Page 309
MSI/Plessey Enable
MSI/Plessey Number of Check Characters Specifies number of MSI/Plessey check characters to be calculated and verified.
Check characters are always modulus 10. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired number of MSI/ Plessey check characters to be calculated and verified. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/PLESSEY NUMBER OF CHECK CHARACTERS = 1
MSI/PLESSEY NUMBER OF CHECK CHARACTERS = 2
Product Reference Guide
5-261
Page 310
Programming
MSI/Plessey Check Character Transmission Enables/disables transmission of optional MSI/Plessey check characters. This feature applies only when MSI/Plessey Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/PLESSEY CHECK CHARACTER TRANSMISSION = DISABLE
MSI/PLESSEY CHECK CHARACTER TRANSMISSION = ENABLE
5-262
®
Magellan
2200VS and 2300HS
Page 311
MSI/Plessey Enable
MSI/Plessey AIM ID This feature enables/disables transmission of the MSI/Plessey AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/PLESSEY AIM ID = DISABLE
MSI/PLESSEY AIM ID = ENABLE
Product Reference Guide
5-263
Page 312
Programming
MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.
SET MSI/PLESSEY LABEL ID
5-264
®
Magellan
2200VS and 2300HS
Page 313
MSI/Plessey Enable
MSI/Plessey Length Control This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
NOTE
If variable-length control was selected, you must now set the features MSI/Plessey Maximum Label Length and MSI/Plessey Minimum Label Length. If fixed-length control was selected, you must now set I 2 of 5 Fixed Length 1 and MSI/Plessey Fixed Length 2.
MSI/PLESSEY LENGTH CONTROL = VARIABLE-LENGTH
MSI/PLESSEY LENGTH CONTROL = FIXED-LENGTH
Product Reference Guide
5-265
Page 314
Programming
MSI/Plessey Maximum Label Length This feature specifies the maximum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This feature applies when MSI/Plessey Length Control is set to variable-length decoding. NOTE
Maximum label length should be greater than or equal to minimum label length.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET MSI/PLESSEY MAXIMUM LABEL LENGTH
5-266
®
Magellan
2200VS and 2300HS
Page 315
MSI/Plessey Enable
MSI/Plessey Minimum Label Length This feature specifies the minimum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/Plessey Length Control is set to variable-length decoding. NOTE
Minimum label length should be less than or equal to maximum label length.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET MSI/PLESSEY MINIMUM LABEL LENGTH
Product Reference Guide
5-267
Page 316
Programming
MSI/Plessey Fixed Length 1 This feature specifies MSI/Plessey first fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET MSI/PLESSEY FIXED LENGTH 1
5-268
®
Magellan
2200VS and 2300HS
Page 317
MSI/Plessey Enable
MSI/Plessey Fixed Length 2 This feature specifies MSI/Plessey second fixed length. This applies when MSI/Plessey Length Control is set to fixedlength decoding. NOTE
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 0 (zero), or 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (00, 04-16). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET MSI/PLESSEY FIXED LENGTH 2
Product Reference Guide
5-269
Page 318
Programming
MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/ Plessey bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
MSI/PLESSEY STITCHING = DISABLE
MSI/PLESSEY STITCHING = ENABLE
5-270
®
Magellan