Spec sheet for the THE series of 1/8 DIN microprocessor-based temperature controllers from Datasensor, covering models ES-000 to ES-111 and ED-000 to ED-111, the ED-100 among them. It gives the technical data, the measurement scales and alarm functions, the wiring of the relay and transistor versions, the panel cutout and the order codes.

Device type
1/8 DIN microprocessor-based temperature controller, 48x96 mm format (THE series) p. 1
Power supply
12-24 Vac/Vdc ±10% version or 80-240 Vac ±10% version; 5 VA max. p. 2
Sensor input
E, J, K, L, R, S, T thermocouples and Pt100Ω/0°C RTDs p. 2
Control action
On/off or PID, automatic or manual, with AT autotuning and ADT autoadaptive functions p. 2
Main output
Relay SPDT 250 Vac, 5 A version or PNP transistor 15 Vdc ±20% version p. 2
Display
ED models: 4 digit red display (10mm) and 4 digit green display (7mm) p. 2
Alarm outputs
2nd point relay SPDT 250 Vac, 5 A; 3rd point relay SPST 250 Vac, 5 A; 16 alarm functions or fixed points p. 1, 2
Precision
Thermocouple ±0.4% f.s.; RTD ±0.3% f.s. p. 2
Front keys
PROG, SET, UP, DOWN, AUTO/MAN push-buttons p. 2
Connection
Terminal block with 15 screw contacts; electronic block extractable from front panel p. 2
Panel cutout
45 x 90 mm p. 3
Protection
IP54 front panel, IP20 housing, IP10 contacts p. 2
Housing and weight
ABS housing; 400 g max. p. 2
Operating temperature
-10 ... +55°C p. 2

What this sheet walks you through

  • Wiring the relay and transistor versions p. 3
  • Cutting the panel opening for mounting p. 3
  • Measurement ranges in °C and °F for each sensor type p. 2
  • Choosing an alarm or fixed point function p. 2
  • Ordering a model by display, supply, output and points p. 4

Good to know

  • Relay outputs are rated 250Vac 5A max. into a resistive load. p. 3
  • The transistor output version has 20 mA short-circuit protection. p. 2
  • The spec sheet states EN 61010-1 as the reference standard and electric protection class 1. p. 2

Questions this sheet answers

Which sensors can the ED-100 temperature controller read?

The THE series accepts E, J, K, L, R, S and T thermocouples and Pt100 RTDs, selectable in °C or °F. p. 2

What panel cutout does an ED-100 need?

The sheet gives a panel cutout of 45 x 90 mm. p. 3

What supply voltages do the THE series controllers use?

They come in a 12-24 Vac/Vdc ±10% version or an 80-240 Vac ±10% version, drawing 5 VA max. p. 2

Does the ED-100 autotune its PID settings?

The THE series PID action tunes itself with AT initial autotuning or keeps adapting with the ADT autoadaptive function. p. 1

The file

Size and text

Pages4
PDF121 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Datalogic ED-100 Spec Sheet

The text of page 1, from the PDF itself

TEMPERATURE CONTROLLERS

1/8 DIN µP BASED CONTROLLERS

  • Main control output with 1 or 2 auxiliary outputs
  • PID action with AT autotuning and ADT autoadaptive functions
  • Complete diagnostic of the regulation loop
  • Automatic or manual regulation of the output

THE SERIES The wide range of auxiliary functions available completes the excellent performances offered by the microprocessor-based controllers of the THE series, with standard 48x96 mm format and single and double display versions. The main PID control action adjusts itself automatically to the optimum parameters with the AT initial autotuning, or with the ADT permanent autoadaptive function; while the auxiliary outputs can be programmed on 16 different alarm functions or fixed points. The LFA diagnostic function is able to detect failures along the entire regulation loop, from the sensor to the actuator; moreover the regulation can be either automatic (closed loop) or manual (open loop), setting the output percentual value. The complete programming of the controllers is made through the front panel, with the possibility of including a 3 level software safety lock.

