Page 21

RAPID CONFIGURATION

1

STEP 7 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several important advantages:

Setup Wizard for rapid configuration and new users;

Defined configuration directly stored in the reader;

Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored.

To install VisiSet™, turn on the PC that will be used for the configuration, running Windows 98, 2000/NT, XP or Vista, then insert the VisiSet™ CD-ROM, wait for the CD to autorun and follow the installation procedure. This configuration procedure assumes a laptop computer, running VisiSet™, is connected to the reader's auxiliary port. After installing and running the VisiSet™ software program the following window:

Figure 15 - VisiSet™ Opening Window

11

Page 22

MATRIX 400™ REFERENCE MANUAL

1

Set the communication parameters from the "Options" menu. Then select "Connect", the following window appears:

Figure 16 - VisiSet™ Main Window After Connection

STEP 8 – CONFIGURATION USING SETUP WIZARD The Setup Wizard option is advised for rapid configuration or for new users. It allows reader configuration in a few easy steps. 1. Select the Setup Wizard button from the Main menu.

12

Page 23

RAPID CONFIGURATION

1

2. Remove the lens cover in order to focus the reader and loosen the two Locking Knobs on the lens. Adjust the Focus ring to the "Far position" and the Diaphragm ring to the "F4" 3 number setting which is the preferred setting for installation. Place the Grade A Barcode Test Chart in front of the reader at the correct reading distance (see step 3 and the Optical Accessory Selection table in the par. 7.1).

3. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the view image window. Select the largest code from the chart that completely fits into the view image window. Move the reader (or code) to center it. The code must be aligned across the X-axis reference line at the center of the FOV. See figure below. Press the Positioning button again to stop positioning.

3

3

For far reading distances, the Diaphragm ring can be set to values between F2 and F4 to increase image lighting.

13

Page 24

MATRIX 400™ REFERENCE MANUAL

1

4. Select a Calibration Mode choice and press the "Calibrate" button. The reader flashes once acquiring the image and auto determines the best exposure and gain settings. If the code symbology is enabled by default, the code will also be decoded.

4 5

5. Press the "Fine Focusing" button to activate the Fine Focusing Tool. The reader continuously acquires images and gives visual feedback on the focusing quality in the Focusing Tool window.

Rotate the Focusing ring on the lens. The Current Focus Quality Bar (green) together with the vertical optimal focus line (green) increase together until the optimal focus is reached; the vertical optimal focus line stops.

14

Page 25

RAPID CONFIGURATION

1

Continue rotating the Focusing ring on the lens a little farther; the Current Focus Quality Bar decreases (red) see below.

Rotate the Focusing ring in the opposite direction. The Current Focus Quality Bar (green) increases towards the vertical optimal focus line (green) until the optimal focus is reached; the Current Focus Quality Bar touches the vertical optimal focus line (indicating the best focus).

Tighten the Locking Knobs on the lens and press the "Close" button to return to the Setup Wizard.

15

Page 26

MATRIX 400™ REFERENCE MANUAL

1

6. Select a Code Setting Mode choice and press the "Code Setting" button. Using the Grade A Barcode Test Chart, this step performs image density calibration in order for Matrix 400™ to function correctly and to the fullest extent of its capabilities. The Setup Result section of the Setup Wizard window shows the code type results and the image density calibration settings.

6

7. Place the application specific code in front of the reader at the same reading distance and repeat steps 3, 4, and 6.

3 4

6

Setup Result

16

Page 27

RAPID CONFIGURATION

1

8. Select a Saving Options choice and press the "Save" button.

9. Close the Setup Wizard.

NOTE

If your application has been configured using the VisiSet™ Setup Wizard, your reader is ready. If necessary you can use VisiSet™ for advanced reader configuration.

17

Page 28

MATRIX 400™ REFERENCE MANUAL

1

STEP 9 – TEST MODE Use a code suitable to your application to test the reading performance of the system. 1. Enter the Test function by pressing and holding the X-PRESS™ push button until the Test LED is on. 2. Release the button to enter the Test function. Once entered, the Bar Graph on the five LEDs is activated and if the reader starts reading codes the Bar-Graph shows the Good Read Rate. In case of no read condition, only the STATUS LED is on and blinks. READY green

LEARN

GOOD green

SETUP

TRIGGER yellow

FOCUS

COM yellow

TEST

STATUS red Figure 17 – X-PRESS™ Interface: Test Function

3. To exit the Test, press the X-PRESS™ push button once.

By default, the Test exits automatically after three minutes. NOTE

The Bar Graph has the following meaning: READY

95%

LEARN

GOOD

75%

SETUP

TRIGGER

60%

FOCUS

COM

40%

TEST

STATUS

20%

18

Page 29

RAPID CONFIGURATION

1

ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the VisiSet™ Help On-Line. The following are alternative or advanced reader configuration methods:

Advanced Configuration Using VisiSet™ Advanced configuration can be performed through the VisiSet™ program by selecting Device> Get Configuration From Temporary Memory to open the Parameter Setup window in off-line mode. Advanced configuration is addressed to expert users being able to complete a detailed reader configuration. The desired parameters can be defined in the various folders of the Parameter Setup window and then sent to the reader memory (either Temporary or Permanent):

Figure 18 - VisiSet™ Parameter Setup Window

Host Mode Programming The reader can also be configured from a host computer using the Host Mode programming procedure, by commands via the serial interface. See the Host Mode Programming file on the CD-ROM.

Alternative Layouts If you need to install an Ethernet network, ID-NET™ network, Fieldbus network, PassThrough network, Multiplexer network or an RS232 Master/Slave refer to the Matrix 400™ Reference Manual. The reader can also be setup for alternative layouts by reading programming barcodes. See the "Setup Procedure Using Programming Barcodes" printable from the CD-ROM.

Code Quality Verification Matrix 400™ can be used as a Code Quality Verifier according to the ISO/IEC 15415, ISO/IEC 15416, AS9132, and AIM DPM Standards. For more details see the Matrix 400™ Code Quality Verifier Solution manual on the CD-ROM. 19

Page 30

2

MATRIX 400™ REFERENCE MANUAL

2 INTRODUCTION 2.1 PRODUCT DESCRIPTION Matrix 400™ is a Datalogic industrial compact 2D imager designed and produced to be a high performance affordable solution for both linear and two-dimensional code reading applications. Matrix 400™ uses imaging technology and provides complete reading system functions by integrating image capturing, decoding and communicating in a single compact and versatile product. Matrix 400™ sets a new standard in 2D imager technology offering high performance with improved reading flexibility thanks to its intrinsic modularity. Matrix 400™ features excellent reading and verifying performance thanks to 1.3 and 2.0 Mega pixel sensors and smart proprietary decoding libraries. The modular combination of Mega pixels sensors, powerful lighting and adjustable C-Mount lenses provide high flexibility in covering application with various requirements. Innovative X-PRESS™ interface, combined with Blue Diamonds™ aiming and focusing system and a Good Read Spot, enhance the ease of setup and use. Rugged construction, IP67 protection and max 50°C operative temperature make the Matrix 400™ the ideal product for industrial applications. Matrix 400™ has been developed for use in numerous industries like: Automotive DPM (Direct Part Marked) Reading and Verification Tires Sorting Electronics Large PCB Board Tracking Electronics Product Tracking Distribution & Retail Industry Presentation Scanner Small Objects Tracking & Sorting Warehouse applications Medical & Pharmaceutical Medical Devices Traceability Pharmaceutical and Medicine Manufacturing Chemical & Biomedical Analysis Food & Beverage Work in Progress Traceability Code Quality Control This technology intrinsically provides omni-directional reading.