Page 102

Code selections may be performed according to two different procedures: -

Auto-configuration, allowing an automatic recognition and selection of the code families to be read;

-

Manual configuration, requiring configuration and selection of each code family to be read.

AUTO-CONFIGURATION The following codes do not require reading the Enter and Exit configuration codes. In auto-configuration mode the reader enters a particular state, during which it reads, recognizes and saves all information received from the decoding of an existing code (with the exception of MSI, Code 49 and Code 16k code types). In this way, the code families will be automatically configured. It is possible to configure up to 10 code types, whose length is variable and check digit ignored. If reading different codes belonging to the same family, information about the last code will overwrite the information about the previous one. Follow the given procedure to auto-configure the desired code families:

If no code is read during the auto-configuration procedure (step d), the configuration will be empty and therefore the reader will be unable to read codes. CAUTION c Read the following code to enter the auto-configuration mode: auto-configuration

Ì#+AUTOWÎ d

Read an existing code belonging to the code families that you need to configure.

e Read the following code to save the configuration automatically and return to the reader's normal functioning: save auto-configuration

Ì$-?Î If you need to change the configuration, repeat the auto-configuration procedure, follow the manual configuration by setting the parameters for each single code family or read the "Restore Default" code on page 164. Be careful that in the latter case all reader parameters will be restored.

94

Page 103

Enter Configuration

Exit and Save Configuration

Ì$+;Î

CODE SELECTION

Ì$-?Î

DISABLE ALL CODE FAMILIES

ÌAZ0ÃÎ

The reader allows up to 10 code selections. This does not limit the number of CODES enabled to 10, as it depends on the code family. NOTE

SINGLE SELECTIONS =

•

ONE combination code from the EAN family

•

ONE code from the 2/5 family

Example 5 code selections:

1. 2/5 Interleaved 2. 2/5 Industrial 3. Code 128 + EAN 128 4. Code 39 Full ASCII + Code 32 5. UPC A/UPC E 6. etc.

In this section all SINGLE code selections are underlined and in bold.

95

Page 104

Enter Configuration

Exit and Save Configuration

Ì$+;Î

CODE SELECTION

Ì$-?Î

EAN/UPC FAMILY disable the family

ÌAA0MÎ c Read the desired family code Note: Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable another selection, first disable the family. EAN 8/EAN 13/UPC A/UPC E with and without ADD ON

ÌAA8eÎ WITHOUT ADD ON ‹ EAN 8/EAN 13/UPC A/UPC E

ÌAA1PÎ EAN 8/EAN 13

ÌAA3VÎ UPC A/UPC E

ÌAA4YÎ WITH ADD ON 2 AND 5 EAN 8/EAN 13/UPC A/UPC E

ÌAA5\Î EAN 8/EAN 13

ÌAA6_Î UPC A/UPC E

ÌAA7bÎ

96

Page 105

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

WITH ADD ON 2 ONLY EAN 8/EAN 13

ÌAAK7Î UPC A/UPC E

ÌAAM=Î WITH ADD ON 5 ONLY EAN 8/EAN 13

ÌAAL:Î UPC A/UPC E

ÌAAN@Î WITH AND WITHOUT ADD ON

‹ EAN/UPC with and without ADD ON no Autodiscrimination

ÌAA8Ad03Î EAN/UPC Autodiscrimination ADD ON by Prefix

ÌAA8Ad19Î By setting the EAN/UPC Autodiscrimination ADD ON by Prefix, the desired prefixes must be selected by reading the corresponding codes given in the following section, since no prefix is configured by default.

97

Page 106

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

CODE SELECTION SELECT EAN/UPC PREFIXES

NOTE

When scanning the following codes, barcodes starting with the selected prefixes will be read and transmitted only if the ADD ON is present. If no ADD ON is found, the barcode will not be read. Barcodes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON.

