Manual · Datalogic
Matrix 400 Quick Reference Guide
Manual24 pagesPDF 3.3 MB
Quick reference guide for the Datalogic Matrix 400 fixed-mount 2D imager: assembly, wiring, mounting, focusing and setup.
Covers · 1 model
The models it covers
Summary
What is in it
A step-by-step quick reference guide for installing the Datalogic Matrix 400 fixed-mount imager in a stand-alone layout. It covers assembling the lens and illuminator, connecting through the CBX100/CBX500 or the 19-pin connector, mounting and positioning, focusing with the Blue Diamonds aid, calibrating image density, configuring with the X-PRESS interface or the VisiSet Setup Wizard, and test mode. An appendix gives optical accessory selection, technical features and mechanical dimensions.
Its parts
- Step 1: Assemble the Reader
- Step 2: Connect the System
- Step 3: Mount and Position the Reader
- Step 4: Focus the Reader
- Step 5: Calibrate Image Density
- Step 6: X-PRESS Configuration
- Step 7: Installing VisiSet Configuration Program
- Step 8: Configuration Using Setup Wizard
- Step 9: Test Mode
- Advanced Reader Configuration
- Appendix
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Datalogic quick reference guide for the Matrix 400 imager reader in a stand-alone setup. It walks through assembling the lens and illuminator, wiring, mounting, focusing, calibration and configuration with the X-PRESS button or the VisiSet software, and lists lenses, viewing angles and technical features.
- What it is
- Imager reader that takes a separate C-Mount lens and an internal or external illuminator p. 3
- Interfaces
- Main RS232, RS485 full-duplex or RS485 half-duplex; auxiliary RS232; ID-NET; Ethernet on Ethernet models; 19-pin M16 connector p. 5, 20
- Power
- 10 to 30 Vdc, 8 W max., 5 W typical; UL Listed LPS or Class 2 supply rated minimum 1 A p. 20, 22
- Image format
- Matrix 400 400-0x0: SXGA (1280x1024); 400 600-0x0: UXGA (1600x1200) p. 19, 20
- Dimensions and weight
- 123 x 60.5 x 87 mm (4.85 x 2.38 x 3.43 in.) with lens cover; 482 g (17 oz.) with lens and internal illuminator; aluminium p. 20
- Protection class
- The manual states IP67 when connected to sealed IP67 cables with the lens cover mounted p. 20
- Lenses
- C-Mount: LNS-1006 6 mm (600-0x0 models only), LNS-1109 9 mm, LNS-1112 12.5 mm, LNS-1116 16 mm, LNS-1125 25 mm, LNS-1135 35 mm, LNS-1150 50 mm p. 3, 19
- Internal illuminators
- LT-001, LT-002, LT-003, LT-004 and LT-006, in red or white, wide, narrow or super narrow angle p. 3
- Connection boxes
- CBX100 and CBX500 terminal pinouts given; stand-alone layout shows a CAB-MS01 cable p. 4
- 2-D codes
- Data Matrix ECC 200 and QR Code (standard and direct marking), MAXICODE, Aztec Code, Microglyph (needs an activation procedure) p. 20
- 1-D and stacked codes
- PDF417 and Micro PDF417, Code 128 (EAN 128), Code 39, Interleaved 2 of 5, Codabar, Code 93, Pharmacode, EAN-8/13, UPC-A/E, GS1 DataBar (RSS), Composite p. 20
- Postal codes
- Australia Post, Royal Mail 4 State Customer, Kix Code, Japan Post, PLANET, POSTNET, POSTNET (+BB), Intelligent Mail p. 20
- Modes and setup
- ONE SHOT, CONTINUOUS and PHASE MODE; set up with the X-PRESS button, VisiSet over serial or Ethernet, or serial Host Mode commands; settings kept in Flash p. 20
- Code quality verification
- Can work as a code quality verifier to ISO/IEC 15415, ISO/IEC 15416, AS9132 and AIM DPM p. 17
What this manual walks you through
- Assembling the lens and internal illuminator p. 3
- Wiring a stand-alone layout and the connector pinouts p. 4, 5
- Mounting and angling the reader p. 6
- Focusing with the Blue Diamonds p. 7
- Calibrating image density with the test chart p. 8
- Configuring code reading with the X-PRESS button p. 9
- Installing VisiSet and using its Setup Wizard p. 10, 11, 12, 13, 14, 15
- Testing read performance with the bar graph p. 16
- Calculating the field of view for each lens p. 19
- The X-PRESS LEDs and their meaning p. 18
Good to know
- Disconnect the reader from the power supply while assembling the lens and illuminator. p. 3
- Do not touch the sensor aperture, lens glass or lens cover glass. p. 3
- Do not tie GND, SGND and REF to different external grounds; drops over 0.8 Vdc can damage the internal filtering. p. 4
- Repeat image density calibration on first installation and whenever the lens or focal distance changes. p. 8
- In high ambient temperatures, use a metal mounting bracket for heat dissipation. p. 20
Questions this manual answers
What power supply does the Datalogic Matrix 400 need?
10 to 30 Vdc from a UL Listed LPS or Class 2 power unit rated at least 1 A; it draws up to 8 W. p. 20, 22
Which lenses fit the Matrix 400?
C-Mount lenses from 6 mm to 50 mm (LNS-1006 to LNS-1150); the 6 mm lens is only for Matrix 400 600-0x0 models. p. 3, 19
How do I focus the Matrix 400?
Hold the X-PRESS button to enter the Focus function, turn the focus ring until the Blue Diamonds are sharp, then tighten the locking knobs. p. 7
What software configures the Matrix 400?
VisiSet, installed from CD-ROM on a PC running Windows 98, 2000/NT, XP or Vista and connected to the reader's auxiliary port. p. 10
How long does the Matrix 400 test mode run?
By default it exits automatically after three minutes; pressing the X-PRESS button once leaves it sooner. p. 16