Page 72

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

PEN EMULATION See par. 5.2.3 for details.

OUTPUT LEVEL ‹ normal

ÌDD0VÎ (white = logic level 0)

inverted

ÌDD1YÎ (white = logic level 1) See par. 5.2.4 for details.

IDLE LEVEL ‹ normal

ÌDE0XÎ (black level)

inverted

ÌDE1[Î (white level) See par. 5.2.4 for details.

INTER-BLOCK DELAY delay between character blocks transmitted to Host

ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds ‹ delay disabled See par. 5.2.5 for details.

64

Page 73

NETWORK PARAMETERS OM-3000 model configurations only

~ ~ ~ ~ ~ ~ ~

RS485 NETWORK NETWORK BAUD RATE SLAVE ADDRESS RANGE NETWORK WARNING MESSAGE RECEPTION WARNING MESSAGE MASTER CRADLE HEADER MASTER CRADLE TERMINATOR

~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

65

Page 74

Enter Configuration

Ì$+;Î

Exit and Save Configuration

NETWORK PARAMETERS

Ì$-?Î

RS485 NETWORK ‹ disable RS485 network

ÌRZ0)Î enable RS485 slave

ÌRZ1,Î enable RS485 master

ÌRZ2/Î See par. 3.2 for details.

NOTE

If an OM-3000 cradle is errantly configured as a Slave but not connected to a network, it may not be able to receive further commands from the gun. In this case it can be reconfigured by executing the bind procedure, which returns the cradle to Stand Alone configuration.

NETWORK BAUD RATE 9600

ÌJE0^Î 19200

ÌJE1aÎ ‹ 38400

ÌJE2dÎ

66

Page 75

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

NETWORK PARAMETERS

SLAVE ADDRESS RANGE First Address

ÌJB(Î Read the code above and the four-digit address of the First Slave device in the system.

Last Address

ÌJC*Î Read the code above and the four-digit address of the Last Slave device in the system. See par. 5.3.1 for details.

NETWORK WARNING MESSAGE ‹ network warning message not transmitted

ÌJG0bÎ network warning message transmitted

ÌJG1eÎ See par. 5.3.2 for details.

RECEPTION WARNING MESSAGE reception warning message not transmitted

ÌJH0dÎ ‹ reception warning message transmitted

ÌJH1gÎ See par. 5.3.3 for details.

67

Page 76

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

NETWORK PARAMETERS

MASTER CRADLE HEADER ‹ no header

ÌJA00/Î one character header

ÌJA013Î two character header

ÌJA027Î three character header

ÌJA03;Î four character header

ÌJA04?Î five character header

ÌJA05CÎ six character header

ÌJA06GÎ seven character header

ÌJA07KÎ eight character header

ÌJA08OÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range:

00-FE

Example: four character header

+ 41 + 42 + 43 + 44 = Header ABCD

For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.

68

Page 77

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

NETWORK PARAMETERS

MASTER CRADLE TERMINATOR ‹ no terminator

ÌJA102Î one character terminator

ÌJA116Î two character terminator

ÌJA12:Î three character terminator

ÌJA13>Î four character terminator

ÌJA14BÎ five character terminator

ÌJA15FÎ six character terminator

ÌJA16JÎ seven character terminator

ÌJA17NÎ eight character terminator

ÌJA18RÎ After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Valid characters are in the range:

00-FE

Example: two character terminator

+ 0D + 0A = Terminator CR LF

For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.4, 5.4.1 and 5.4.2.

69

Page 78

DATA FORMAT NOT FOR PEN INTERFACES

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR SPECIAL KEYS FIELD ADJUSTMENT FIELD ADJ. CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER TIME STAMPING TIME DELIMITER

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given ‹

3. 70

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 79

DATA FORMAT CODE IDENTIFIER TABLE CODE 2/5 interleaved 2/5 industrial 2/5 normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPC A with 2 ADD ON UPC A with 5 ADD ON UPC E with 2 ADD ON UPC E with 5 ADD ON Code 39 Code 39 Full ASCII CODABAR ABC CODABAR Code 128 EAN 128

ISBT 128 Code 93 CIP/39 CIP/HR Code 32 MSI Code 11 Code 16K Code 49 RSS Expanded Linear and Stacked RSS Limited RSS 14 Linear and Stacked

AIM STANDARD

DATALOGIC STANDARD

]Iy ]Xy ]Sy ]Xy ]E4 ]E0 ]Xy ]Xy ]E5 ]E6 ]E1 ]E2 ]Xy ]Xy ]Xy ]Xy ]Ay ]Ay ]Fy ]Xy ]Cy ]Cy ] C4 ]Gy ]Xy ]Xy ]Xy ]My ]Hy ]K0 ]Ty ]e0 ]e0 ]e0

N P O Q A B C D J K L M F G H I V W R S T k f U Y e X Z b p q t v u

Custom

•

AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.).

•

When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled).

•

The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character.

•

Write in the Custom character identifiers in the table above for your records.

71

Page 80

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DATA FORMAT

CODE IDENTIFIER ‹ disable

ÌEB0SÎ Datalogic standard

ÌEB1VÎ AIM standard

ÌEB2YÎ custom

ÌEB3\Î CUSTOM CODE IDENTIFIER define custom code identifier(s)

ÌEH/Î c Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page). d

Select the code type from the code table in Appendix B for the identifier you want to change.

e You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step d: valid characters are in the range 00-FD.

Example:

To define Code 39 Code Identifier = @ define custom code identifier(s)

Read

72

ÌEH/Î

Code 39

+

ÌVWÎ +

40

+

FF

Page 81

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

DATA FORMAT

HEADER no header

ÌEA00*Î one character header

ÌEA01.Î two character header

ÌEA022Î three character header

ÌEA036Î four character header

ÌEA04:Î five character header

ÌEA05>Î six character header

ÌEA06BÎ seven character header

ÌEA07FÎ eight character header

ÌEA08JÎ After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 75. Example: four character header

+ 41 + 42 + 43 + 44 = Header ABCD

73