Page 299

Code 93 Enable

Code 93 AIM ID This feature enables/disables transmission of the Code 93 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

CODE 93 AIM ID = DISABLE

CODE 93 AIM ID = ENABLE

Product Reference Guide

5-251

Page 300

Programming

Code 93 Label ID This feature specifies a Code 93 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 93 LABEL ID

5-252

®

Magellan

2200VS and 2300HS

Page 301

Code 93 Enable

Code 93 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 93. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

NOTE

If variable-length control was selected, you must now set the features Code 93 Maximum Label Length and Code 93 Minimum Label Length. If fixed-length control was selected, you must now set Code 93 Fixed Length 1 and Code 93 Fixed Length 2.

CODE 93 LENGTH CONTROL = VARIABLE-LENGTH

CODE 93 LENGTH CONTROL = FIXED-LENGTH

Product Reference Guide

5-253

Page 302

Programming

Code 93 Maximum Label Length This feature specifies the maximum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding. NOTE

Maximum label length should be greater than or equal to minimum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 93 MAXIMUM LABEL LENGTH

5-254

®

Magellan

2200VS and 2300HS

Page 303

Code 93 Enable

Code 93 Minimum Label Length This feature specifies the minimum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variablelength decoding. NOTE

Minimum label length should be less than or equal to maximum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 93 MINIMUM LABEL LENGTH Product Reference Guide

5-255

Page 304

Programming

Code 93 Fixed Length 1 This feature specifies Code 93 first fixed length. This applies when Code 93 Length Control is set to fixedlength decoding. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 93 FIXED LENGTH 1

5-256

®

Magellan

2200VS and 2300HS

Page 305

Code 93 Enable

Code 93 Fixed Length 2 This feature specifies Code 93 second fixed length. This applies when Code 93 Length Control is set to fixed-length decoding. NOTE

If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 00, or 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 93 FIXED LENGTH 2

Product Reference Guide

5-257

Page 306

Programming

Code 93 Stitching Enables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.

CODE 93 STITCHING = DISABLE

CODE 93 STITCHING = ENABLE

5-258

®

Magellan

2200VS and 2300HS

Page 307

MSI/Plessey Enable

MSI/Plessey Enable Enables/disables the ability of the scanner to decode MSI/Plessey labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

MSI/PLESSEY = DISABLE

MSI/PLESSEY = ENABLE

Product Reference Guide

5-259

Page 308

Programming

MSI/Plessey Check Character Calculation Enables/disables calculation and verification of optional MSI/Plessey check characters. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

MSI/PLESSEY CHECK CHARACTER CALCULATION = DISABLE

MSI/PLESSEY CHECK CHARACTER CALCULATION = ENABLE

5-260

®

Magellan