Page 72
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
PEN EMULATION See par. 5.2.3 for details.
OUTPUT LEVEL ‹ normal
ÌDD0VÎ (white = logic level 0)
inverted
ÌDD1YÎ (white = logic level 1) See par. 5.2.4 for details.
IDLE LEVEL ‹ normal
ÌDE0XÎ (black level)
inverted
ÌDE1[Î (white level) See par. 5.2.4 for details.
INTER-BLOCK DELAY delay between character blocks transmitted to Host
ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds ‹ delay disabled See par. 5.2.5 for details.
64
Page 73
NETWORK PARAMETERS OM-3000 model configurations only
~ ~ ~ ~ ~ ~ ~
RS485 NETWORK NETWORK BAUD RATE SLAVE ADDRESS RANGE NETWORK WARNING MESSAGE RECEPTION WARNING MESSAGE MASTER CRADLE HEADER MASTER CRADLE TERMINATOR
~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
65
Page 74
Enter Configuration
Ì$+;Î
Exit and Save Configuration
NETWORK PARAMETERS
Ì$-?Î
RS485 NETWORK ‹ disable RS485 network
ÌRZ0)Î enable RS485 slave
ÌRZ1,Î enable RS485 master
ÌRZ2/Î See par. 3.2 for details.
NOTE
If an OM-3000 cradle is errantly configured as a Slave but not connected to a network, it may not be able to receive further commands from the gun. In this case it can be reconfigured by executing the bind procedure, which returns the cradle to Stand Alone configuration.
NETWORK BAUD RATE 9600
ÌJE0^Î 19200
ÌJE1aÎ ‹ 38400
ÌJE2dÎ
66
Page 75
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
NETWORK PARAMETERS
SLAVE ADDRESS RANGE First Address
ÌJB(Î Read the code above and the four-digit address of the First Slave device in the system.
Last Address
ÌJC*Î Read the code above and the four-digit address of the Last Slave device in the system. See par. 5.3.1 for details.
NETWORK WARNING MESSAGE ‹ network warning message not transmitted
ÌJG0bÎ network warning message transmitted
ÌJG1eÎ See par. 5.3.2 for details.
RECEPTION WARNING MESSAGE reception warning message not transmitted
ÌJH0dÎ ‹ reception warning message transmitted
ÌJH1gÎ See par. 5.3.3 for details.
67
Page 76
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
NETWORK PARAMETERS
MASTER CRADLE HEADER ‹ no header
ÌJA00/Î one character header
ÌJA013Î two character header
ÌJA027Î three character header
ÌJA03;Î four character header
ÌJA04?Î five character header
ÌJA05CÎ six character header
ÌJA06GÎ seven character header
ÌJA07KÎ eight character header
ÌJA08OÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range:
00-FE
Example: four character header
+ 41 + 42 + 43 + 44 = Header ABCD
For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.
68
Page 77
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
NETWORK PARAMETERS
MASTER CRADLE TERMINATOR ‹ no terminator
ÌJA102Î one character terminator
ÌJA116Î two character terminator
ÌJA12:Î three character terminator
ÌJA13>Î four character terminator
ÌJA14BÎ five character terminator
ÌJA15FÎ six character terminator
ÌJA16JÎ seven character terminator
ÌJA17NÎ eight character terminator
ÌJA18RÎ After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Valid characters are in the range:
00-FE
Example: two character terminator
+ 0D + 0A = Terminator CR LF
For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.
69
Page 78
DATA FORMAT NOT FOR PEN INTERFACES
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR SPECIAL KEYS FIELD ADJUSTMENT FIELD ADJ. CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER TIME STAMPING TIME DELIMITER
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹
3. 70
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 79
DATA FORMAT CODE IDENTIFIER TABLE CODE 2/5 interleaved 2/5 industrial 2/5 normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPC A with 2 ADD ON UPC A with 5 ADD ON UPC E with 2 ADD ON UPC E with 5 ADD ON Code 39 Code 39 Full ASCII CODABAR ABC CODABAR Code 128 EAN 128
ISBT 128 Code 93 CIP/39 CIP/HR Code 32 MSI Code 11 Code 16K Code 49 RSS Expanded Linear and Stacked RSS Limited RSS 14 Linear and Stacked
AIM STANDARD
DATALOGIC STANDARD
]Iy ]Xy ]Sy ]Xy ]E4 ]E0 ]Xy ]Xy ]E5 ]E6 ]E1 ]E2 ]Xy ]Xy ]Xy ]Xy ]Ay ]Ay ]Fy ]Xy ]Cy ]Cy ] C4 ]Gy ]Xy ]Xy ]Xy ]My ]Hy ]K0 ]Ty ]e0 ]e0 ]e0
N P O Q A B C D J K L M F G H I V W R S T k f U Y e X Z b p q t v u
Custom
•
AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.).
•
When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled).
•
The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character.
•
Write in the Custom character identifiers in the table above for your records.
71
Page 80
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DATA FORMAT
CODE IDENTIFIER ‹ disable
ÌEB0SÎ Datalogic standard
ÌEB1VÎ AIM standard
ÌEB2YÎ custom
ÌEB3\Î CUSTOM CODE IDENTIFIER define custom code identifier(s)
ÌEH/Î c Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page). d
Select the code type from the code table in Appendix B for the identifier you want to change.
e You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step d: valid characters are in the range 00-FD.
Example:
To define Code 39 Code Identifier = @ define custom code identifier(s)
Read
72
ÌEH/Î
Code 39
+
ÌVWÎ +
40
+
FF
Page 81
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
DATA FORMAT
HEADER no header
ÌEA00*Î one character header
ÌEA01.Î two character header
ÌEA022Î three character header
ÌEA036Î four character header
ÌEA04:Î five character header
ÌEA05>Î six character header
ÌEA06BÎ seven character header
ÌEA07FÎ eight character header
ÌEA08JÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: four character header
+ 41 + 42 + 43 + 44 = Header ABCD
73