Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 15

Matrix 400 Reference Manual, pages 81 to 90

Pages 81 to 90 of 147

The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic Matrix-400

Page 81

MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS

5.5.2

5

ID-NET™ Response Time

The following figure shows the response time of the ID-NET™ network. This time is defined as the period between the Trigger activation and the beginning of data transmission to the Host. Max ID-NET™ Response Time 240 220 200

Response Time (ms)

180 160 140 120 100 80 60 40 20 0 0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Number of Nodes 500 kbps

250 kbps

125 kbps

Figure 82 – ID-NET™ Response Time

CONDITIONS:

ID-NET™ M/S Synchronized layout message length = 50 bytes per node

71

Page 82

5

MATRIX 400™ REFERENCE MANUAL

Figure 83 – ID-NET™ Network Connections with isolated power blocks

72

Page 83

MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS

5

Figure 84 - ID-NET™ Network Connections with Common Power Branch Network

73

Page 84

5

MATRIX 400™ REFERENCE MANUAL

Figure 85 – ID-NET™ Network Connections with Common Power Star Network

74

Page 85

MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS

5.5.3

5

ID-NET™ Network Termination

The network must be properly terminated by a 120 Ohm resistor at the first and last reader of the network.

5.6 AUXILIARY RS232 INTERFACE The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave connections. When it is connected to the host computer it allows both transmission of code data and reader configuration by VisiSet™. The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular communication modes such as LOCAL ECHO can be defined through the Communication folder of the VisiSet™ utility program. The following pins of the M16 19-pin connector are used for auxiliary interface communication: Pin O S L

Name TX RX GND

Function Transmitted data Received data Ground

MATRIX RX TX GND Chassis

SHIELD

Earth Ground

USER INTERFACE S O L

TXD RXD Ground

K

Earth Ground

Figure 86 - RS232 Auxiliary Interface Connections Using 19-pin Connector

75

Page 86

MATRIX 400™ REFERENCE MANUAL

5

5.7 ETHERNET INTERFACE (MATRIX 400 XXX-010 MODELS ONLY) The Ethernet Interface can be used for TCP/IP communication with a remote or local host computer by connecting the reader to either a LAN or directly to a host PC. The following is an example of a connection to a LAN using a CAB-ETH-M0x straight through cable: M12 D-Coded Connector Pinout Pin 1 2 3 4

Name TX+ RX+ TXRX-

Function Transmitted data (positive pin) Received data (positive pin) Transmitted data (negative pin) Received data (negative pin)

MATRIX

LAN

M12 D-coded

TX+

1

1

TX+

RX+

2

3

RX+

TX-

3

2

TX-

RX-

4

6

RX-

RJ45

4 5 7 8

Figure 87 - Straight-Through Cable

For direct connection to a PC use the CAB-ETH-M0x cable with a crossover adapter. On the Matrix 400™ Ethernet interface the following communication channels are available:

Data Socket

Image Socket

WebSentinel Socket

Image FTP Client

HTTP Server

Email Client

Ethernet IP

For further details refer to the Ethernet Folder in the VisiSet™ Help On Line and to the "Matrix Ethernet Service Guide.pdf" document provided as supplementary documentation.

76

Page 87

MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS

5

5.8 INPUTS There are two optocoupled polarity insensitive inputs available on the M16 19-pin connector of the reader: Input 1 (External Trigger) and Input 2, a generic input: The External Trigger can be used in One Shot Mode or in Phase Mode. Its main functions are: acquisition trigger in One Shot Mode reading phase-ON/reading phase-OFF command in Phase Mode The main functions of the general purpose Input 2 are: second external trigger in Phase Mode match code storage command when the Match Code option is enabled The electrical features of both inputs are: INPUT Open Closed

| V AB | Min. 0V 4.5 V

| V AB | Max. 2V 30 V

I IN Max. 0 mA 10 mA

The active state of these inputs are selected in software. Refer to the VisiSet™ Help On Line. An anti-disturbance filter is implemented in software on both inputs so that the minimum pulse duration is 0.5 milliseconds. This value can be increased through the software parameter Debounce Filter, see the Digital I/O folder in the VisiSet™ Help On Line for further details. These inputs are optocoupled and can be driven by both NPN and PNP type commands.

