Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 3

Matrix 400 Quick Reference Guide, pages 1 to 8

Pages 1 to 8 of 24

The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic Matrix-400

Page 1

Matrix 400™ QUICK REFERENCE GUIDE 1

3

2

4

5

2

7

10

2

8

9

6 Figure A

1

Device Class Label

6

HMI X-PRESS™ Interface

2

Mounting Holes (12)

7

"POWER ON" LED

3

Lens Cover

8

Power - Serial Interfaces - I/O Connector

4

Lens (separate accessory)

9

Ethernet Connector (Ethernet Models Only)

5

Internal Illuminator (separate accessory)

10 Ethernet Connection LED (Ethernet Models Only)

NOTE

This manual illustrates a Stand Alone application. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc. and for a complete reader configuration using the VisiSet™ configuration program, refer to the Matrix 400™ Reference Manual available on the CD. This manual is also downloadable from the Web at www.automation.datalogic.com/matrix400.

Page 2

MATRIX 400™ QUICK GUIDE

UPDATES AND LANGUAGE AVAILABILITY

UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com

I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a: www.automation.datalogic.com

F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.automation.datalogic.com

D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Adresse : www.automation.datalogic.com

E En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. Dirección Internet : www.automation.datalogic.com

SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information including:

•

PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - VisiSet™ a utility program, which allows device configuration using a PC. It provides RS232 and Ethernet interface configuration.

•

SERVICES & SUPPORT - Datalogic Services - Warranty Extensions and Maintenance Agreements - Authorised Repair Centres

•

CONTACT US E-mail form and listing of Datalogic Subsidiaries

2

Page 3

MATRIX 400™ QUICK GUIDE

STEP 1 – ASSEMBLE THE READER The first step to perform is to assemble the accessories that make up the Matrix 400™ reader. The lens and either an internal or an external illuminator must be used. This procedure shows an internal illuminator.

Matrix 400™ must be disconnected from the power supply during this procedure. CAUTION 1.

In a dust-free environment, remove the Matrix 400™ Lens Cover by unscrewing it.

Do not touch the sensor aperture, lens glass or lens cover glass. These areas must be kept clean. Avoid any abrasive substances that might damage these surfaces during cleaning. CAUTION 2.

Remove the sensor protection label by pulling it off of the base.

3.

Mount the lens by screwing it tightly onto the base.

4.

If using an internal illuminator:

5.

a.

Mount the 4 internal illuminator spacers into the holes provided on the base.

b.

Align and mount the Illuminator board tightly onto the spacers using the 4 screws provided in the illuminator package. The spacers are positioned asymmetrically to avoid incorrect alignment.

To keep dust and dirt off of the lens during mounting, temporarily replace the lens cover. Locking Knobs

Internal Illuminator Lens Cover

Illuminator Spacers Figure 1 – Assembling Matrix 400™ Accessories

REQUIRED ACCESSORIES The following table shows the correct lens/illuminator combinations to be used for Matrix 400™ imager assembly. Lenses 93ACC1793

LNS-1006

93ACC1794

LNS-1109

6 mm C-Mount Lens (only for Matrix 400 600-0x0 models) 9 mm C-Mount Lens

93ACC1795

LNS-1112

12.5 mm C-Mount Lens

93ACC1796

LNS-1116

16 mm C-Mount Lens

93ACC1797

LNS-1125

25 mm C-Mount Lens

93ACC1798 93ACC1799

LNS-1135 LNS-1150

35 mm C-Mount Lens 50 mm C-Mount Lens

Internal Illuminators 93A401020 93A401022 93A401020 93A401022 93A401020 93A401022 93A401019 93A401021 93A401019 93A401021 93A401024 93A401024

LT-002 LT-004 LT-002 LT-004 LT-002 LT-004 LT-001 LT-003 LT-001 LT-003 LT-006 LT-006

Red Wide Angle White Wide Angle Red Wide Angle White Wide Angle Red Wide Angle White Wide Angle Red Narrow Angle White Narrow Angle Red Narrow Angle White Narrow Angle Red Super Narrow Angle Red Super Narrow Angle

3

Page 4

MATRIX 400™ QUICK GUIDE

STEP 2 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 2. In this layout the data is transmitted to the Host on the main serial interface. Data can also be transmitted on the RS232 auxiliary interface independently from the main interface selection. When One Shot or Phase Mode Operating mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. PG 6000

