Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 15

DS6300 Reference Manual: READING FEATURES

Pages 79 to 91 of 105, from DS6300 Reference Manual

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-6300

Page 79

READING FEATURES

4

4 READING FEATURES 4.1 ADVANCED CODE RECONSTRUCTION (ACR™ 4) The traditional way of barcode reading could be called “Linear Reading”. In this case, the laser beam crosses the barcode symbol from its beginning to its end as shown in the following figure:

Laser Beam

Figure 74 – Linear Reading

In Advanced Code Reconstruction mode it is no longer necessary for the laser beam to cross the label from the start to the end. With just a set of partial scans on the label (obtained using the motion of the label itself), the DS6300 is able to “reconstruct” the barcode. A typical set of partial scans is shown in the figure below:

Code Direction

Figure 75 – Partial Scans

None of the partial scans contains the whole label. The decoder aligns each partial scan correctly and combines them in order to obtain the entire code. The alignment is performed by calculating the time difference from one partial scan to another using a reference code element.

4.1.1

Tilt Angle for Advanced Code Reconstruction

The most important parameter in Advanced Code Reconstruction is the value of the maximum tilt angle (α maximum) under which the code reconstruction process is still possible.

Laser Beam 0° to α max

α = tilt angle

α Figure 76 – Tilt Angle

65

Page 80

DS6300

4 The decoder will be able to read the label + α max and - α max as shown in the following figure:

with a tilt angle between

0° OK

OK

Conveyor

-α +α

OK

No Read

No Read

No Read

OK

OK

Laser Beam Figure 77 – Reading Zones with α Max

4.2 PERFORMANCE The scan rate is 800 scans/sec. Refer to the diagrams in par. 4.3 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25 °C ambient temperature depending on the conditions listed under each diagram.

4.2.1 • •

Reading Conditions

ANSI Grade B minimum 800 scans/sec

The following tables describe the requirements for standard applications.

Conveyor Speed (m/s) 0.25 0.30 2/5 Interleaved 0.33 Code Resolution 0.38 (mm) 0.50 0.72 1.00

0.5 10 12 13 14 18 24 33

Minimum Code Height for ACR Reading (mm) 45° 30° 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 12 14 16 18 20 7 9 10 12 13 14 15 17 19 21 8 9 11 12 14 14 16 18 20 22 8 10 11 13 14 16 18 19 21 23 9 11 12 14 15 19 21 23 25 26 11 12 14 15 17 25 27 28 30 32 15 16 17 19 20 34 35 36 38 40 20 21 22 23 25

Ratio 3:1 Table 1

66

3 15 15 16 17 18 22 26

Page 81

READING FEATURES

Conveyor Speed (m/s) 0.25 0.30 Code 39 0.33 Code Resolution 0.38 (mm) 0.50 0.72 1.00

4

0.5 9 10 11 12 15 20 27

Minimum Code Height for ACR Reading (mm) 45° 30° 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 10 12 14 16 17 6 7 9 10 12 11 13 15 17 18 7 8 9 11 12 12 13 15 17 19 7 8 10 11 13 13 14 16 18 20 8 9 10 12 13 16 17 18 20 22 10 10 11 13 14 21 22 23 24 26 13 13 14 15 17 28 29 30 31 32 17 17 18 19 20

3 13 14 14 15 16 18 21

Ratio 3:1; Interdigit = Module Size Table 2

Conveyor Speed (m/s) 0.25 0.30 Code 128 – Ean 128 0.33 Code Resolution 0.38 (mm) 0.50 0.72 1.00

0.5 8 8 9 10 12 16 22

Minimum Code Height for ACR Reading (mm) 45° 30° 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 9 11 13 15 17 5 7 8 10 11 10 12 14 16 18 6 7 9 10 12 11 13 14 16 18 6 8 9 11 12 11 13 15 17 19 7 8 10 11 13 13 15 17 19 21 8 9 11 12 14 17 19 21 22 24 10 11 13 14 16 23 24 25 27 29 13 14 15 17 18

