The text of a manual · part 4 of 15
Matrix 400 Reference Manual, pages 31 to 40
Pages 31 to 40 of 147
The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic Matrix-400
Page 31
INTRODUCTION
2
Standard Application Program A Standard Application Program is factory-loaded onto Matrix 400™. This program controls code reading, data formatting, serial port and Ethernet interfacing, and many other operating and control parameters. It is completely user configurable from a Laptop or PC using the dedicated configuration software program VisiSet™, provided on CD-ROM with the reader. There are different programmable operating modes to suit various code reading system requirements. Quick, automatic focus, positioning, calibration and code setting of the imager can be accomplished using the X-PRESS™ button and LEDs on top of the reader without the necessity of a PC. The previous functions can also be performed through VisiSet™ through the Setup Wizard. This tool includes visual feedback from the reader. VisiSet™ provides a Calibration Tool to verify the exact positioning of the reader and to maximize its reading performance. Statistics on the reading performance can also be visualized through a dedicated window in VisiSet™. Symbol Verification can be performed through VisiSet™ when the reader has been installed and setup as a Verifier station. For details see the Matrix Code Quality Verifier Solution manual. Programmability If your requirements are not met by the Standard Application Program, Custom Application Programs can be requested at your local Datalogic distributor. Some of the main features of this reader are given below: Excellent Performance 1.3 MPixels (SXGA) & 2.0 MPixels (UXGA) models Adjustable focus through C-Mount lenses Powerful Internal Lighting Systems Outstanding decoding capability on 1D, 2D, Stacked, Postal symbologies Excellent performance on DPM applications Omni-directional reading Frame Rate up to 27 frames/sec for SXGA models and 15 frame/sec for UXGA models Region Of Interest Windowing for higher frame rate Up to 100 readable codes in a single frame
21
Page 32
2
MATRIX 400™ REFERENCE MANUAL
Ease of Setup Quick installation without PC by using X-PRESS™ interface for easy and intuitive setup Blue Diamonds™ aiming and focusing system Automatic Imager calibration and Code Settings Calibration Tool to verify exact code positioning in the Field of View and to maximize the reading performance Windows-based VisiSet™ software to configure the reader parameters via PC serial or Ethernet interface User-defined database of Image Acquisition Settings (parameter sets) Smart Fast Bracket Ease of Use X-PRESS™ interface LEDs provide operational and performance feedback Green Spot and beeper for immediate Good Read feedback Different operating modes to suit various application requirements Multi Image Acquisition Settings for higher reader flexibility Run Time Self-Tuning for extreme reader flexibility Image saving and storage with buffering capability Diagnostic software tools Flexible Solution Modular design Adjustable C-Mount lenses Complete set of Accessories like external lighting systems, light filters, mounting brackets, connection boxes, cables and photocells Ethernet Connectivity with TCP/IP socket for reader parameter configuration, data and image transfer, HTTP server, FTP and mail client, etc. 3 serial communication interfaces (Main, Auxiliary, ID-NET™) General purpose optocoupled I/Os Versatility Excellent reading performance on Direct Part Marked (DPM) symbols Code Quality Verification according to ISO/IEC 16022, ISO/IEC 18004, ISO/IEC 15415, ISO/IEC 15416 and AS9132 and AIM DPM standards. Match Code option with a user-defined match code database
22
Page 33
INTRODUCTION
2
Industrial Strength Industrial compact 2D reader Rugged full metal construction Sealed circular connectors IP67 protection class 50 °C max operating temperature Supply voltage ranges from 10 to 30 Vdc The reader is particularly suitable for industrial environments where protection against harsh external conditions is required. The reader is contained in an aluminum housing; with its internal illuminator, C-Mount lens and protective cover, the mechanical dimensions are 123 x 60.5 x 87 mm and it weighs about 482 g. Electrical connection of Power, Host interfaces and I/O signals is provided through an M16 (IP67) 19-pin connector (Figure A, 9). A standard M12 D-Coded (IP67) Ethernet connector is present on Matrix 400 XXX-X1X models (Figure A, 10).
