Page 32

DRAGON™ D131/M131

4 CONFIGURATION 4.1 4.1.1

CONFIGURATION METHODS Reading Configuration Barcodes

This manual can be used for complete setup and configuration of your reader by following the setup procedures in this chapter (see par. 4.2 for an overview). If you wish to change the default settings, this manual provides complete configuration of your reader in an easy way. To configure your reader:

1) Open the folded page in Appendix C with the hex-numeric table and keep it open during the device configuration.

2) Read the Enter Configuration code ONCE, available at the top of each page of configuration.

3) Modify the desired parameters in one or more sections following the procedures given for each group.

4) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 5.

4.1.2

Using Datalogic Aladdin™

Datalogic Aladdin™ is a multi-platform utility program providing a quick and userfriendly configuration method via the RS232/USB-COM interface. It also allows upgrading the software of the connected device (see the Datalogic Aladdin™ Help On-Line for more details).

4.1.3

Copy Command

A previously configured device (Master), can be used to send its configuration directly to other devices of the same type (Slaves). The particular procedure for each device is given in par. 5.14.

24

Page 33

CONFIGURATION

4.1.4

Sending Configuration Strings from Host

An alternative configuration method is provided in Appendix A using the RS232 interface. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily.

4.2

SETUP PROCEDURES

For Dragon™ D131 Series readers, follow the setup procedures in pars. 4.3, and 4.8. For Dragon™ M131 Series readers, the setup procedures depend on two basic applications, Stand Alone or STAR-System™. Stand Alone applications allow communication with the Host by either the OM-30X0 cradle (par. 4.5), or by the STAR-Modem™ radio modem (par. 4.5.2). STAR-System™ applications allow communication with the Host through an RS485 network by the STARGATE™ RF base station or by the OM-3000 cradle (par. 4.6 and par. 4.7). Proceed as shown in the following diagram: Begin Setup by choosing the setup procedure for your Dragon™ reader as indicated below.

STAR-System™ Network Applications

OM-3000 Par. 4.6

Dragon™ Dx31 Par. 4.3 Par. 4.7

Stand Alone Applications

STAR-System™ Applications

Dragon™ Mx31/OM-30X0

Dragon™ Mx31/STAR-System™

Par. 4.4 Par. 4.7

Par. 4.5

Optional Par. 4.4.1

• STARGATE™ • OM-3000 Network • STAR-Modem™ in STAR-System™ Mode multiple guns per OM-3000

Dragon™ M/STAR-Modem™ in Stand Alone Mode Par. 4.4.2

End of Setup Your reader is now ready to read barcodes using the default settings.

25

Page 34

DRAGON™ D131/M131

4.3

1.

DRAGON™ D131 SETUP Read the restore default parameters code below. Restore Dragon™ D131 Default

Ì$+$*oÎ After reading the above code, go to par. 4.8 Interface Selection.

4.4

DRAGON™ M131/OM-30X0 POINT-TO-POINT SETUP

A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own OM-30x0 base station and where it is not necessary to set the Date and Time parameters. A special pre-printed bind-address label provided in the OM-30x0 base station package can be used to bind the Dragon™ M131 reader to the base station with the address coded on the label. The address is also written numerically on the label to be easily recognized. Valid addresses are in the range from 0000 to 1999. Make sure that all cradles used in the same area have different addresses. To rapidly configure your point-to-point application:

1.

Apply the bind-address label onto the OM-30x0 base station as indicated in the OM-30x0 Quick Reference Manual.

2.

When the OM-30X0 cradle is connected and powered, read the BindAddress label to pair the Dragon™ M131 to the OM-30X0 cradle. The green LED on the Dragon™ M131 will blink: the reader is ready to be positioned onto the cradle.

3.

Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the OM-30X0 cradle has been paired to the Dragon™ M131, and the green LED on the reader will go off. Green LED

If it ever becomes necessary to change the reader, just read the bind-address label applied to the cradle and position the new reader onto the cradle. Do not use multiple guns with this configuration method.

4.

Configure the OM-30X0 cradle, refer to the “OM-30X0 Quick Reference”.

END of procedure. YOUR READER IS NOW READY TO READ CODES.

26

Page 35

CONFIGURATION

4.5

DRAGON™ M131/OM-30X0 STAND ALONE SETUP Read the restore default parameters code below.

1.

Restore Dragon™M131 Default

Ì$+$*oÎ Follow the procedure below to set the radio address and bind Dragon™ M131 to the OM-30X0 cradle.

2.

Enter Configuration

3.

