Page 91
MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS
5
The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to the Digital I/O folder in the VisiSet™ Help On Line for further details. MATRIX
USER INTERFACE Vext 30 Vdc max
H/G V Out
I Load
F/I
Figure 97 - Open Emitter Output Connection
MATRIX
USER INTERFACE Vext 30 Vdc max
H/G F/I
V Out
I Load
Figure 98 - Open Collector Output Connection
81
Page 92
MATRIX 400™ REFERENCE MANUAL
5
5.10 USER INTERFACE RS232 PC-side connections 5
1
6
9
9-pin male connector
Pin 2 3 5 7 8
Name RX TX GND RTS CTS
1
13
14
25
25-pin male connector
Pin 3 2 7 4 5
Name RX TX GND RTS CTS
How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (pushbutton) trigger and PC RS232 COM port connections.
M16 19-pin female
Matrix 400™
9-pin D-sub female
O
TX
2
RX
S
RX
3
TX
5
GND
L
GND
A
Vdc
B
I1A
C I1B
Power Supply Power GND VS (10 – 30 VDC)
Trigger
Figure 99- Test Cable for Matrix 400™
82
PC
Page 93
TYPICAL LAYOUTS
6
6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. However, they also require the correct setup of the software configuration parameters. Dotted lines in the figures refer to optional hardware configurations within the particular layout.
6.1 POINT-TO-POINT In this layout the data is transmitted to the Host on the main serial interface. The RS232 auxiliary interface can be used for reader configuration by connecting a laptop computer running VisiSet™. Host Mode programming can be accomplished either through the main interface or the Auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (for example a pulse from a photoelectric sensor) when the object enters its reading zone.
PG6000
Host
CBX 1
CAB-MSxx Matrix 400™ 2 Terminal
3
Main Serial Interface (RS232 or RS485 Full-Duplex) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Figure 100 – Serial Interface Point-to-Point Layout
83
Page 94
MATRIX 400™ REFERENCE MANUAL
6
In this layout the data is transmitted to the Host on the TCP/IP Ethernet interface (CBX500 with BM200/210 Host Interface Module installed). The RS232 auxiliary interface can be used for reader configuration by connecting a laptop computer running VisiSet™. Host Mode programming can be accomplished either through the TCP/IP Ethernet interface or the Auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the TCP/IP Ethernet selection. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (for example a pulse from a photoelectric sensor) when the object enters its reading zone. Power CBX500 1
Matrix 200™ 2
3
BM200/210 TCP/IP Ethernet Interface Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Host
Figure 101 – BM200/210 TCP/IP Ethernet Interface Point-to-Point Layout
84
Page 95
TYPICAL LAYOUTS
6
In this layout a single reader functions as a Slave node on a Fieldbus network. The data is transmitted to the Host through an accessory Fieldbus interface board installed inside the CBX500 connection box. Reader configuration can be accomplished through the Auxiliary interface using the VisiSet™ configuration program or Host Mode programming. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the Fieldbus interface selection. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
Power CBX500 1
Matrix 400™ 2 3
Host
Fieldbus Interface (Profibus, DeviceNet, etc.) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Figure 102 – Fieldbus Interface Point-to-Point Layout
85
Page 96
MATRIX 400™ REFERENCE MANUAL
6
6.2 PASS-THROUGH 6.2.1
Pass-Through on RS232
Pass-through mode allows two or more devices to be connected to a single external serial interface. Each reader transmits the messages received by the Auxiliary interface onto the Main interface. All messages will be passed through this chain to the host. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (for example a pulse from a photoelectric sensor) when the object enters its reading zone. Applications can be implemented to connect a device such as a hand-held reader to the Auxiliary port of the last reader in the chain for manual code reading capability. The Main and Auxiliary ports are connected as shown in the figure below: 1
2
1
Device#1
2
Device#2
3
1
Device#n
3
2