CBX Main Interface

CAB-MS01

Matrix 400™ Host

P.S.*

I/O, AUX

* External Trigger or Presence Sensor (for One Shot or Phase Mode)

Figure 2 – Matrix 400™ in Stand Alone Layout

CBX100/CBX500 Pinout for Matrix 400™ The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the Matrix 400™ reader is connected by means of the CBX100/CBX500: CBX100/500 Terminal Block Connectors Vdc GND Earth

+V I1A I1B -V +V I2A I2B -V Shield

Power Power Supply Input Voltage + Power Supply Input Voltage Protection Earth Ground

+V -V O1+ O1O2+ O2-

Inputs Power Source – External Trigger External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) TX Power Reference – External Trigger RX Power Source – Inputs SGND Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) REF Power Reference – Inputs ID+ Shield IDNetwork Cable Shield Main Interface RS232 RS485 Full-Duplex TX TX+ RTS TX*RX+ RX *RXCTS SGND SGND

Outputs Power Source - Outputs Power Reference - Outputs Output 1 + Output 1 Output 2 + Output 2 Auxiliary Interface Auxiliary Interface TX Auxiliary Interface RX Auxiliary Interface Reference ID-NET™ Network Reference ID-NET™ network + ID-NET™ network -

RS485 Half-Duplex RTX+ RTX-

SGND

* Do not leave floating, see Reference Manual for connection details.

CAUTION

4

Do not connect GND, SGND and REF to different (external) ground references. GND, SGND and REF are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.

Page 5

MATRIX 400™ QUICK GUIDE

19-pin Connector Pinout for Matrix 400™ The table below gives the pinout of the 19-pin M16 male connector for connection to the power supply and input/output signals. Use this pinout when the Matrix 400™ reader is connected by means of the 19-pin connector:

Figure 3 - 19-pin M16 Male Connector

19-pin M16 male connector pinout Pin

Name

Function

A L K B C D E H F G I S O R P

Vdc GND CHASSIS I1A I1B I2A I2B O1+ O1O2+ O2RX TX ID+ ID-

Power supply input voltage + Power supply input voltage Cable shield internally connected by capacitor to the chassis External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) Output 1 + Output 1 Output 2 + Output 2 Auxiliary RS232 RX Auxiliary RS232 TX ID-NET™ network + ID-NET™ network RS485 RS485 RS232 Full-Duplex Half-Duplex TX TX+ RTX+ *RX+ RX RTS TXRTX*RXCTS

Pin

Name

M U N T

MAIN INTERFACE (SW SELECTABLE)

* Do not leave floating, see Reference Manual for connection details.

5

Page 6

MATRIX 400™ QUICK GUIDE

STEP 3 – MOUNT AND POSITION THE READER 1.

To mount the Matrix 400™, use the mounting brackets to obtain the most suitable position for the reader. Two of the most common mounting configurations are shown in the figures below. Other mounting solutions are provided in the Matrix 400™ Reference Manual.

Pitch

Tilt

Figure 4 –Positioning with Mounting Bracket (Back)

Pitch

Skew Figure 5 –Positioning with Mounting Bracket (Side)

2.

When mounting the Matrix 400™ take into consideration these three ideal label position angles: Pitch or Skew 10° to 20° and Tilt 0°, although the reader can read a code at any tilt angle. P

T

S

Minimize

Assure at least 10°

Minimize

Figure 6 – Pitch, Skew and Tilt Angles

3.

Refer to the Optical Accessory Selection table in the Appendix of this Quick Reference Guide for FOV calculation and minimum distance requirements according to the base/lens combination used for your application.

NOTE

6

Rapid Configuration of the Matrix 400™ reader can be made either through the X-PRESS™ interface (steps 4-6) which requires no PC connection, or by using the VisiSet™ Setup Wizard (steps 7-8). Select the procedure according to your needs.

Page 7

MATRIX 400™ QUICK GUIDE

STEP 4 – FOCUS THE READER Matrix 400™ provides a built-in tool called Blue Diamonds™ to aid focusing the reader. The Blue Diamonds™ are accessed through the X-PRESS™ Interface. 1.

Remove the lens cover in order to focus the reader.

2.

Prepare the correct accessory lens for your application: a.

Loosen the two Locking Knobs on the lens.

b.

Adjust the Focus ring to the "Far position" and the Diaphragm ring to the "F4" number setting which is the preferred setting for installation.

