Interleaved 2 of 5 (I 2 OF 5) Enable
I 2 of 5 Minimum Label Length This feature specifies the minimum allowable length of an I 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding. NOTE
Minimum label length should be less than or equal to maximum label length.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 02 to 50, even numbers only. Pad all single digit numbers with a leading zero to yield a two-digit entry (02-50). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET I 2 OF 5 MINIMUM LABEL LENGTH
Product Reference Guide
5-231
Page 280
Programming
I 2 of 5 Fixed Length 1 This feature specifies I 2 of 5 first fixed length. This applies when I 2 of 5 Length Control is set to fixedlength decoding. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 02 to 50, even numbers only. Pad all single digit numbers with a leading zero to yield a two-digit entry (02-50). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET I 2 OF 5 FIXED LENGTH 1
5-232
®
Magellan
2200VS and 2300HS
Page 281
Interleaved 2 of 5 (I 2 OF 5) Enable
I 2 of 5 Fixed Length 2 This feature specifies I 2 of 5 second fixed length. This applies when I 2 of 5 Length Control is set to fixed-length decoding. NOTE
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 00, or 02 to 50; even numbers only. Pad all single digit numbers with a leading zero to yield a two-digit entry (02-50). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET I 2 OF 5 FIXED LENGTH 2
Product Reference Guide
5-233
Page 282
Programming
I 2 of 5 Stitching Enables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
I 2 OF 5 STITCHING = DISABLE
I 2 OF 5 STITCHING = ENABLE
5-234
®
Magellan
2200VS and 2300HS
Page 283
Codabar Enable
Codabar Enable Enables/disables the ability of the scanner to decode Codabar labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODABAR = DISABLE
CODABAR = ENABLE
Product Reference Guide
5-235
Page 284
Programming
Codabar Start Stop Character Transmission Enables/disables transmission of Codabar start and stop characters. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODABAR START STOP CHARACTER TRANSMISSION = DISABLE
CODABAR START STOP CHARACTER TRANSMISSION = ENABLE
5-236
®
Magellan
2200VS and 2300HS
Page 285
Codabar Enable
Codabar Start Stop Character Set This feature selects the format of transmitted Codabar start/stop characters. Options are: •
ABCD/TN* E
•
ABCD/ABCD
• abcd/tn* e
• abcd/abcd
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page representing the desired option. You’ll need to cover any unused bar codes and facing pages to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODABAR START STOP CHARACTER = ABCD/TN* E
CODABAR START STOP CHARACTER = ABCD/ABCD
Product Reference Guide
5-237
Page 286
Programming
Codabar Start Stop Character Set, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
CODABAR START STOP CHARACTER = abcd/tn* e
CODABAR START STOP CHARACTER = abcd/abcd
5-238
®
Magellan
2200VS and 2300HS
Page 287
Codabar Enable
Codabar Start Stop Character Match Enables/disables the requirement that start and stop characters match. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODABAR START STOP CHARACTER MATCH = DISABLE
CODABAR START STOP CHARACTER MATCH = ENABLE
Product Reference Guide
5-239
Page 288
Programming
Codabar Check Character Calculation Enables/disables calculation and verification of an optional Codabar check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODABAR CHECK CHARACTER CALCULATION = DISABLE
CODABAR CHECK CHARACTER CALCULATION = ENABLE