The text of a manual · part 11 of 15
Matrix 400 Reference Manual, pages 101 to 110
Pages 101 to 110 of 147
The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic Matrix-400
Page 101
TYPICAL LAYOUTS
6
For a Master/Slave Multidata layout each reader has its own reading phase independent from the others; each single message is sent from the master reader to the Host computer. 1
4
Master
Slave#1
Slave#n 2 Terminal
3
Power
Host
Main Serial Interface (RS232 or RS485) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode) ID-NET™ (up to 32 devices, max network extension of 1000 m)
Figure 109 – ID-NET™ M/S Multidata
The auxiliary serial interface of the slave readers can be used in Local Echo communication mode to control any single reader (visualize collected data) or to configure it using the VisiSet™ utility. NOTE
The ID-NET™ termination resistor switches must be set to ON only in the first and last CBX connection box.
91
Page 102
MATRIX 400™ REFERENCE MANUAL
6
The same configuration can be made to a Host using a TCP/IP Ethernet interface. In this case the Master is connected to a CBX500 with BM200/210 Host Interface Module installed. The TCP/IP Ethernet, auxiliary, and ID-NET™ interfaces are connected as shown in the figure below. 4
Power CBX500
Master
1
Slave#1
Slave#n 2 Terminal
3
Host BM200/210 TCP/IP Ethernet Interface Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode) ID-NET™ (up to 32 devices, max network extension of 1000 m) Figure 110 – ID-NET™ M/S Multidata Layout with BM200/210 TCP/IP Ethernet Interface to Host
The auxiliary serial interface of the slave readers can be used in Local Echo communication mode to control any single reader (visualize collected data) or to configure it using the VisiSet™ utility. NOTE
92
The ID-NET™ termination resistor switches must be set to ON only in the first and last CBX connection box.
Page 103
TYPICAL LAYOUTS
6
Alternatively, the Master reader can communicate to the Host as a Slave node on a Fieldbus network. This requires using an accessory Fieldbus interface board installed inside the CBX500 connection box. System configuration can be accomplished through the Auxiliary interface of each individual reader (internal CBX500 9-pin connector) using the VisiSet™ configuration program or Host Mode programming. See par. 2.3.1 for details.
3
Power Slave#1
Slave#n
2
Master
1
Host
Fieldbus Interface External Trigger (for One Shot or Phase Mode) ID-NET™ (up to 16 devices - practical limit)
Figure 111 – ID-NET™ Fieldbus M/S Synchronized Layout
4
Power
Master
Slave#1
Slave#n 2 Terminal
3
1
Host
Fieldbus Interface Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode) ID-NET™ (up to 32 devices, max network extension of 1000 m)
Figure 112 – ID-NET™ Fieldbus M/S Multidata
93
Page 104
MATRIX 400™ REFERENCE MANUAL
6
6.4 RS232 MASTER/SLAVE This interface is provided for backward compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. NOTE The RS232 master/slave connection is used to collect data from several readers to build either a multi-point or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The Slave readers use RS232 only on the main and auxiliary serial interfaces. Each slave reader transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the Master. The Master reader is connected to the Host on the RS232/RS485 main serial interface. There is a single reading phase and a single message from the master reader to the Host computer. In this layout the Master operating mode can be set only to Phase Mode. The Phase ON/OFF signals must be brought only to the Master. It is not necessary to bring them to the Slave readers. The main and auxiliary ports are connected as shown in the figure below. 1
2
1
2
Slave#1
1
Slave#n
3
Power
Master Host
Main Serial Interface (Slaves RS232 only) Auxiliary Serial Interface (RS232) External Trigger
Figure 113 – RS232 Master/Slave Layout
94
Page 105
TYPICAL LAYOUTS
6
6.5 MULTIPLEXER This interface is provided for backward compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts. NOTE Each reader is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface through a CBX connection box. Before proceeding with the connection it is necessary to select the MUX32 communication protocol and the multidrop address for each reader.
1
0
1
31
2
2
3
MX4000
3
2 3
Power Host
Main Serial Interface (RS485 Half-Duplex) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Figure 114 - Multiplexer Layout
The auxiliary serial interface of the slave readers can be used in Local Echo communication mode to control any single reader (visualize collected data) or to configure it using the VisiSet™ utility. Each reader has its own reading phase independent from the others. When One Shot or Phase Mode operating mode is used, the reader can be activated by an External Trigger (for example a pulse from a photoelectric sensor) when the object enters its reading zone.
