The text of a manual · part 6 of 15
DS6300 Reference Manual: INSTALLATION, pages 21 to 30
Pages 21 to 30 of 105, from DS6300 Reference Manual
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-6300
Page 21
INSTALLATION
2
2 INSTALLATION To install the system follow the given procedure: • Select the mounting location for DS6300; • Mount the DS6300 scanner; • Position the scanner with respect of the barcode; • Proceed with system electrical connection; • Install the GENIUS™ program on the PC; • Adjust the focus position to the reading plane of the barcode.
WARNING
When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved.
Refer to the Reference Documentation for details on connecting your DS6300 reader to other devices in the system (i.e. C-BOX 100 etc.). NOTE
2.1 PACKAGE CONTENTS Verify that the DS6300 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: • DS6300 reader • Installation Quick Reference + barcode test chart • DS6300 configuration CD-ROM • Mounting bracket and screws
Figure 6 - DS6300 Package Contents
7
Page 22
DS6300
2
2.2 MECHANICAL MOUNTING 2.2.1
Mounting the Scanner
The DS6300 reader can be positioned and installed in the best way possible as a result of the Step-a-Head™ feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position. The reading head and the decoder base can be rotated independently from each other allowing the installation even in the most critical locations.
Head Screws
Fixing Screw (4)
Figure 7 - Step-A-Head™ Feature
To rotate the head follow the given procedure: 1. detach the head from the base by unscrewing the four fixing screws; 2. rotate the head in the desired position; 3. loosen but don't remove the two screws on top of the head; 4. affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half-way; 5. completely tighten the two screws on top of the head; 6. completely tighten the four fixing screws.
8
Page 23
INSTALLATION
2
The following diagrams give the overall dimensions of the reader standard model, the oscillating mirror model and mounting brackets. They may be used for their installation. Refer to par. 2.5 for correct positioning of the scanner with respect to the code passage zone.
30 1.18
60 2.36
16.5 0.65 85 3.34
74 2.85
99 3.90
30 1.18
76 2.99
113 4.45 mm inch
110 4.33
Figure 8 - DS6300 Overall Dimensions
42 1.65 10 0.4
4 0.15 50 82 1.96 3.22
82 3.22 25 50 1.96 0.98 20 18 0.78 0.71 N°2
22 0.86
126 4.96
2 N° °2 .1 N Ø40.16 Ø
106°
50 1.96 72 2.83 100 3.93
= =
OTS °2 SL S 8.5 N °2 SLOT N .5 0.33 Ø8 .33 Ø0
73.2 2.88 36 1.41
= =
130 5.12
35 1.37
S OT SL TS ° 4 SLO N 4 4.5 8 N° 0.1 mm inch
Figure 9 – ST-237 Mounting Bracket Overall Dimensions
9
Page 24
DS6300
60 2.36
30 1.18
2
16.5 0.65
99 3.90
63.5 2.50
104.5 4.11
85 3.35
69 2.72
113 4.45
114 4.48
102 4.01
110.3 4.34
56 2.20 mm inch
180 7.08
Figure 10 - DS6300 Oscillating Mirror Model Overall Dimensions
42 1.65 22 0.86
4 0.15
35 1.37
5.11
130
82 3.22 50 1.96 20 0.78
50 1.96
25 0.98
18 0.71
10 0.4
Ø4.1 0.16
R1
11 0.43 14 0.55
50 1.96 72 2.83 100 3.93
R5
11 0.43 14 0.55
75 2.95
R22
36 1.41
R36
Ø8 mm inch
.5
Figure 11 – ST-210 Mounting Bracket Overall Dimensions
10
Page 25
INSTALLATION
2.2.2
2
Mounting the Scanner with Accessories
The following accessories allow installing the DS6300 reader in the most suitable position for your network layout: -
ST-237 mounting bracket;
-
ST-210 mounting bracket;
-
FBK-6000 fast bracket.
