Dragon D131/M131 Reference Manual: 3 DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS

Pages 26 to 31 of 212, from Dragon D131/M131 Reference Manual

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic MBC-3000

Page 26

DRAGON™ D131/M131

3

DRAGON™ LAYOUTS

M131

SYSTEM

AND

NETWORK

There are two basic system layouts that can be employed: Stand Alone systems (including Point-to-Point layouts) and Multidrop STAR-System™ Networks.

3.1 3.1.1

STAND ALONE LAYOUTS Point-to-Point Reader Layout Dragon™ M

BIND Host OM-30X0

3.1.2

Stand Alone Layout with Multiple Readers

Dragon™ M

JOIN Host

BIND

OM-30X0

In stand alone systems, each cradle is connected to a single Host.

18

Page 27

DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS

3.1.3

Multiple Stand Alone Layouts

Many stand alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses.

Dragon™ M

JOIN

JOIN

Dragon™ M Host

Host BIND

BIND OM-30X0

OM-30X0

Dragon™ M Host

BIND

OM-30X0

Multiple Stand Alone Systems in the Same Area

Since the cradles can communicate to multiple Dragon™ M131 readers, you might find it useful to employ one or more C-3000 battery chargers in addition to the OM-30X0 cradle, so that the battery re-charging operation can be performed for several scanners at the same time.

19

Page 28

DRAGON™ D131/M131

3.1.4

C-BOX Layout

Dragon™ M JOIN Scanner BIND

C-Box

OM-30X0

System cables to Host In this layout the OM-30X0 cradle is connected by a dedicated cable using the RS232 interface to a C-BOX connection box as part of a fixed scanner network. This allows the flexibility of a hand-held reading station integrated into a variety of fixed scanning applications so that all readers (both fixed and hand-held), in the system provide communications to the Host. The various C-BOX models provide many interface types for the Host system such as RS232, RS485, Profibus.

20

Page 29

DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS

3.2

MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS

Even though many stand alone systems can operate in the same physical area without interfering with each other, it may be desirable to bridge data from multiple base stations in a network to a single Host. Dragon™ M131 readers are compatible with STAR-System™ networks. These networks provide seamless active roaming for any RF reading device in the system.

3.2.1

Host Master Layout

C D

Internal Termination RS485 + VDC

C

RS485 Only

Internal Termination A

CAB-428 Splitter B RS232 RS485 + VDC

A. B. C. D.

Host Master with STAR-Link™ STAR-Box™ converter OM-3000 slave cradles STARGATE™ base stations Example Multidrop STAR-System™ Network with Host as Master

In this layout the Host acts as the Master using STAR-Link™ software. The Host is connected in RS232 to a STAR-Box™ converter which is connected to the first slave in the RS485 network. In this way the base stations provide communications between a single Host and all readers in the system. STARGATE™ base stations are used as slaves in this network. The Slaves at the ends of the network must be terminated (see the STARGATE™ and STAR-Box™ Installation Manuals and par. 2.8.3). See par. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system configuration specifications.

21

Page 30

DRAGON™ D131/M131

3.2.2

OM-3000 Master Layout

Internal Termination

C

D

RS485 + VDC

A

C

RS485 Only

Internal Termination

CAB-428 Splitter

B

RS485 Only

USB, orRS232, or Wedge, or Pen Emulation A. B. C. D.

Host OM-3000 Master cradle OM-3000 Slave cradles STARGATE™ base station Example Multidrop STAR-System™ Network with OM-3000 as Master

In this layout an OM-3000 cradle acts as the Master. The Host is connected to the OM-3000 Master using any one of the multi-standard interfaces (RS232, USB, WEDGE, or PEN Emulation). The Master is then connected to the slaves in the RS485 network. In this way the slave cradles provide communications between a single Host and all readers in the system. STARGATE™ base stations can also be used as slaves in this network. The devices at the ends of the network must be terminated (see par. 2.8.3). See pars. 4.6 and 4.7 or the Datalogic Aladdin™ Help On-Line for system configuration specifications.

22

Page 31

DRAGON™ M131 SYSTEM AND NETWORK LAYOUTS

3.2.3

Master OM-3000 Network Troubleshooting

Two diagnostic strings can be sent via RS232 from the Host to the Master cradle in order to have feedback about the network itself. #+LSlave Returns a list of all the Slaves recognized at boot up. Example: In a network where the Master cradle has address 0188 and one Slave cradle with address 0001, the response is:

188 1 #+Alive<xxxx> Executes a continuous Alive request to the slave xxxx in order to monitor the performance of the connection. A diagnostic message is displayed on the Host. Example: If this command is sent for slave cradle with address 0032, the response is:

/*32: OM-30X0 SOFTWARE RELEASE 1.00 20/10/2006*/ if there are no communication errors

/*32: FAIL*/ if there are communication errors. To exit from this command, reset the system by cycling power to the Master cradle.