READING PARAMETERS ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
TRIGGER TYPE TRIGGER SIGNAL TRIGGER CLICK TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION AIMING SYSTEM CRADLE BEEPER INTENSITY
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3. 84
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 93
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
TRIGGER TYPE ‹ hardware trigger
ÌBK1eÎ Restores TRIGGER MODE software trigger
ÌBK0bÎ Enables FLASH MODE always on
ÌBK3kÎ TRIGGER SIGNAL ‹ trigger active level
ÌBA0NÎ trigger active pulse
ÌBA1QÎ See par. 5.6.1 for details.
TRIGGER CLICK ‹ disable
ÌBc0+Î enable
ÌBc1.Î See par. 5.6.2 for details.
85
Page 94
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
READING PARAMETERS
TRIGGER-OFF TIMEOUT trigger-off timeout
ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically. ‹ trigger-off timeout disabled See par. 5.6.3 for details.
FLASH MODE "FLASH" ON duration
ÌBB0PÎ "FLASH" OFF duration
ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds. ‹ Flash-ON = 1 sec. Flash-OFF = 0.6 sec
READS PER CYCLE ‹ one read per cycle
ÌBC0RÎ multiple reads per cycle
ÌBC1UÎ See par. 5.6.4 for details.
86
Page 95
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
SAFETY TIME safety time
ÌBE&Î Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code. ‹ safety time = 0.5 sec See par. 5.6.5 for details.
BEEPER INTENSITY * very low intensity
ÌBG0ZÎ low intensity
ÌBG1]Î medium intensity
ÌBG2`Î ‹ high intensity
ÌBG3cÎ *
This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 7.5.
87
Page 96
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
BEEPER TONE tone 1
ÌBH0\Î ‹ tone 2
ÌBH1_Î tone 3
ÌBH2bÎ tone 4
ÌBH3eÎ BEEPER TYPE ‹ monotone
ÌBJ0`Î bitonal
ÌBJ1cÎ BEEPER LENGTH long
ÌBI0^Î ‹ short
ÌBI1aÎ
88
Page 97
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
GOOD READ SPOT DURATION disable
ÌBV0xÎ short
ÌBV1{Î ‹ medium
ÌBV2~Î long
ÌBV3ÅÎ AIMING SYSTEM ‹ disabled
ÌBj09Î enabled
ÌBj1<Î CRADLE BEEPER INTENSITY disable
ÌJI0fÎ low intensity
ÌJI1iÎ medium intensity
ÌJI2lÎ ‹ high intensity
ÌJI3oÎ 89
Page 98
DECODING PARAMETERS ~ ~ ~ ~ ~
INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™
~ ~ ~ ~ ~
Before changing these parameter values read the descriptions in par. 5.7. CAUTION
1. 2. 3.
90
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. ‹ = Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 99
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DECODING PARAMETERS
Ì$-?Î
INK SPREAD disable
ÌAX0{Î ‹ enable
ÌAX1~Î See par. 5.7.1 for details.
OVERFLOW CONTROL disable
ÌAW1|Î ‹ enable
ÌAW0yÎ See par. 5.7.2 for details.
INTERDIGIT CONTROL disable
ÌAV0wÎ ‹ enable
ÌAV1zÎ See par. 5.7.3 for details.
91
Page 100
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DECODING PARAMETERS
DECODING SAFETY ‹ one read
ÌED0WÎ (decoding safety disabled)
two reads
ÌED1ZÎ three reads
ÌED2]Î four reads
ÌED3`Î Required number of good reads before accepting code.
PUZZLE SOLVER™ ‹ disable
ÌAU0uÎ enable
ÌAU1xÎ In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it. To read codes using this technology, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly. Conditions: •
This parameter is only valid for the following codes: EAN 8 without Add-on
EAN 13 without Add-on
Code 128
Code 39
•
For Code 39, Check digit control is forced.
•
PuzzleSolver™ is not valid for ISBT 128 code.
92
UPC A without Add-on
Page 101
CODE SELECTION ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
AUTO-CONFIGURATION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI CODE 11 CODE 16K CODE 49 RSS CODES
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
93