‹ Cancel All Selections

ÌET0wÎ OR select one or more of the following prefixes: 378/379

ÌET1378ET2379PÎ 434/439

ÌET3434ET4439ÉÎ 414/419

ÌET5414ET6419}Î 977

ÌET7977QÎ 978

ÌET8978ZÎ 979

ÌET9979cÎ The commands above are not mutually exclusive. They can be used to configure more than one set of prefixes simultaneously.

98

Page 107

Enter Configuration

Exit and Save Configuration

Ì$+;Î

CODE SELECTION

Ì$-?Î

Example: The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the 434/439, 977 and 978 prefixes: 1.

EAN/UPC Autodiscrimination ADD ON by Prefix.

2.

434/439: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting with 434/439 prefixes.

3.

977: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting with 977 prefix.

4.

978: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting with 978 prefix. EAN/UPC Autodiscrimination ADD ON by Prefix

434/439

ÌAA8Ad19Î + ÌET3434ET4439ÉÎ 977

+

+

978

ÌET7977QÎ + ÌET8978ZÎ

To clear the current prefix selections: 1.

Cancel all Selections Cancel All Selections

ÌET0wÎ

99

Page 108

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

CODE SELECTION EAN/UPC CHECK DIGIT TX SELECTIONS

For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION NO CHECK DIGIT TRANSMISSION ‹ EAN 8

ÌAAG1oÎ EAN 8

ÌAAG0kÎ ‹ EAN 13

ÌAAH1rÎ EAN 13

ÌAAH0nÎ ‹ UPC A

ÌAAI1uÎ UPC A

ÌAAI0qÎ ‹ UPC E

ÌAAJ1xÎ UPC E

ÌAAJ0tÎ

100

Page 109

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CONVERSION OPTIONS UPC E to UPC A conversion

ÌAAAÄÎ UPC E to EAN 13 conversion

ÌAABÇÎ UPC A to EAN 13 conversion

ÌAACÊÎ EAN 8 to EAN 13 conversion

ÌAAD"Î Enable only ISBN conversion

ÌAP1nÎ Enable only ISSN conversion

ÌAP2qÎ Enable both ISBN and ISSN conversion

ÌAP3tÎ Disable both ISBN and ISSN conversion

ÌAP0kÎ

101

Page 110

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

CODE SELECTION

2/5 FAMILY disable the family

ÌAC0QÎ c Read the desired family code d Read a check digit selection

‹ Interleaved 2/5

ÌAC1TÎ

CHECK DIGIT TABLE no check digit control

Ì12Î Normal 2/5 (5 Bars)

ÌAC2WÎ ‹ check digit control and transmission

Ì23Î Industrial 2/5 (IATA)

ÌAC3ZÎ check digit control without transmission

Ì34Î Matrix 2/5 (3 Bars)

ÌAC4]Î e Read 4 numbers for the code length − −

The pharmaceutical code below is part of the 2/5 family but has no check digit or code length selections. Code CIP/HR

ÌAC5`Î French pharmaceutical code

102 where: First 2 digits = minimum code length. Second 2 digits = maximum code length.

The maximum characters.

code length is 99

The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.

Page 111

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CODE 39 FAMILY disables the family

ÌAB0OÎ d Read a check digit selection c Read the desired family code

CHECK DIGIT TABLE ‹ Standard Code 39

‹ no check digit control

ÌAB1RÎ

Ì12Î

Full ASCII Code 39 check digit control and transmission

ÌAB2UÎ

Ì23Î check digit control without transmission

Ì34Î The pharmaceutical codes below are part of the Code 39 family but have no check digit selections. Code CIP39

ÌAB3XÎ French pharmaceutical code

Code 32

ÌAB4[Î Italian pharmaceutical code CODE LENGTH (optional) The code length selection is valid for the entire Code 39 family Read the code + 4 numbers for the code length where: First 2 digits = minimum code length. Second 2 digits = maximum code length.

set code length

ÌAB*=Î

The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum.

103