23
Page 34
MATRIX 400™ REFERENCE MANUAL
2
2.2 INDICATORS AND KEYPAD BUTTON 3 4 5 6 7 1
2
8
Figure 19 - Indicators
The following LED indicators are located on the reader: NET PWR yellow LED indicates connection to the on-board Ethernet network (for Ethernet models) (Figure 19, 1) blue LED indicates that the reader is connected to the power supply (Figure 19, 2)
In normal operating mode the colors and meaning of the five LEDs are illustrated in the following table: READY GOOD TRIGGER COM STATUS green LED indicates that the reader is ready to operate (Figure 19, 3) green LED confirms successful reading (Figure 19, 4) yellow LED indicates the status of the reading phase (Figure 19, 5) yellow LED indicates active communication on the main serial port * (Figure 19, 6) red LED indicates a NO READ result (Figure 19, 7)
* When connected to a Fieldbus network through the CBX500, the COM LED is always active, even in the absence of data transmission, because of polling activity on the Fieldbus network.
During the reader startup (reset or restart phase), these five LEDs blink for one second. In X-PRESS™ Configuration mode the colors and meaning of these five LEDs are described in par. 2.4. The keypad button (Figure 19, 8), is software programmable. By default it starts the XPRESS™ interface for quick installation without using a PC (see chp. 1).
24
Page 35
INTRODUCTION
2
2.3 ID-NET™ The ID-NET™ network is a built-in high-speed interface dedicated for high-speed reader interconnection. ID-NET™ is in addition to the Main and Auxiliary serial interfaces. The following network configurations are available:
ID-NET™ M/S Synchronized: Single station – multiple readers
ID-NET™ interface allows local connection of multiple readers reading different sides of the same target. All readers share a single presence sensor and activate/deactivate simultaneously. At the end of each reading phase a single data message is transmitted to the host. Thanks to ID-NET™, data communication among readers is highly efficient so that an immediate result will be available.
25
Page 36
MATRIX 400™ REFERENCE MANUAL
2
ID-NET™ M/S Multidata: Multiple stations – single reader
ID-NET™ interface allows connection of readers reading objects placed on independent conveyors. All readers are typically located far away from each other and they use a dedicated presence sensor. At the end of each reading phase, each reader transmits its own data message to the host. Thanks to ID-NET™, data collection among readers is accomplished at a high speed without the need of an external multiplexing device. This leads to an overall cost reduction and to a simple system wiring.
2.3.1
How To Setup/Configure the Reader Network
A complete ID-NET™ reader network can be easily setup through VisiSet™ as follows: Mounting & Connection 1. Mechanically mount/install all the readers (refer to par. 3.2 and 3.3). 2. Wire ID-NET™ (refer to par. 4.3 or 5.5). 3. Power up the entire system. Configuration of Slaves 1. Connect a PC equipped with VisiSet™ to the Main, Auxiliary or Ethernet interface of the planned Slave reader. 2. Launch VisiSet™ and connect to the Slave reader. 3. From the VisiSet™ Device Menu select "Parameter Setup". 4. Set the Role of the Slave reader (Synchronized or Multidata) from Reading System Layout > Device Network Setting > Topology Role parameter.
the
5. Set the Slave Address according to the desired value 1-31 from the Reading System Layout > Device Network Setting > Slave Address parameter. Each reader must have a different Address on the ID-NET™ Network. 6. If necessary, set the ID-NET™ baudrate from the Reading System Layout > Device Network Setting > Network Baud Rate parameter, (500 kbs default). 26
Page 37
INTRODUCTION
2
7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data Collection parameters, etc.]. 8. If using the CBX connection box equipped with a BM100 Backup module, perform Device Backup at the Slave. The Slave device is now Configured. Repeat these steps for each Slave reader in the IDNET™ network. Configuration of Master 1. Connect a PC equipped with VisiSet™ to the Main, Auxiliary or Ethernet interface of the planned Master reader. 2. Launch VisiSet™ and connect to the Master reader. 3. From the VisiSet™ Device Menu select "Parameter Setup". 4. Set the Role of the Master reader (Synchronized or Multidata) from Reading System Layout > Device Network Setting > Topology Role parameter.
the
5. Enable the planned Slave device N from the Reading System Layout > Expected Slave Device #N > Status parameter and, if desired, set the related identification string from the Expected Slave Device #N > Device Description parameter. Repeat this step for all planned Slave devices. 6. If necessary, set the ID-NET™ baudrate from the Reading System Layout > Device Network Setting > Network Baud Rate parameter, (500 kbs default). 7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data Collection parameters, etc.]. 8. If using the CBX connection box equipped with a BM100 Backup module, perform Device Backup at the Master. 9. From the VisiSet™ Device Menu select "ID-NET™ Status Window" and click on the "Look For Devices On Network" button to check the status of the expected Slave devices within the ID-NET™ network.