The ST-237 is a 106° mounting bracket to be mounted on the reader as displayed in the image below:
Figure 12 – Mounting the ST-237 Mounting Bracket
The ST-210 is a 90° mounting bracket to be mounted on the reader as displayed in the image below:
Figure 13 – Mounting the ST-210 Mounting Bracket
11
Page 26
DS6300
2
The FBK-6000 is a fast bracket kit allowing a quick and easy mounting of the scanner on either the ST-210 or the ST-237 brackets. First, it is necessary to fix the FBX-6000 to the DS6300 scanner by means of the mounting screws:
Figure 14 – Mounting the FBK-6000 on the Scanner
Then, attach the assembly to the mounting bracket by slipping the hook into the bracket hole. Finally, fix it by means of the 2 fixing screws:
Figure 15 – Mounting the Assembly on the Bracket
12
Page 27
INSTALLATION
2.2.3
2
Mounting the Scanner with GFX-60
The GFX-60 is an X-pattern mirror for the DS6300 Series Scanners. The following procedure describes how to mount the GFX-60. 1. Unscrew the upper cover of the scan head, which houses the scanner output window. a) Remove the two top head screws. b) Loosen all four fixing screws. head screws fixing screws (4)
c) Carefully remove the scanner output window from the scan head.
2. Mount the GFX-60 onto the scan head paying attention to correctly align the sealing gasket. 3. Start the four fixing screws and the two head screws partially to assure correct alignment to the scan head. 4. Completely tighten the two head screws. 5. Completely tighten the four fixing screws.
13
Page 28
DS6300
2
6. Mount the scanner at an angle of 16°, as indicated in figure below, in order to obtain an angle of 90° between the two scan lines. This guarantees an omni directional reading of the barcode, if the code label satisfies the ACR™ 4 conditions (see par. 4.1).
The DS6300 with the GFX-60 can be mounted over a conveyor in different positions. The following picture illustrates the suggested position offering the best compromise between width and height of the reading area:
Figure 16 – Central Reading Position
The Central Reading position allows maximizing the reading distance (height) when the width of the reading area is not critical (narrow conveyors). In this case a complete reading on the central part of the conveyor plane is guaranteed.
To better exploit the scanner reading performance when GFX-60 is mounted, the use of a dedicated recipe is recommended. NOTE
For details about the reading performance of the DS6300 with GFX-60 see par. 4.3.3. 14
Page 29
INSTALLATION
2
2.3 ELECTRICAL CONNECTIONS All the connectors available for each scanner model are the following:
Scanner Model Master/Slave
Ethernet
DeviceNet
Profibus
Connector 25-pin male serial interface and I/O connector 9-pin male Lonworks connector* 9-pin female Lonworks connector 26-pin male serial interface and I/O connector 9-pin female Lonworks connector RJ45 modular connector 26-pin male serial interface and I/O connector 9-pin female Lonworks connector 5-pin male connector 26-pin male serial interface and I/O connector 9-pin female Lonworks connector 9-pin female Profibus connector (white)
* Do not connect an RS232 port to the 9-pin Lonworks Connector. This may damage your Laptop PC. CAUTION
15
Page 30
DS6300
2
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DS6300 reader is connected in a network by means of the C-BOX 100:
C-BOX 100 Terminal Block Connectors Power 1, 3, 5 2, 4, 6 7, 8 20, 40 27 28 29 30 31, 33 32, 34 36 21 22 23 24 25 26 35 37 38, 39 Pin
VS GND EARTH GROUND Reserved Inputs EXT TRIG/PS A (polarity insensitive) for PS EXT TRIG/PS B (polarity insensitive) for PS IN 2/ENC A (polarity insensitive) for Encoder IN 2/ENC B (polarity insensitive) for Encoder IN 3A (polarity insensitive) IN 4A (polarity insensitive) IN 3B/IN 4B Reference (polarity insensitive) Outputs OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A (polarity insensitive) OUT 3B (polarity insensitive) Auxiliary Interface TX AUX RX AUX GND Main Interface RS485 RS485 RS232 Full-Duplex Half-Duplex TX232 TX485+ RTX485+ RTS232 TX485RTX485RX232 * RX485+ CTS232 * RX485-
11, 15 12, 16 17 18 10, 14, 19 SGND Main Isolated 9, 13
SGND Main Isolated RS485 Cable Shield
20 mA C.L. (with INT-30 only)
see INT-30 instructions
SGND Main Isolated RS485 Cable Shield
* Do not leave floating, see par. "RS485 Full-Duplex Interface" for connection details.
16