1

3.

Power the reader on. During the reader startup (reset or restart phase), all the LEDs blink for one second. On the connector side of the reader near the cable, the “POWER ON” LED (blue) indicates the reader is correctly powered.

4.

Enter the Focus function by pressing and holding the X-PRESS™ push button until the Focus LED is on.

5.

Release the button to enter the Focus function. The Blue Diamonds™ turn on.

The procedure is as follows: a.

b.

READY

Adjust the Focus ring towards the "Near position" until the Blue Diamonds™ are perfectly in focus, see Figure 8.

green

At long focal distances a "skew" angle may cause a noticeable difference in focus between the two diamonds, in this case select the best possible focus (both diamonds slightly out of focus). Tighten the Focus Locking Knob.

green

Tighten the Diaphragm Locking Knob.

yellow

LEARN

GOOD SETUP

TRIGGER yellow

FOCUS

COM TEST

STATUS red

Figure 7 – X-PRESS™ Interface: Focus Function

If necessary you can use the Fine Focusing Tool in the VisiSet™ Setup Wizard for fine focusing. See Step 8. NOTE

FOV

Blue Diamond™ in focus

Figure 8 – Focus Function Using Blue Diamonds™

6.

Exit the Focus function by pressing the X-PRESS™ push button once. The Blue Diamonds™ turn off.

7.

Replace the lens cover, screwing it tightly to the base.

1

For far reading distances, the Diaphragm ring can be set to values between F2 and F4 to increase image lighting and Blue Diamond™ visibility.

7

Page 8

MATRIX 400™ QUICK GUIDE

STEP 5 – CALIBRATE IMAGE DENSITY In order to function correctly to the fullest extent of its capabilities, Matrix 400™ must acquire information regarding image density or PPI (pixels per inch). This calibration takes place through the X-PRESS™ Interface and the Grade A Barcode Test Chart included in the package. This procedure is necessary for the first time installation, if the lens type is changed or if the focal distance is changed.

LOCATE 1. Enter the Focus function by pressing and holding the X-PRESS™ push button until the Focus LED is on. 2. Release the button to enter the Focus function. The Blue Diamonds™ turn on. 3. From the Grade A Barcode Test Chart, select the longest code whose length fits between the two Blue Diamonds™. Rotate the code 90 degrees and position the code at the center of the FOV (equidistant from the Blue Diamonds™).

READY green

LEARN

GOOD green

SETUP

TRIGGER yellow

FOCUS

COM yellow

TEST

STATUS red

Figure 9 – X-PRESS™ Interface: Locate Function

4. Exit the Focus function by pressing the X-PRESS™ push button once. The Blue Diamonds™ turn off.

SETUP 5. Enter the Setup function by pressing and holding the X-PRESS™ push button until the Setup LED is on. 6. Release the button to enter the Setup function. The Setup LED will blink until the procedure is completed. The Setup procedure ends when the Image Acquisition parameters are successfully saved in the reader memory, the Setup LED will remain on continuously and Matrix 400™ emits 3 high pitched beeps. If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 400™ will exit without saving the parameters to memory, the Setup LED will not remain on continuously but it will just stop blinking. In this case Matrix 400™ emits a long low pitched beep. 7. Exit the Setup function by pressing the X-PRESS™ push button once.

READY green

LEARN

GOOD green

SETUP

TRIGGER yellow

FOCUS

COM yellow

TEST

STATUS red

Figure 10 – X-PRESS™ Interface: Setup Function

LEARN 8. Enter the Learn function by pressing and holding the X-PRESS™ push button until the Learn LED is on. 9. Release the button to enter the Learn function. The Learn LED will blink until the procedure is completed. The Learn procedure ends when the Image Density value is successfully saved in the reader memory, the Learn LED will remain on continuously, the Green Spot is activated and Matrix 400™ emits 3 high pitched beeps. If the calibration cannot be reached after a timeout of about 3 (three) minutes Matrix 400™ will exit without saving the parameters to memory, the Learn LED will not remain on continuously but it will just stop blinking. In this case Matrix 400™ emits a long low pitched beep. 10. Exit the Setup function by pressing the X-PRESS™ push button once.

8

READY green

LEARN

GOOD green

SETUP

TRIGGER yellow

FOCUS

COM yellow

TEST

STATUS red

Figure 11 – X-PRESS™ Interface: Learn Function