Set Date

Ì$+;Î ÌIA%Î + six digits for Day, Month and Year (DDMMYY)

4.

Set Time

ÌIB'Î + four digits for Hour and Minutes (HHMM)

27

Page 36

DRAGON™ D131/M131

5.

Set Radio Address

ÌRA0RFHÎ + four digits for the Dragon™ M131 Address (from 0000 to 1999). All readers used in the same area must have different addresses.

6.

Exit and Save Configuration

7.

Read the Bind code to pair the Dragon™ M131 to the OM-30X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded.

Ì$-?Î

To connect several readers to the same cradle see the following paragraph 4.5.1, ‘Using Multiple M Series Readers with Same Cradle'. Bind

Ì$+RN0$-IÎ The green LED on the Dragon™ M131 will blink; the reader is ready to be inserted into the cradle.

8. Firmly insert the reader into the OM-30X0 cradle within 10 seconds, a beep will be emitted, signaling that the OM-30X0 cradle has been paired to the Dragon™ M131, and the green LED on the reader will go off. green LED

28

Page 37

CONFIGURATION

9. Read the OM-30X0 restore default code: Restore OM-30X0 Default

Ì$+RX0$-qÎ Go to par. 4.8 Interface Selection.

4.5.1

Using Multiple M-Series Readers With Same Cradle

If you want to use several M-Series readers with the same OM-30X0 cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join (step 7). Join

7.

Ì$+RN1$-NÎ The green LED on the Dragon™ M131 will blink: the reader is ready to be positioned onto the cradle. Complete step 8.

END of procedure. All readers associated with the same cradle must have different addresses. CAUTION

YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

29

Page 38

DRAGON™ D131/M131

4.5.2

Dragon™ M131/STAR-Modem™ in Stand Alone Mode

To configure a Dragon™ M131 reader to communicate with STAR-Modem™ in Stand Alone Mode, follow the procedure in par. 4.5 substituting steps 6 and 7 with those below: STAR-Modem™ Address

6.

ÌRSRÎ Read the code above and the four-digit address of the STAR-Modem™.

7.

Exit and Save configuration

Ì$-?Î END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

30

Page 39

CONFIGURATION

4.6

DRAGON™ M/STAR-SYSTEM™ SETUP

The following procedure allows configuring a Dragon™ M131 reader to communicate with various STAR-System™ devices such as STARGATE™ RF base stations.

1.

Restore DRAGON™ M131 Default

2.

Enter Configuration

3.

Set Date

Ì$+$*oÎ Ì$+;Î ÌIA%Î + six digits for Day, Month and Year (DDMMYY)

4.

Set Time

ÌIB'Î + four digits for Hour and Minutes (HHMM)

5.

Set the connection according to the length of the codes to be read: Code Length ≤240 Characters

ÌRA1aÎ Code Length >240 Characters (not for systems with OM-3000 as Master)

ÌRA2dÎ

31

Page 40

DRAGON™ D131/M131 Set Radio Address

ÌRF8Î

6.

+ four digits from the Numeric Table in the range 0000-1999. All readers must have different addresses. First STAR-System™ Address

ÌRSRÎ

7.

Read the code above and the four-digit address of the First STAR-System™ device in the system. Set Last STAR-System™ Address

ÌRTTÎ

8.

Read the code above and the four-digit address of the Last STAR-System™ device in the system.

NOTE

Whenever the system is composed of a single base station, the first and last base station addresses (steps 7 and 8) must have the same value.

Exit and Save Configuration

9.

Ì$-?Î

END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.10.

32

Page 41

CONFIGURATION

4.7

OM-3000 STAR-SYSTEM™ NETWORK SETUP

When the OM-3000 cradle model is used in an RS485 network, it must be initially configured. To do this using configuration barcodes, follow the procedure below using any Dragon™ M131 reader.

1.

Set OM-3000 Address

Ì$+RF4Î + four digits for the OM-3000 Address (from 0000 to 1999). All cradles used in the network must have different addresses.

2.

Exit and Save configuration

3.

Read the Bind code to pair the Dragon™ M131 to the OM-3000 cradle for configuration.

Ì$-?Î

Bind

Ì$+RN0$-IÎ The green LED on the Dragon™ M131 will blink; the reader is ready to be inserted into the cradle.

4.

Firmly insert the reader into the OM-3000 cradle within 10 seconds, a beep will be emitted, signaling that the OM-3000 cradle has been paired to the Dragon™ M131, and the green LED on the reader will go off. green LED

33