95
Page 106
MATRIX 400™ REFERENCE MANUAL
6
6.6 ETHERNET CONNECTION (Matrix 400 XXX-010 models only) For Matrix 400 XXX-010 models, the Ethernet connection is possible in two different layouts. In both layouts, before proceeding with the connection, it is necessary to configure the reader Ethernet parameters via VisiSet™. For further details, see the Ethernet Folder in the VisiSet™ Help On Line. In a Point-to-Point layout the reader is connected to a local host by using a CAB-ETH-M0x cable with a crossover adapter. Crossover Adapter
CAB-ETH-M0x 1
CBX CAB-MS0x
Host Matrix 400™
PG 6000
3
2
Ethernet Interface (with Crossover Adapter) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Figure 115 - Ethernet Point-to-Point Layout
96
Page 107
TYPICAL LAYOUTS
6
When using a Local Area Network (LAN), one or more Matrix 400 XXX-010s can be connected to the network by using CAB-ETH-M0x straight through cables:
CAB-MSxx
CAB-ETH-M0x
Matrix 400™
3
CBX 2
Power 1
HOST NETWORK
Ethernet Interface (Straight Through Cables) Auxiliary Serial Interface (Local Echo) (RS232) External Trigger (for One Shot or Phase Mode)
Figure 116 - Ethernet Network Layout
97
Page 108
MATRIX 400™ REFERENCE MANUAL
7
7 READING FEATURES 7.1 OPTICAL ACCESSORY SELECTION Referring to Figure 117 and the formula below, use the data in the following table to calculate the FOV for your application. Viewing Angle Horizontal
Viewing Angle Vertical
Viewing Angle Diagonal
Min Focus Distance mm
Matrix 400 400-0x0 (SXGA)
LNS-1109 9 mm LNS-1112 12.5 mm LNS-1116 16 mm LNS-1125 25 mm LNS-1135 35 mm LNS-1150 50 mm
48.5° 37° 28.5° 18.5° 13° 9°
39.5° 30° 23° 15° 10,5° 7°
60° 46.5° 36° 23.5° 16.5° 11.5°
85 85 85 135 235 500
Matrix 400 600-0x0 (UXGA)
LNS-1006 6 mm LNS-1109 9 mm LNS-1112 12.5 mm LNS-1116 16 mm LNS-1125 25 mm LNS-1135 35 mm LNS-1150 50 mm
59.5° 40.5° 31° 24° 15° 11° 7.5°
46.5° 31° 23.5° 18° 11.5° 8.5° 5.5°
71° 49.5° 38° 30° 19° 13.5° 9.5°
85 85 85 85 135 235 500
Model
Lens
The viewing angle has a tolerance of 1° depending on the focus distance.
FOVx = 2 (d + 35 mm) tan (x/2) where: FOVx = horizontal, vertical or diagonal FOV x = horizontal, vertical or diagonal viewing angles. d = focus distance (from window surface to code surface)
35 mm d
FOV plane
Figure 117 – Reading Distance References
98
Page 109
READING FEATURES
7
Example: The FOV for a Matrix 400 600-0x0 base using the 16 mm lens at a focus distance of 200 mm is: FOVH = 2 [(200 mm + 35 mm) tan (24°/2)] = 100 mm FOVV = 2 [(200 mm + 35 mm) tan (18°/2)] = 74 mm
7.2 HORIZONTAL FOV VS. READING DISTANCE DIAGRAMS The following graphs represent the Horizontal Field of View (FOV) and Reading Distance based on the combination of a certain sensor (Matrix 400™ base model) and a certain lens. Each point represents the maximum achievable Field of View with the selected code resolution (in this point DOF is limited). The following diagrams are given for typical performance at 25°C using high quality grade A symbols according to ISO/IEC 15416 (1D code) and ISO/IEC 15415 (2D code) print quality test specifications. Testing should be performed with actual application codes in order to maximize the application performance.
NOTE
7.2.1
How to Use the Diagrams
40 0.50
For a given code resolution, the blue line represents the maximum Horizontal FOV. The reading distance can be selected by changing the lens.
35
Horizontal FOV (cm)
30
25
0.50
0.38
0.38
0.38
0.33
0.33
0.30
0.50
0.33
0.30
0.30
20 0.25
15
0.25
0.20
0.20
0.15
10
0.25
0.15
0.20 0.15
Each point represents the maximum FOV for a given code resolution. You can read this resolution code with the same lens at shorter distances but sacrificing FOV.
0.10
0.10
5
For a given Reading Distance you must select the lens that is able to read your code resolution.
0 0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160 170 180 190 200 210 220 230
Reading Distance (cm) SXGA - 25 mm
SXGA - 35 mm
SXGA - 50 mm
99
Page 110
MATRIX 400™ REFERENCE MANUAL
7
7.2.2
1D (Linear) Codes 1D Codes – Matrix 400 400-0x0 (SXGA) 9 mm, 12.5 mm, 16 mm
40 0.50
0.50
0.50
35
Horizontal FOV (cm)
30 0.38
25
0.38
0.33
0.38
0.33
0.30
0.33
0.30
0.30
20 0.25
15
0.25
0.20
0.20 0.15
0.15
10
0.12
Code Resolution Conversion
0.25
0.10 mm (4 mils) 0.12 mm (5 mils) 0.15 mm (6 mils) 0.20 mm (8 mils) 0.25 mm (10 mils) 0.30 mm (12 mils) 0.33 mm (13 mils) 0.38 mm (15 mils) 0.50 mm (20 mils)
0.20
0.15
0.12 0.10
5
0 0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Reading Distance (cm) SXGA - 9 mm
SXGA - 12.5 mm
SXGA - 16 mm
1D Codes – Matrix 400 400-0x0 (SXGA) 25 mm, 35 mm, 50 mm 40 0.50
0.50
0.50
35
Horizontal FOV (cm)
30 0.38
25
0.38
0.38
0.33
0.33
0.30
0.33
0.30
0.30
20 0.25
15
0.25
0.20
0.20
0.15
10
0.15
Code Resolution Conversion
0.25
0.10 mm (4 mils) 0.12 mm (5 mils) 0.15 mm (6 mils) 0.20 mm (8 mils) 0.25 mm (10 mils) 0.30 mm (12 mils) 0.33 mm (13 mils) 0.38 mm (15 mils) 0.50 mm (20 mils)
0.20 0.15
0.10
0.10
5
0 0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160 170 180 190 200 210 220 230
Reading Distance (cm) SXGA - 25 mm
100
SXGA - 35 mm
SXGA - 50 mm