Page 31
COMMON FEATURES 7)
Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode.
Focus Adjustment Screw
The reader display shows the focus position only when the laser beam is activated. NOTE
It is possible to visualize the focus position and the reading percentage on the terminal tool provided by the Genius™ configuration program (see Genius™ Help On-Line for details).
Reading Conditions: • •
ANSI Grade B minimum 800 scans/sec
The following tables describe the requirements for standard applications.
Conveyor Speed (m/s)
2/5 Interleaved Code Resolution (mm)
0.25 0.30 0.33 0.38 0.50 0.72 1.00
0.5 10 12 13 14 18 24 33
1 12 14 14 16 19 25 34
Minimum Code Height for ACR Reading (mm) 45° 30° 1.5 2 2.5 3 0.5 1 1.5 2 14 16 18 20 7 9 10 12 15 17 19 21 8 9 11 12 16 18 20 22 8 10 11 13 18 19 21 23 9 11 12 14 21 23 25 26 11 12 14 15 27 28 30 32 15 16 17 19 35 36 38 40 20 21 22 23
2.5 13 14 14 15 17 20 25
3 15 15 16 17 18 22 26
2.5 12 12 13 13 14 17 20
3 13 14 14 15 16 18 21
Ratio 3:1
Table 1
Conveyor Speed (m/s)
Code 39 Code Resolution (mm)
0.25 0.30 0.33 0.38 0.50 0.72 1.00
0.5 9 10 11 12 15 20 27
1 10 11 12 13 16 21 28
Minimum Code Height for ACR Reading (mm) 45° 30° 1.5 2 2.5 3 0.5 1 1.5 2 12 14 16 17 6 7 9 10 13 15 17 18 7 8 9 11 13 15 17 19 7 8 10 11 14 16 18 20 8 9 10 12 17 18 20 22 10 10 11 13 22 23 24 26 13 13 14 15 29 30 31 32 17 17 18 19
Ratio 3:1; Interdigit = Module Size
Table 2
29
Page 32
COMMON FEATURES
Conveyor Speed (m/s)
Code 128 – Ean 128 Code Resolution (mm)
0.25 0.30 0.33 0.38 0.50 0.72 1.00
0.5 8 8 9 10 12 16 22
1 9 10 11 11 13 17 23
Minimum Code Height for ACR Reading (mm) 45° 30° 1.5 2 2.5 3 0.5 1 1.5 2 11 13 15 17 5 7 8 10 12 14 16 18 6 7 9 10 13 14 16 18 6 8 9 11 13 15 17 19 7 8 10 11 15 17 19 21 8 9 11 12 19 21 22 24 10 11 13 14 24 25 27 29 13 14 15 17
2.5 11 12 12 13 14 16 18
3 13 13 14 14 15 17 20
2.5 11 12 12 13 14 16 18
3 13 13 14 14 15 17 20
2.5 11 11 12 12 13 14 16
3 12 13 13 13 14 16 18
Table 3
Conveyor Speed (m/s)
Codabar Code Resolution (mm)
0.25 0.30 0.33 0.38 0.50 0.72 1.00
0.5 8 9 9 10 13 17 23
1 9 10 11 11 14 18 24
Minimum Code Height for ACR Reading (mm) 45° 30° 1.5 2 2.5 3 0.5 1 1.5 2 11 13 15 17 5 7 8 10 12 14 16 18 6 7 9 10 13 14 16 18 6 8 9 11 13 15 17 19 7 8 10 11 15 17 19 21 8 9 11 12 19 21 22 24 11 12 13 14 25 26 27 29 14 15 16 17
Ratio 3:1; Interdigit = Module Size
Table 4
Conveyor Speed (m/s)
EAN 8-13, UPC-A Code Resolution (mm)
0.25 0.30 0.33 0.38 0.50 0.72 1.00
0.5 7 8 9 10 12 16 22
1 9 9 10 11 13 17 23
Minimum Code Height for ACR Reading (mm) 45° 30° 1.5 2 2.5 3 0.5 1 1.5 2 10 12 14 16 5 6 8 9 11 13 15 17 6 7 8 10 11 13 15 17 6 7 9 10 12 14 16 18 7 7 9 10 14 15 17 19 8 9 10 11 18 19 20 22 10 11 12 13 24 24 25 26 13 14 15 16 Table 5
30
Page 33
COMMON FEATURES
Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window.
