Page 97

TECHNICAL FEATURES

7

7 TECHNICAL FEATURES ELECTRICAL FEATURES (see note 1) Supply voltage Power consumption Communication Interfaces

15 to 30 Vdc 15 W typical 20 W Max. (including startup current)

Main (isolated)

Baud Rate

RS232 RS485 full-duplex RS485 half-duplex 20 mA current loop

1200 to 115200 1200 to 115200 1200 to 115200

(INT-30 with C-BOX 100 only) Auxiliary

RS232

19200 1200 to 115200

Other

Lonworks Ethernet DeviceNet Profibus Inputs External Trigger 1, 3 auxiliary digital inputs Outputs (optocoupled), 3 software programmable digital outputs OPTICAL FEATURES (see note 1) Light receiver Wavelength Safety class Laser control READING FEATURES Scan rate Maximum resolution Max. reading distance Max. reading width Max. depth of field USER INTERFACE LCD Display Keypad LED indicators

Note 1:

1.25 Mb/s 10 or 100 Mb/s 125 or 250 Kb/s 12 Mb/s (optocoupled NPN or PNP)

(optocoupled)

Avalanche photodiode 630 to 680 nm Class 2 - EN60825-1; Class II - CDRH Security system to turn laser off in case of motor slow down 600-1200 scans/s

(see reading diagrams)

2 lines by 16 characters LCD 3 keys Power ON (red) Phase ON (yellow) TX data (green)

The features given are typical at 25 °C ambient temperature (if not otherwise indicated).

83

Page 98

DS6300

7 SOFTWARE FEATURES Readable codes

Code selection Headers and Terminators Operating modes

Configuration modes Parameter storage

Interleaved 2/5 Code 39 standard Codabar Code 128 EAN128 Code 93 (Standard and Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Up to 10 codes during one reading phase Transmitted messages can be personalized using up to 128-byte headers and 128-byte terminators On Line Automatic Test Genius™ utility program Non-volatile internal FLASH

ENVIRONMENTAL FEATURES Operating temperature Storage temperature Humidity Ambient light immunity Vibration resistance IEC 68-2-6 test FC

0° to +40 °C (+32° to +104 °F) -20° to +70 °C (-4° to +158 °F) 90% non condensing 3500 lux 14 mm @ 2 to 10 Hz 1.5 mm @ 13 to 55 Hz 2 g @ 70 to 200 Hz 2 hours on each axis 30 g; 11 ms; 3 shocks on each axis IP64*

Shock resistance IEC 68-2-27 test EA Protection class PHYSICAL FEATURES Mechanical dimensions Weight *

84

Standard Models

Oscillating Mirror Models

110 x 113 x 99 mm (4.33 x 4.45 x 3.9 in) 1.5 kg. (3.3 lb)

113 x 180 x 104.5 mm (4.45 x 7.08 x 4.11 in) 2.0 kg. (4.4 lb)

IP50 grade for standard Ethernet versions.

Page 99

GLOSSARY ACR™ 4 Each version of the base has the powerful code reconstruction technology (ACR™ 4). The new fourth generation ACR considerably increases the code reconstruction reading capability in the case of damaged or very tilted barcodes. Aperture Term used on the required CDRH warning labels to describe the laser exit window. Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in machine-readable form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format. Barcode Label A label that carries a barcode and can be affixed to an article. Baud Rate A unit used to measure communications speed or data transfer rate. CDRH (Center for Devices and Radiological Health) This organization (a service of the Food and Drug Administration) is responsible for the safety regulations governing acceptable limitations on electronic radiation from laser devices. Datalogic devices are in compliance with the CDRH regulations. Code Positioning Variation in code placement that affects the ability of a scanner to read a code. The terms Pitch, Skew, and Tilt deal with the angular variations of code positioning in the X, Y and Z axes. See par. 2.5. Variations in code placement affect the pulse width and therefore the decoding of the code. Pulse width is defined as a change from the leading edge of a bar or space to the trailing edge of a bar or space over time. Pulse width is also referred to as a transition. Tilt, pitch, and skew impact the pulse width of the code. EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Full Duplex Simultaneous, two-way, independent transmission in both directions. Half Duplex Transmission in either direction, but not simultaneously. Host A computer that serves other terminals in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages.

85

Page 100

Interface A shared boundary defined by common physical interconnection characteristics, signal characteristics and meanings of interchanged signals. LED (Light Emitting Diode) A low power electronic device that can serve as a visible or near infrared light source when voltage is applied continuously or in pulses. It is commonly used as an indicator light and uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD). LEDs have extremely long lifetimes when properly operated. Multidrop Line A single communications circuit that interconnects many stations, each of which contains terminal devices. See RS485. Parameter A value that you specify to a program. Typically parameters are set to configure a device to have particular operating characteristics. Pitch Rotation of a code pattern about the X-axis. The normal distance between center line or adjacent characters. See par. 2.5. Position The position of a scanner or light source in relation to the target of a receiving element. Protocol A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. Resolution The narrowest element dimension which can be distinguished by a particular reading device or printed with a particular device or method. RS232 Interface between data terminal equipment and data communication equipment employing serial binary data interchange. RS485 Interface that specifies the electrical characteristics of generators and receivers for use in balanced digital multipoint systems such as on a Multidrop line. Scanner A device that examines a printed pattern (barcode) and either passes the uninterpreted data to a decoder or decodes the data and passes it onto the Host system. Serial Port An I/O port used to connect a scanner to your computer, identifiable by a 9-pin or 25-pin connector. Signal An impulse or fluctuating electrical quantity (i.e.: a voltage or current) the variations of which represent changes in information.

86

Page 101

Skew Rotation about the Y-axis. Rotational deviation from correct horizontal and vertical orientation; may apply to single character, line or entire encoded item. See par. 2.5. Step-a-Head™ Step-a-Head™ makes it possible to rotate the reader head and the decoder base independently from each other. As a result of the Step-a-Head™, the DS6300 can always be installed in the ideal position. It is possible to change the orientation of the connector panel while the laser window remains in the desired position. Symbol A combination of characters including start/stop and checksum characters, as required, that form a complete scannable barcode. Tilt Rotation around the Z axis. Used to describe the position of the barcode with respect to the laser scan line. See par. 2.5. Trigger Signal A signal, typically provided by a photoelectric sensor or proximity switch, which informs the scanner of the presence of an object within its reading zone. UPC Acronym for Universal Product Code. The standard barcode type for retail food packaging in the United States. Visible Laser Diode A light source used in scanners to illuminate the barcode symbol. Generates visible red light at wavelengths between 630 and 680 nm.

87