‹ disable
ÌER0sÎ enable
ÌER1vÎ See par. 5.1.2 for details, particularly on implementing this parameter with Dragon™ M131.
FIFO disable
ÌEC0UÎ ‹ enable
ÌEC1XÎ See par. 5.1.3 for details.
48
Page 57
Enter Configuration
Ì$+;Î
Exit and Save Configuration
USB-COM
Ì$-?Î
INTER-CHARACTER DELAY delay between characters transmitted to Host
ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds ‹ delay disabled
RX TIMEOUT timeout control in reception from Host
ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds ‹ rx timeout 5 seconds See par. 5.1.4 for details.
SERIAL TRIGGER LOCK ‹ disabled
ÌCR0qÎ enable and select characters
ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − −
First Character enables device trigger Second Character inhibits device trigger until the first character is received again.
49
Page 58
Enter Configuration
Ì$+;Î
Exit and Save Configuration
USB-KBD
Ì$-?Î
KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default. Belgian
ÌFJ7yÎ English
ÌFJ4pÎ French
ÌFJ2jÎ German
ÌFJ3mÎ Italian
ÌFJ1gÎ Spanish
ÌFJ6vÎ Swedish
ÌFJ5sÎ ‹ USA
ÌFJ0dÎ
50
Page 59
Enter Configuration
Ì$+;Î
Exit and Save Configuration
USB-KBD
Ì$-?Î
The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs. Japanese
ÌFJ8|Î Russian (Latin)
ÌFJ9ÃÎ Russian (Cyrillic)
ÌFJA0Î Hungarian
ÌFJB3Î Slovenian, Croatian, Serbian (Latin)
ÌFJC6Î Romanian
ÌFJD9Î Czech Republic
ÌFJE<Î FIFO disable
ÌEC0UÎ ‹ enable
ÌEC1XÎ See par. 5.1.3 for details.
51
Page 60
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
USB-KBD
INTER-CHARACTER DELAY delay between characters transmitted to Host
ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds ‹ delay disabled
INTER-CODE DELAY delay between codes transmitted to Host
ÌFG.Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds ‹ delay disabled
USB KEYBOARD SPEED ‹ Normal
ÌUT10cÎ Fast
ÌUT01dÎ
52
Page 61
WEDGE PARAMETERS All Dragon™ D131 Series readers + Dragon™ M131/OM-30X0 configurations only
~ ~ ~ ~ ~ ~ ~ ~
KEYBOARD NATIONALITY CAPS LOCK CAPS LOCK AUTO-RECOGNITION NUM LOCK INTER-CHARACTER DELAY INTER-CODE DELAY KEYBOARD SETTING WEDGE CONTROL CHARACTER EMULATION
~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
53