The reader network is ready. 27
Page 38
MATRIX 400™ REFERENCE MANUAL
2
2.3.2
ID-NET™ Slave Management Through Master
When an ID-NET™ layout has already been configured, it is possible to modify the configuration of any Slave from VisiSet through the Master. 1. Connect a PC equipped with VisiSet™ to the Main, or Auxiliary interface of the Master reader. 2. Launch VisiSet™ and connect to the Master reader. 3. From the VisiSet™ Device Menu select "ID-NET™ Status Window" and click on the "Look For Devices On Network" button to check the status of the expected Slave devices within the ID-NET™ network. 4. Double click on the Get function of the specific slave in the Parameter column of the IDNET Status Window when its Current Status is "Present". The Parameter Setup window will be displayed after a time based on the network speed, with the configuration of the selected slave. 5. From the specific Slave Parameter Setup Window, change any parameter (not in interactive mode), save the configuration to a file, or load a configuration from a file. 6. Send the modified configuration to the slave.
CAUTION
28
If a wrong configuration is set or if the Slave Reading System Layout parameters are changed, the slave could lose the network connection.
Page 39
INTRODUCTION
2
2.4 X-PRESS™ HUMAN MACHINE INTERFACE X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. Status information is clearly presented by means of the five colored LEDs, whereas the single push button gives immediate access to the following relevant functions:
Learn to self-detect and auto-configure for reading unknown codes
Setup to perform Exposure Time and Gain calibration.
Focus/Locate to turn on the Blue Diamonds™ to aid focusing and positioning.
Test with bar graph visualization to check static reading performance
2.4.1
X-PRESS™ Functions
Quick access to the following functions is provided by an easy procedure using the push button:
READY green GOOD
1 – Press the button (the Status LED will give a visual feedback).
green
2 – Hold the button until the specific function LED is on (Test, Focus, Setup or Learn).
yellow
3 – Release the button to enter the specific function.
LEARN
SETUP
TRIGGER FOCUS
COM yellow
TEST
STATUS red
Once button is pressed, the cycle of LEDs activation is as follows: READY
READY green GOOD green green
TRIGGER yellow yellow
STATUS yellow
FOCUS
COM yellow
TEST
TEST
STATUS red
SETUP
TRIGGER
FOCUS
STATUS red
Release button to Exit green
COM TEST
LEARN
GOOD SETUP
TRIGGER
FOCUS
COM yellow green
LEARN
GOOD SETUP yellow
READY green
LEARN red
Release button to enter Test Mode
Release button to enter Focus/Locate Mode
29
Page 40
MATRIX 400™ REFERENCE MANUAL
2 READY
READY green GOOD green green
TRIGGER green
TRIGGER
COM yellow
STATUS
TRIGGER yellow
TEST
STATUS red red
Release button to enter Setup Mode
FOCUS
COM TEST
STATUS red
SETUP yellow
FOCUS
COM TEST
LEARN
GOOD SETUP yellow
FOCUS yellow green
LEARN
GOOD SETUP yellow
READY green
LEARN
Release button to enter Learn Mode
(cycle) Release button to Exit
Test Mode (Function 1) Once entered, the Bar Graph on the five LEDs is activated and if the imager starts reading codes the Bar-Graph shows the Good Read Rate. In case of a NO READ condition, only the Status LED is on and blinks. The Bar Graph has the following meaning: READY
95%
LEARN
GOOD
75%
SETUP
TRIGGER
60%
FOCUS
COM
40%
TEST
STATUS
20%
To exit the Test Mode, press the X-PRESS™ push button once.
By default, the Test exits automatically after three minutes. NOTE
Focus/Locate (Function 2) This function causes the Blue Diamonds™ to turn on. The Blue Diamonds™ can be used to focus the lens at the desired reading distance and since they are centered on the FOV they can also be used to position the imager on the code. The Focus LED blinks to indicate this state. To exit the Focus/Locate Mode, press the X-PRESS™ push button once. The Blue Diamonds™ turn off. 30