3 13 13 14 14 15 17 20

Table 3

Conveyor Speed (m/s) 0.25 0.30 Codabar 0.33 Code Resolution 0.38 (mm) 0.50 0.72 1.00

0.5 8 9 9 10 13 17 23

Minimum Code Height for ACR Reading (mm) 45° 30° 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 9 11 13 15 17 5 7 8 10 11 10 12 14 16 18 6 7 9 10 12 11 13 14 16 18 6 8 9 11 12 11 13 15 17 19 7 8 10 11 13 14 15 17 19 21 8 9 11 12 14 18 19 21 22 24 11 12 13 14 16 24 25 26 27 29 14 15 16 17 18

3 13 13 14 14 15 17 20

Ratio 3:1; Interdigit = Module Size Table 4

Conveyor Speed (m/s) 0.25 0.30 EAN 8-13, UPC-A 0.33 Code Resolution 0.38 (mm) 0.50 0.72 1.00

0.5 7 8 9 10 12 16 22

Minimum Code Height for ACR Reading (mm) 45° 30° 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 9 10 12 14 16 5 6 8 9 11 9 11 13 15 17 6 7 8 10 11 10 11 13 15 17 6 7 9 10 12 11 12 14 16 18 7 7 9 10 12 13 14 15 17 19 8 9 10 11 13 17 18 19 20 22 10 11 12 13 14 23 24 24 25 26 13 14 15 16 16

3 12 13 13 13 14 16 18

Table 5 67

Page 82

DS6300

4

4.3 READING DIAGRAMS

4.3.1

DS6300 Standard Model

DS6300-100-0XX - Resolution: 0.20 mm/8 mils

10

0

6

8

10 12 14

16

18

20 22

0

15

20

25

40

45

50

25

8

20

6

15

CONDITIONS 4 Code = Interleaved 2/5 2 or Code 39 PCS = 0.90 0 Pitch angle = 0° Skew angle = 10° - 20° -2 Tilt angle = 0°

Focus Position = 0

30

35

55

24 (in) 60

(cm)

Focus Position = 40

10 5 0 -5

-4

-10

-6

-15

-8

-20

-10

-25

(in) (cm) Figure 78 – Standard Model 0.20 mm / 8 mils Reading Diagram Note: (0,0) is the center of the laser beam output window.

68

Page 83

READING FEATURES

4

DS6300-100-0XX - Resolution: 0.30 mm/12 mils 0

8

10

12 14 16

18

20

0

20

25

30

45

50

12

30

10

25

8

20

6

15

4

10

2

5

0

0

-2

-5

-4

-10

-6

-15

-8

-20

-10

-25

-12

-30

35

40

22 24 55

60

26 28

30

32 34 (in)

70

75

80

65

85 (cm)

Focus Position = 0

Focus Position = 40

Focus Position = 60

(in) (cm) Figure 79 - Standard Model 0.30 mm / 12 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

69

Page 84

DS6300

4 DS6300-100-0XX - Resolution: 0.38 mm/15 mils 0

12

14

0 16 40

30

35

16 18 40

45

20

22

24

50

55

60

26 28 65

70

30

32

34

36 38

75

80

85

90

40

95 100 105 110 (cm)

14 35 12 30 10 25

Focus Position = 0

8 20 6 15 4 10 2

5

0

0

Focus Position = 100

-2 -5 -4 -10 -6 -15 -8 -20 -10 -25

Focus Position = 60

-12 -30 -14 -35 -16 -40 (in) (cm) Figure 80 - Standard Model 0.38 mm / 15 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

70

42 44 (in)

Page 85

READING FEATURES

4

DS6300-100-0XX - Resolution: 0.50 mm/20 mils

24

0

8

12

0

20

30

16 20 24 40

50

60

28

32

70

80

36 40

44

48 52 56

(in)

90 100 110 120 130 140 150 (cm)

60

20

50

16

40

12

30

8

20

4

10

0

0

-4

-10

-8

-20

-12

-30

-16

-40

-20

-50

-24

-60

Focus Position = 100

Focus Position = 60

Focus Position = 0

(in) (cm) Figure 81 - Standard Model 0.50 mm / 20 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