DS6300-100-0XX – Resolution: 0.20 mm/8 mils
10
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
0
6
8
10 12 14
16
18
20 22
0
15
20
25
40
45
50
30
35
55
25
8
20
6
15
4
10
2
5
0
0
-2
-5
-4
-10
-6
-15
-8
-20
-10
-25
24 (in) 60
(cm)
Focus Position = 40
Focus Position = 0
(in) (cm)
DS6300-100-0XX – Resolution: 0.30 mm/12 mils
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
0
8
10
12 14 16
18
20
0
20
25
30
45
50
12
30
10
25
8
20
6
15
4
10
2
5
0
0
-2
-5
-4
-10
-6
-15
-8
-20
-10
-25
-12
-30
35
40
22 24 55
60
26 28
30
32 34 (in)
70
75
80
65
85 (cm)
Focus Position = 0
Focus Position = 40
Focus Position = 60
(in) (cm)
31
Page 34
COMMON FEATURES
Reading Diagrams: DS6300-100-0XX – Resolution: 0.38 mm/15 mils 0
12
14
0 16 40
30
35
16 18 40
45
20
22
24
50
55
60
26 28
30
32
34
36 38
70
75
80
85
90
65
40
42 44 (in)
95 100 105 110 (cm)
14 35 12 30 10 25
Focus Position = 0
8 20 6 15
CONDITIONS 4 10 Code = Interleaved 2/5 or Code 39 2 5 PCS = 0.90 0 0 Pitch angle = 0° Skew angle = 10° - 20° -2 -5 Tilt angle = 0°
Focus Position = 100
-4 -10 -6 -15 -8 -20
-10 -25
Focus Position = 60
-12 -30 -14 -35 -16 -40 (in) (cm)
DS6300-100-0XX – Resolution: 0.50 mm/20 mils
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
8
12
0
20
30
24
60
20
50
16
40
12
30
8
20
4
10
0
0
-4
-10
-8
-20
-12
-30
-16
-40
-20
-50
-24
-60
(in) (cm)
32
0
16 20 24 40
50
60
28
32
70
80
36 40
44
Focus Position = 100 Focus Position = 60
Focus Position = 0
48 52 56
(in)
90 100 110 120 130 140 150 (cm)
Page 35
COMMON FEATURES
Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.20 mm/8 mils 0 0 10
25
8
20
6
15
4
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
6 15
8 20
10 12 14 25
30
16
35
40
18
20 22
45
55
50
Focus Position = 0
24 (in) 60
(cm)
Focus Position = 40
10
2
5
0
0
-2
-5
-4
-10
-6
-15
-8
-20
-10
-25
(in) (cm)
DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.30 mm/12 mils
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
0
8
10
0
20
25
12
30
10
25
8
20
6
15
4
10
2
5
0
0
-2
-5
-4
-10
-6
-15
-8
-20
-10
-25
-12
-30
12 14 16 30
35
40
18
20
45
50
22 24 55
60
26 28
30
32 34 (in)
70
75
80
65
85 (cm)
Focus Position = 0 Focus Position = 40
Focus Position = 60
(in) (cm)
33
Page 36
COMMON FEATURES
Reading Diagrams: DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.38 mm/15 mils 0
10
12
0 16 40
25
30
14 16 35
40
18
20
22
24
26 28 30
32
34
36
38
45
50
55
60
65
80
85
90
95 100 105 (cm)
70
75
40
42 (in)
14 35 12 30 10 25
Focus Position = 0
8 20 6 15
CONDITIONS 4 10 Code = Interleaved 2/5 or Code 39 2 5 PCS = 0.90 0 0 Pitch angle = 0° Skew angle = 10° - 20° -2 -5 Tilt angle = 0°
Focus Position = 100
-4 -10 -6 -15 -8 -20
Focus Position = 60
-10 -25 -12 -30 -14 -35 -16 -40 (in) (cm)
DS6300-105-0XX (Oscillating Mirror) – Resolution: 0.50 mm/20 mils
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0°
8
12
0
20
30
24
60
20
50
16
40
12
30
8
20
4
10
0
0
-4
-10
-8
-20
-12
-30
-16
-40
-20
-50
-24
-60
(in) (cm)
34
0
16 20 24 40
50
60
28
32
70
80
36 40
44
48 52 56
90 100 110 120 130 140 150 (cm) Focus Position = 100
Focus Position = 60
Focus Position = 0
(in)
Page 37
COMMON FEATURES
User Interface: RS232 PC-side connections 5
1
6
9
9-pin male connector Pin 2 3 5 7 8
1
13
14
25
25-pin male connector Name RX TX GND RTS CTS
Pin 3 2 7 4 5
Name RX TX GND RTS CTS
How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 25-pin D-sub female
9-pin D-sub female
21
TXAUX
2
RX
20
RXAUX
3
TX
5
GND
23 GND
PC
13 VS 25 GND
DS6300
9
VS
18 EXT TRIG A 19 EXT TRIG B
Power Supply VS (15 – 30 VDC) Power GND
Trigger
Compliance: Laser Safety
1
1
2 Figure A 1 Laser Safety Label
Figure B 1 Warning and Device Class Label
2 Identification Label
35
Page 38
COMMON FEATURES 1
Figure C 1 Laser Safety Label
The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius™ Help On-Line). AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE
AVOID EXPOSURE – LASER LIGHT IS EMITTED FROM THIS APERTURE
Laser Safety Label for Oscillating Mirror and Standard Models
CAUTION-CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM
LASER LIGHT – DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630 ~ 680 nm EN60825-1:2001
DATALOGIC S.p.A. Via Candini, 2 40012 LIPPO DI CALDERARA DI RENO (BO) ITALY MANUFACTURED VOLT Amp. JANUARY 2002 15-30 DC 1.5-0.5 MODEL No.
N2468
SERIAL No. This product conforms to the applicable requirements of 21CFR 1040 at the date of manufacture.
Warning and Device Class Label
Device Identification Label
The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 mW at 630 ~ 680 nm).
Power Supply -
This product is intended to be installed by Qualified Personnel only.
-
All DS6300 Models: This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25/26-pin connector.
CE Compliance Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
36
Page 39
DECLARATION OF CONFORMITY
07
Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS6300-XXX-XXX, Laser Scanner;
e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y
92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
2006/95/EC Low Voltage Directive
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (Class A ITE), August 1994: Amendment A1 (Class A ITE), October 2000:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
EN 61000-6-2, October 2001:
ELECTROMAGNETIC COMPATIBILITY (EMC) PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS
EN 60950-1, December 2001:
INFORMATION TECHNOLOGY EQUIPMENT – SAFETY – PART 1: GENERAL REQUIREMENTS
EN 60825-1, June 1994: Amendments A11 (1996), A2 (2001):
SAFETY OF LASER PRODUCTS – PART 1: EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER'S GUIDE
Lippo di Calderara, April 2nd, 2007
Lorenzo Girotti Product & Process Quality Manager
821000688 (Rev. I)