Page 92

READING PARAMETERS ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

TRIGGER TYPE TRIGGER SIGNAL TRIGGER CLICK TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION AIMING SYSTEM CRADLE BEEPER INTENSITY

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹

3. 84

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 93

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

TRIGGER TYPE ‹ hardware trigger

ÌBK1eÎ Restores TRIGGER MODE software trigger

ÌBK0bÎ Enables FLASH MODE always on

ÌBK3kÎ TRIGGER SIGNAL ‹ trigger active level

ÌBA0NÎ trigger active pulse

ÌBA1QÎ See par. 5.6.1 for details.

TRIGGER CLICK ‹ disable

ÌBc0+Î enable

ÌBc1.Î See par. 5.6.2 for details.

85

Page 94

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

READING PARAMETERS

TRIGGER-OFF TIMEOUT trigger-off timeout

ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically. ‹ trigger-off timeout disabled See par. 5.6.3 for details.

FLASH MODE "FLASH" ON duration

ÌBB0PÎ "FLASH" OFF duration

ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds. ‹ Flash-ON = 1 sec. Flash-OFF = 0.6 sec

READS PER CYCLE ‹ one read per cycle

ÌBC0RÎ multiple reads per cycle

ÌBC1UÎ See par. 5.6.4 for details.

86

Page 95

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

SAFETY TIME safety time

ÌBE&Î Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code. ‹ safety time = 0.5 sec See par. 5.6.5 for details.

BEEPER INTENSITY * very low intensity

ÌBG0ZÎ low intensity

ÌBG1]Î medium intensity

ÌBG2`Î ‹ high intensity

ÌBG3cÎ *

This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 7.5.

87

Page 96

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

BEEPER TONE tone 1

ÌBH0\Î ‹ tone 2

ÌBH1_Î tone 3

ÌBH2bÎ tone 4

ÌBH3eÎ BEEPER TYPE ‹ monotone

ÌBJ0`Î bitonal

ÌBJ1cÎ BEEPER LENGTH long

ÌBI0^Î ‹ short

ÌBI1aÎ

88

Page 97

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

GOOD READ SPOT DURATION disable

ÌBV0xÎ short

ÌBV1{Î ‹ medium

ÌBV2~Î long

ÌBV3ÅÎ AIMING SYSTEM ‹ disabled

ÌBj09Î enabled

ÌBj1<Î CRADLE BEEPER INTENSITY disable

ÌJI0fÎ low intensity

ÌJI1iÎ medium intensity

ÌJI2lÎ ‹ high intensity

ÌJI3oÎ 89

Page 98

DECODING PARAMETERS ~ ~ ~ ~ ~

INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™

~ ~ ~ ~ ~

Before changing these parameter values read the descriptions in par. 5.7. CAUTION

1. 2. 3.

90

Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. ‹ = Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 99

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DECODING PARAMETERS

Ì$-?Î

INK SPREAD disable

ÌAX0{Î ‹ enable

ÌAX1~Î See par. 5.7.1 for details.

OVERFLOW CONTROL disable

ÌAW1|Î ‹ enable

ÌAW0yÎ See par. 5.7.2 for details.

INTERDIGIT CONTROL disable

ÌAV0wÎ ‹ enable

ÌAV1zÎ See par. 5.7.3 for details.

91

Page 100

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DECODING PARAMETERS

DECODING SAFETY ‹ one read

ÌED0WÎ (decoding safety disabled)

two reads

ÌED1ZÎ three reads

ÌED2]Î four reads

ÌED3`Î Required number of good reads before accepting code.

PUZZLE SOLVER™ ‹ disable

ÌAU0uÎ enable

ÌAU1xÎ In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it. To read codes using this technology, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly. Conditions: •

This parameter is only valid for the following codes: EAN 8 without Add-on

EAN 13 without Add-on

Code 128

Code 39

•

For Code 39, Check digit control is forced.

•

PuzzleSolver™ is not valid for ISBT 128 code.

92

UPC A without Add-on

Page 101

CODE SELECTION ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

AUTO-CONFIGURATION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI CODE 11 CODE 16K CODE 49 RSS CODES

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹

3.

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

93