Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 25

Dragon D131/M131 Reference Manual: 4 CONFIGURATION, pages 82 to 91

Pages 82 to 91 of 212, from Dragon D131/M131 Reference Manual

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic MBC-3000

Page 82

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

DATA FORMAT

For more details see par. 5.4.1 and par. 5.4.2.

TERMINATOR no terminator

ÌEA10-Î one character terminator

ÌEA111Î two character terminator

ÌEA125Î three character terminator

ÌEA139Î four character terminator

ÌEA14=Î five character terminator

ÌEA15AÎ six character terminator

ÌEA16EÎ seven character terminator

ÌEA17IÎ eight character terminator

ÌEA18MÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: two character terminator

+ 0D + 0A = Terminator CR LF

74

Page 83

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

For more details see par. 5.4.1 and par. 5.4.2.

SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces

It is necessary to define each Special Key by following the procedure given in par. 5.4.2. NOTE

Select one or more of the following Special Keys according to your needs. Special Key 1

Ì9CÄÎ Special Key 2

Ì9DÆÎ Special Key 3

Ì9EÈÎ Special Key 4

Ì9FÊÎ Special Key 5

ÌA0bÎ

75

Page 84

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

DATA FORMAT

FIELD ADJUSTMENT ‹ disable field adjustment

ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment:

c Read the enable field adjustment code: enable field adjustment

ÌEF+Î d Select the code type from the Code Identifier Table in Appendix B. e Select the type of adjustment to perform: right addition

Ì01Î left addition

Ì12Î right deletion

Ì23Î left deletion

Ì34Î f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •

Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.

•

If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.

•

You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.

Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment

Read

76

ÌEF+Î

Code 39

+

ÌVWÎ right addition

+

Ì01Î

+

04

Page 85

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

FIELD ADJUSTMENT CHARACTER c Read the field adjustment character code: field adjustment character

ÌEG-Î d Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: To define the field adjustment character = A: field adjustment character

Read

+ 41

CODE LENGTH TX ‹ code length not transmitted

ÌEE0YÎ code length transmitted in variable-digit format

ÌEE1\Î code length transmitted in fixed 4-digit format

ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.

77

Page 86

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

CHARACTER REPLACEMENT ‹ disable character replacement

ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:

c

Read one of the following character replacement codes: first character replacement

ÌEO1pÎ second character replacement

ÌEO2sÎ third character replacement

ÌEO3vÎ d

From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families.

e

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE), which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75.

f

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.

78

Page 87

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DATA FORMAT

Example: The following strings define: 1.

First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.

2.

Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.

first character replacement

Code 39

ÌEO1pÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character 0

30

ASCII characters corresponding to the HEX value for character 1

+

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character replacement

Code 39

ÌEO2sÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character A

41

ASCII characters corresponding to the HEX value for character B

+

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

79

Page 88

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DATA FORMAT

ADDRESS STAMPING (M131 SERIES ONLY) ‹ disable reader address stamping

ÌRU0ÊÎ ‹ disable cradle address stamping

ÌRW0#Î enable reader address stamping

ÌRU1"Î enable cradle address stamping

ÌRW1&Î See par. 5.4.3 for details.

ADDRESS DELIMITER (M131 SERIES ONLY) ‹ disable reader address delimiter

ÌRV0!Î ‹ disable cradle address delimiter

ÌRY0'Î enable reader address delimiter and select characters

ÌRV1$Î enable cradle address delimiter and select characters

ÌRY1*Î Read 2 HEX characters in the range 00-FE.

Read 2 HEX characters in the range 00-FE.

See par. 5.4.4 for details.

80

Page 89

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DATA FORMAT

TIME STAMPING (M131 SERIES ONLY) ‹ disable

ÌIL0kÎ hour/minutes/seconds month/day/year

ÌIL1nÎ hour/minutes/seconds day/month/year

ÌIL2qÎ hour/minutes/seconds

ÌIL3tÎ month/day/year

ÌIL4wÎ day/month/year

ÌIL5zÎ See par. 5.4.5 for details.

TIME STAMPING DELIMITER (M131 SERIES ONLY) ‹ disable

ÌIM0mÎ select delimiter

ÌIM1pÎ Read 2 HEX characters in the range 00-FE. See par. 5.4.6 for details.

81

Page 90

POWER SAVE ~ ~

SLEEP STATE ENTER SLEEP TIMEOUT

~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹

3. 82

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 91

Enter Configuration

Ì$+;Î

Exit and Save Configuration

POWER SAVE

Ì$-?Î

SLEEP STATE ‹ disable

ÌBQ0nÎ enable

ÌBQ1qÎ See par. 5.5.1 for details. For M131 series readers, sleep state is entered immediately after reading a code and is not configurable.

ENTER SLEEP TIMEOUT enter sleep timeout

ÌBR@Î Read 2 numbers in the range 00-99: 00 = Enter Sleep state immediately 01-99 = corresponds to a max. 9.9 sec. delay before entering the Sleep state. ‹ enter sleep timeout = 0.6 sec. See par. 5.5.2 for details.

83