Power Host
3
Main Serial Interface (RS232 only) Auxiliary Serial Interface (RS232) External Trigger (for One Shot or Phase Mode)
Figure 103 – Pass-Through Layout
The reading device connected to the Host can be connected to a Fieldbus network using a Host Interface module through a CBX500 connection box. NOTE
86
Page 97
TYPICAL LAYOUTS
6.2.2
6
Pass-Through on ID-NET™
An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. This layout is really an ID-NET Master/Slave Multidata layout which also allows each reader (Master and Slaves) to accept input on the Auxiliary interface, for example to connect a device such as a hand-held reader for manual code reading capability. Each Matrix 400™ transmits its own messages plus any messages received by its Auxiliary interface onto the ID-NET™ interface. The Master passes all messages to the Host. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
1
4
Master
Slave#2
3
Slave#n
3
Power
3
2
2
Host
Main Serial Interface (RS232 or RS485) Auxiliary Serial Interface (RS232) External Trigger (for One Shot or Phase Mode) ID-NET™ Figure 104 – Pass-Through On ID-NET™ Layout
The reading device connected to the Host can be connected to a Fieldbus network using a Host Interface module through a CBX500 connection box. NOTE
87
Page 98
MATRIX 400™ REFERENCE MANUAL
6
6.3 ID-NET™ The ID-NET™ connection is used to collect data from several readers to build a multi-point or a multi-sided reading system; there can be one master and up to 31 slaves connected together. The slave readers are connected together using the ID-NET™ interface. Every slave reader must have an ID-NET™ address in the range 1-31. The master reader is also connected to the Host on the RS232/RS485 main serial interface. For a Master/Slave Synchronized layout the External Trigger signal is unique to the system; there is a single reading phase and a single message from the master reader to the Host computer. It is not necessary to bring the External Trigger signal to all the readers. In the Master/Slave Synchronized layout the Master operating mode can only be set to Phase Mode. The main, auxiliary, and ID-NET™ interfaces are connected as shown in the following figures. 1
3
Slave#1
Slave#n
2
Power
Master Host
Main Serial Interface (RS232 or RS485) External Trigger ID-NET™ (up to 16 devices - practical limit)
Figure 105 – ID-NET™ M/S Synchronized Layout
The Master reader can be connected to the CBX series connection box with the advantage of the Backup and Restore configuration function (CBX + BM100 module). If the Backup and Restore function is not required, then a QL300 or QL500 can be used to connect the master reader.
88
Page 99
TYPICAL LAYOUTS
6 CAB-AUX03 ID-NET™
CAB-AUX03
QL150
QL150
CBL-1480-xx
CBL-1480-xx
CBL-1480-xx
Slave Nodes
CBL-1490 ID-NET Terminator Master
The ID-NET network must be terminated through the internal switch of the CBX500 and inserting an ID-NET terminator into the last QL in the network.
PS Power CAB-PW-EXT
3 1 4
CBX500 1
Host
5
BA600 ID-NET™ Out BA400 Ext. Power BA500 Trigger BA300 Service
Main
CAB-AUX03
Figure 106 - ID-NET™ Synchronized Layout Matrix 400™ Master with CBX500 + Matrix 400™ Slaves with QL150
QL300 1
CBL-1496 ID-NET Terminator
CAB-AUX03 ID-NET™
CAB-AUX03
QL150
QL150
CBL-1480-xx
Slave Nodes
CBL-1480-xx
Master
CBL-1490 ID-NET Terminator
The ID-NET network must be terminated inserting an ID-NET terminator into the QL300 (Master) and into the last QL in the network.
PS Power CAB-PW-EXT
Host
Main Interface
Figure 107 - ID-NET™ Synchronized Layout Matrix 400™ Master with QL300 + Matrix 400™ Slaves with QL150
89
Page 100
MATRIX 400™ REFERENCE MANUAL
6
The same configuration can be made to a Host using a TCP/IP Ethernet interface. In this case the Master is connected to a CBX500 with BM200/210 Host Interface Module installed. The TCP/IP Ethernet, auxiliary, and ID-NET™ interfaces are connected as shown in the figure below. 3
Power
Slave#1 CBX500
1
Slave#n
2
Master
Host
BM200/210 TCP/IP Ethernet Interface External Trigger ID-NET™ (up to 16 devices - practical limit)
Figure 108 – ID-NET™ M/S Synchronized Layout with BM200/210 TCP/IP Ethernet Interface to Host
90