Page 289

Codabar Enable

Codabar Check Character Transmission Enables/disables transmission of an optional Codabar check character. Applies only when Codabar Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

CODABAR CHECK CHARACTER TRANSMISSION = DISABLE

CODABAR CHECK CHARACTER TRANSMISSION = ENABLE

Product Reference Guide

5-241

Page 290

Programming

Codabar AIM ID This feature enables/disables transmission of the Codabar AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

CODABAR AIM ID = DISABLE

CODABAR AIM ID = ENABLE

5-242

®

Magellan

2200VS and 2300HS

Page 291

Codabar Enable

Codabar Label ID This feature specifies a Codabar label ID to e added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODABAR LABEL ID

Product Reference Guide

5-243

Page 292

Programming

Codabar Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Codabar. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

NOTE

If variable-length control was selected, you must now set the features Codabar Maximum Label Length and Codabar Minimum Label Length. If fixed-length control was selected, you must now set Codabar Fixed Length 1 and Codabar Fixed Length 2.

CODABAR LENGTH CONTROL = VARIABLE-LENGTH

CODABAR LENGTH CONTROL = FIXED-LENGTH

5-244

®

Magellan

2200VS and 2300HS

Page 293

Codabar Enable

Codabar Maximum Label Length This feature specifies the maximum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE

Maximum label length should be greater than or equal to minimum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 03 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (03-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODABAR MAXIMUM LABEL LENGTH Product Reference Guide

5-245

Page 294

Programming

Codabar Minimum Label Length This feature specifies the minimum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE

Minimum label length should be less than or equal to maximum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 03 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (03-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODABAR MINIMUM LABEL LENGTH

5-246

®

Magellan

2200VS and 2300HS

Page 295

Codabar Enable

Codabar Fixed Length 1 This feature specifies Codabar first fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixed-length decoding. NOTE

Decodable length is four when the optional check character is present.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 03 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (03-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODABAR FIXED LENGTH 1

Product Reference Guide

5-247

Page 296

Programming

Codabar Fixed Length 2 This feature specifies Codabar second fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixed-length decoding. NOTE

Decodable length is four when the optional check character is present. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 00, or 03 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (03-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODABAR FIXED LENGTH 2

5-248

®

Magellan

2200VS and 2300HS

Page 297

Codabar Enable

Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.

CODABAR STITCHING = DISABLE

CODABAR STITCHING = ENABLE

Product Reference Guide

5-249

Page 298

Programming

Code 93 Enable Enables/disables the ability of the scanner to decode Code 93 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

CODE 93 = DISABLE

CODE 93 = ENABLE

5-250

®