Polarity insensitive inputs assure full functionality even if pins A and B are exchanged. NOTE

The connections are indicated in the following diagrams: Pin A B C L

Name Vdc I1A I1B GND

Function Power Supply input voltage + External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) Power Supply input voltage -

The yellow Trigger LED (Figure 19, 5) is on when the active state of the External Trigger corresponds to ON.

77

Page 88

MATRIX 400™ REFERENCE MANUAL

5

EXTERNAL TRIGGER INPUT PNP PH-1 Matrix 400™

VCC

PNP PH-1 wires

~ + ~

A

Vdc

(brown) +10-30 Vdc

B

I1A

(black) NO

C

I1B

L

GND

(blue) 0 V

Figure 88 - External Trigger Using PNP PH-1 Photocell

EXTERNAL TRIGGER INPUT CONNECTIONS USING MATRIX 400™ POWER EXTERNAL TRIGGER

Matrix 400™

VCC

+

~ ~

A

Vdc

B

I1A

C

I1B

L

GND

V Signal

Ground

Figure 89 – External Trigger PNP Using Matrix 400™ Power

Matrix 400™

VCC

EXTERNAL TRIGGER

~ + ~

A

Vdc

B

I1A

C

I1B

L

GND

V

Signal Ground

Figure 90 - External Trigger NPN Using Matrix 400™ Power

EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER Vext 30 Vdc max. EXTERNAL TRIGGER

Matrix 400™

V

VCC

+

~ ~

-

A

I1A

B

I1B

Signal I in

Figure 91 - External Trigger PNP Using External Power

78

Page 89

MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS

Vext 30 Vdc max. EXTERNAL TRIGGER

Matrix 400™

VCC

+

~ ~

-

5

A

I1A

B

I1B

V

Signal

Figure 92 - External Trigger NPN Using External Power

Pin A D E L

Name Vdc I2A I2B GND

Function Power Supply input voltage + Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) Power Supply input voltage -

INPUT 2 CONNECTIONS USING MATRIX 400™ POWER INPUT DEVICE

Matrix 400™

VCC

+

~ ~

A

Vdc

D

I2A

E

I2B

L

GND

V Signal

Ground

Figure 93 - Input PNP Using Matrix 400™ Power

Matrix 400™

VCC

~ + ~

INPUT DEVICE A

Vdc

D

I2A

E

I2B

L

GND

V

Signal Ground

Figure 94 - Input NPN Using Matrix 400™ Power

79

Page 90

MATRIX 400™ REFERENCE MANUAL

5

INPUT 2 CONNECTIONS USING EXTERNAL POWER Vext 30 Vdc max. INPUT DEVICE

Matrix 400™

V

VCC

+

~ ~

-

D

I2A

E

I2B

Signal I in

Figure 95 - Input PNP Using External Power

Vext 30 Vdc max. INPUT DEVICE

Matrix 400™

VCC

+

~ ~

-

D

I2A

E

I2B

V

Signal

Figure 96 - Input NPN Using External Power

5.9 OUTPUTS Two opto-coupled general purpose outputs are available on the M16 19-pin connector. The meaning of the two outputs Output 1 and Output 2 can be defined by the user. They are typically used either to signal the data collection result or to control an external lighting system. The pinout is the following: Pin H F G I

Name O1+ O1O2+ O2-

Function Configurable digital output 1 - positive pin Configurable digital output 1 - negative pin Configurable digital output 2 - positive pin Configurable digital output 2 - negative pin

The electrical features of the two outputs are the following: OUTPUT Open Closed

ILoad 0 mA 10 mA

VOut 30 Vdc Max 1.8 Vdc Max

PD = VOut IoLoad = 170 mW Max. By default, Output 1 is associated with the Partial Read and No Read events, which activates when the code(s) signaled by the external trigger are not decoded, and Output 2 is associated with the Complete Read event, which activates when all the selected codes are correctly decoded.

80