Page 2 of Datalogic ED-100 Spec Sheet

The text of page 2, from the PDF itself

TECHNICAL DATA Power supply: ............................................... 12-24 Vac/Vdc ±10% version, or 80-240 Vac ±10% version Consumption: ............................................... 5 VA max. Sensor input: ................................................ selectable between E, J, K, L, R, S, T thermocouples and Pt100Ω/0°C RTDs Measurement scale: ..................................... selectable in °C or °F scales with lower and upper limits, refer to table 1 Precision: ...................................................... thermocouple measurement ±0,4% f.s. RTD measurement ±0,3% f.s. temperature drift 0,01% f.s. / °C of ambient temperature setting and indication ±1 digit Data updating: .............................................. input, output and indication every 500 ms Data retention: .............................................. non volatile eeprom memory Keyboard correction indication: ................. from -99,9 to +99,9 °C/°F 1st point control action: .............................. on/off or PID automatic or manual selection, maximum or minimum, with AT initial autotuning and ADT permanent autoadaptive functions Proportional band: ....................................... 20°C (sel. from 1 to 999 °C/°F) Integral time: ................................................. 120 sec. (sel. from 0 to 960 sec.) Derivative time: ............................................ 30 sec. (sel. from 0 to 240 sec.) Cycle time: .................................................... 12 sec. (sel. from 1 to 120 sec.) On/off hysteresis: ......................................... ±1 °C (sel. from ±0,1 o ±99,9° C/°F) 1st point output type: .................................. relay SPDT 250 Vac, 5 A version trans. PNP 15 Vdc ±20% version 20 mA short-circuit protection 2nd/3rd point alarm action: ......................... selectable alarm setting from-999 to +999 °C/°F respect to 1st point, or fixed point setting on selected scale, refer to table 2 2nd point output type: ................................. relay SPDT 250 Vac, 5 A 3rd point output type: .................................. relay SPST 250 Vac, 5 A Auxiliary functions: ...................................... LFA Loop Failure Alert diagnostic function, digital filter with an average of 10 measures, SW program LOCK with 3 levels Setting: .......................................................... PROG, SET, UP, DOWN, AUTO/MAN push-buttons Indicators: ..................................................... 4 digit red display (10mm height), 4 digit green display (7mm height) for ED or 5 LED movement bar (ES), yellow ON1 LED, red ON2 LED, red AUX LED, green LOCK, green MAN LED, green AT LED Connection: .................................................. terminal block with 15 screw contacts, electronic block extractable from front panel Electric protection: ...................................... class 1 Mechanical protection: ................................ IP54 - front panel IP20 - housing IP10 - contacts Housing material: ......................................... ABS Weight: .......................................................... 400 g max. Operating temperature: ............................... -10 ... +55°C Storage temperature: ................................... -20 ... +65°C Reference standard: .................................... EN 61010-1 Certifications: ...............................................

UNI EN ISO9001

UNI EN ISO14000

TABLES Sensor TR int. TR dec. TC - E TC - J TC - K TC - L TC - S TC - R TC - T

°C scale

  • 150 ... 450
  • 99,9 ... 450 0 ... 600
  • 50 ... 760
  • 100 ... 1250
  • 50 ... 760 0 ... 1700 0 ... 1700
  • 100 ... 400

°F scale

  • 200 ... 850 -99,9 ... 850 0 ... 1100
  • 50 ... 1400
  • 150 ... 2300
  • 50 ... 1400 30 ... 3000 30 ... 3000
  • 150 ... 750

Table 1: °C/°F SCALE Alarm ALx0 ALx1 ALx2 ALx3 ALx4 ALx5 ALx6 ALx7 ALx8

Fixed pt FPx0 FPx1 FPx2 FPx3 FPx4 FPx5 FPx6 FPx7 FPx8

Function deactivated minimum maximum neutral zone on neutral zone off minimum* maximum* neutral zone on* neutral zone off*

*stand-by: first intervention inhibition

Table 2: ALARM FUNCTION

Page 3 of Datalogic ED-100 Spec Sheet

The text of page 3, from the PDF itself

CONNECTIONS RELAY VERSION

1. OUTPUT

2. OUTPUT

250Vac 5A max. RESISTIVE LOAD

250Vac 5A max. RESISTIVE LOAD

TRANSISTOR VERSIONPOWER SUPPLY1. OUTPUT2. OUTPUT(5A max.)(5A max.)3. OUTPUTPOWER SUPPLY

250Vac 5A max. RESISTIVE LOAD

3. OUTPUT

DIMENSIONS

Panel cutout: 45 x 90 mm mm

Page 4 of Datalogic ED-100 Spec Sheet

The text of page 4, from the PDF itself

MODELS DISPLAY single single single single single single single single double double double double double double double double

POWER SUPPLY 12 ... 24 Vdc/Vac 12 ... 24 Vdc/Vac 80 ... 240 Vac 80 ... 240 Vac 12 ... 24 Vdc/Vac 12 ... 24 Vdc/Vac 80 ... 240 Vac 80 ... 240 Vac 12 ... 24 Vdc/Vac 12 ... 24 Vdc/Vac 80 ... 240 Vac 80 ... 240 Vac 12 ... 24 Vdc/Vac 12 ... 24 Vdc/Vac 80 ... 240 Vac 80 ... 240 Vac

MAIN OUTPUT relay transistor relay transistor relay transistor relay transistor relay transistor relay transistor relay transistor relay transistor

POINTS 2 2 2 2 3 3 3 3 2 2 2 2 3 3 3 3

CODE N° 975021000 975021010 975021020 975021030 975201060 975201070 975201110 975201120 975031000 975031010 975031020 975031030 975151070 975151080 975151120 975151130

TEMPERATURE CONTROLLERS

MODEL ES-000 ES-010 ES-100 ES-110 ES-001 ES-011 ES-101 ES-111 ED-000 ED-010 ED-100 ED-110 ED-001 ED-011 ED-101 ED-111

Distributed by
DATASENSOR SpA via Lavino, 265 - 40050 Monte San Pietro, BO - Italy Tel. +39 051/6765611 • Fax +39 051/6759324 www.datasensor.com • e-mail info@datasensor.com Datasensor SpA endeavours to continuously improve and renew its products; for this reason the technical data and contents of this catalogue may undergo variations without prior notice. For correct installation and use Datasensor SpA can guarantee only the data indicated in the instruction manual supplied with the products.

Printed in Italy in July 2005 Rev. 02