Page 82
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
DATA FORMAT
For more details see par. 5.4.1 and par. 5.4.2.
TERMINATOR no terminator
ÌEA10-Î one character terminator
ÌEA111Î two character terminator
ÌEA125Î three character terminator
ÌEA139Î four character terminator
ÌEA14=Î five character terminator
ÌEA15AÎ six character terminator
ÌEA16EÎ seven character terminator
ÌEA17IÎ eight character terminator
ÌEA18MÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: two character terminator
+ 0D + 0A = Terminator CR LF
74
Page 83
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
For more details see par. 5.4.1 and par. 5.4.2.
SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces
It is necessary to define each Special Key by following the procedure given in par. 5.4.2. NOTE
Select one or more of the following Special Keys according to your needs. Special Key 1
Ì9CÄÎ Special Key 2
Ì9DÆÎ Special Key 3
Ì9EÈÎ Special Key 4
Ì9FÊÎ Special Key 5
ÌA0bÎ
75
Page 84
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
DATA FORMAT
FIELD ADJUSTMENT ‹ disable field adjustment
ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment:
c Read the enable field adjustment code: enable field adjustment
ÌEF+Î d Select the code type from the Code Identifier Table in Appendix B. e Select the type of adjustment to perform: right addition
Ì01Î left addition
Ì12Î right deletion
Ì23Î left deletion
Ì34Î f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •
Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.
•
If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.
•
You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.
Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment
Read
76
ÌEF+Î
Code 39
+
ÌVWÎ right addition
+
Ì01Î
+
04
Page 85
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
FIELD ADJUSTMENT CHARACTER c Read the field adjustment character code: field adjustment character
ÌEG-Î d Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: To define the field adjustment character = A: field adjustment character
Read
+ 41
CODE LENGTH TX ‹ code length not transmitted
ÌEE0YÎ code length transmitted in variable-digit format
ÌEE1\Î code length transmitted in fixed 4-digit format
ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.
77
Page 86
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
CHARACTER REPLACEMENT ‹ disable character replacement
ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:
c
Read one of the following character replacement codes: first character replacement
ÌEO1pÎ second character replacement
ÌEO2sÎ third character replacement
ÌEO3vÎ d
From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families.
e
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE), which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75.
f
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.
78
Page 87
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DATA FORMAT
Example: The following strings define: 1.
First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.
2.
Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.
first character replacement
Code 39
ÌEO1pÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character 0
30
ASCII characters corresponding to the HEX value for character 1
+
31
For Code 39 codes containing the string "0123", the contents transmitted will be "1123".
second character replacement
Code 39
ÌEO2sÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character A
41
ASCII characters corresponding to the HEX value for character B
+
42
For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".
79
Page 88
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DATA FORMAT
ADDRESS STAMPING (M131 SERIES ONLY) ‹ disable reader address stamping
ÌRU0ÊÎ ‹ disable cradle address stamping
ÌRW0#Î enable reader address stamping
ÌRU1"Î enable cradle address stamping
ÌRW1&Î See par. 5.4.3 for details.
ADDRESS DELIMITER (M131 SERIES ONLY) ‹ disable reader address delimiter
ÌRV0!Î ‹ disable cradle address delimiter
ÌRY0'Î enable reader address delimiter and select characters
ÌRV1$Î enable cradle address delimiter and select characters
ÌRY1*Î Read 2 HEX characters in the range 00-FE.
Read 2 HEX characters in the range 00-FE.
See par. 5.4.4 for details.
80
Page 89
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DATA FORMAT
TIME STAMPING (M131 SERIES ONLY) ‹ disable
ÌIL0kÎ hour/minutes/seconds month/day/year
ÌIL1nÎ hour/minutes/seconds day/month/year
ÌIL2qÎ hour/minutes/seconds
ÌIL3tÎ month/day/year
ÌIL4wÎ day/month/year
ÌIL5zÎ See par. 5.4.5 for details.
TIME STAMPING DELIMITER (M131 SERIES ONLY) ‹ disable
ÌIM0mÎ select delimiter
ÌIM1pÎ Read 2 HEX characters in the range 00-FE. See par. 5.4.6 for details.
81
Page 90
POWER SAVE ~ ~
SLEEP STATE ENTER SLEEP TIMEOUT
~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3. 82
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 91
Enter Configuration
Ì$+;Î
Exit and Save Configuration
POWER SAVE
Ì$-?Î
SLEEP STATE ‹ disable
ÌBQ0nÎ enable
ÌBQ1qÎ See par. 5.5.1 for details. For M131 series readers, sleep state is entered immediately after reading a code and is not configurable.
ENTER SLEEP TIMEOUT enter sleep timeout
ÌBR@Î Read 2 numbers in the range 00-99: 00 = Enter Sleep state immediately 01-99 = corresponds to a max. 9.9 sec. delay before entering the Sleep state. ‹ enter sleep timeout = 0.6 sec. See par. 5.5.2 for details.
83