71

Page 86

DS6300

4

4.3.2

DS6300 Oscillating Mirror Model

DS6300-105-0XX (oscillating mirror) - Resolution: 0.20 mm/8 mils

0

6

8

0

15

20

10

25

8

20

6

15

4

10 12 14

16

18

25

40

45

30

35

Focus Position = 0

20 22 50

55

24 (in) 60

(cm)

Focus Position = 40

10

2

5

0

0

-2

-5

-4

-10

-6

-15

-8

-20

-10

-25

(in) (cm) Figure 82 – Oscillating Mirror Model 0.20 mm / 8 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

72

Page 87

READING FEATURES

4

DS6300-105-0XX (oscillating mirror) - Resolution: 0.30 mm/12 mils 0

8

10

0

20

25

12

30

10

25

8

20

6

15

4

10

2

5

0

0

-2

-5

-4

-10

-6

-15

-8

-20

-10

-25

-12

-30

12 14 16 30

35

40

18

20

45

50

22 24 55

60

26 28

30

32 34 (in)

70

75

80

65

85 (cm)

Focus Position = 0 Focus Position = 40

Focus Position = 60

(in) (cm) Figure 83 - Oscillating Mirror Model 0.30 mm / 12 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

73

Page 88

DS6300

4 DS6300-105-0XX (oscillating mirror) - Resolution: 0.38 mm/15 mils 0

10

12

0 16 40

25

30

14 16 35

40

18

20

22

24

26 28 30

32

34

36

38

45

50

55

60

65

80

85

90

95 100 105 (cm)

70

75

14 35 12 30 10 25

Focus Position = 0

8 20 6 15 4 10 2

5

0

0

Focus Position = 100

-2 -5 -4 -10 -6 -15 -8 -20 -10 -25

Focus Position = 60

-12 -30 -14 -35 -16 -40 (in) (cm) Figure 84 - Oscillating Mirror Model 0.38 mm / 15 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

74

40

42 (in)

Page 89

READING FEATURES

4

DS6300-105-0XX (oscillating mirror) - Resolution: 0.50 mm/20 mils 0

8

12

0

20

30

24

60

20

50

16

40

12

30

8

20

4

10

0

0

-4

-10

-8

-20

-12

-30

-16

-40

-20

-50

-24

-60

16 20 24 40

50

60

28

32

70

80

36 40

44

48 52 56

(in)

90 100 110 120 130 140 150 (cm) Focus Position = 100

Focus Position = 60

Focus Position = 0

(in) (cm) Figure 85 - Oscillating Mirror Model 0.50 mm / 20 mils Reading Diagram

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° Note: (0,0) is the center of the laser beam output window.

75

Page 90

DS6300

4

4.3.3

DS6300 with GFX-60

DS6300 with GFX-60 - Resolution: 0.20 mm/8 mils

Figure 86 – GFX-60 0.20 mm / 8 mils Reading Diagram

Note: 0 value on the X axis is measured from the nose of the GFX-60 0 value on the Y axis is measured from the conveyor plane focus position = 0

DS6XXX with GFX-60 - Resolution: 0.30 mm/12 mils

Figure 87 - GFX-60 0.30 mm / 12 mils Reading Diagram

Note: 0 value on the X axis is measured from the nose of the GFX-60 0 value on the Y axis is measured from the conveyor plane focus position = 40

76

Page 91

READING FEATURES

4

DS6XXX with GFX-60 - Resolution: 0.50 mm/20 mils

Figure 88 - GFX-60 0.50 mm / 20 mils Reading Diagram Note: 0 value on the X axis is measured from the nose of the GFX-60 0 value on the Y axis is measured from the conveyor plane focus position = 100

DS6XXX with GFX-60 - Resolution: 1.00 mm/40 mils

Figure 89 - GFX-60 1.00 mm / 40 mils Reading Diagram Note: 0 value on the X axis is measured from the nose of the GFX-60 0 value on the Y axis is measured from the conveyor plane focus position = 100

77