Page 41
DS6100
DATALOGIC
The voltage available on the input connector, between pins A and B, is physically the same as used to power the scanner. The electrical features of these inputs are: Maximum voltage
30 V
Maximum current
25 mA
2.5.5 Outputs Apart from the main and auxiliary interface outputs on the 19-pin circular connector (Figure B, 12 ), there are also indicator and power supply outputs for external devices. Pin A B C D E F G H
Name GND VS NO READNO READ+ RIGHTRIGHT+ SPSSPS+
Function power for external devices power for external devices + no read output no read output right code output right code output slave presence sensor slave presence sensor
A D.C. output voltage, the same as that powering the DS6100, is present between pins A and B. This may be used to power external devices: electrical isolation between the scanner and external devices is lost in this case. The NO READ output activates when a code signalled by the presence sensor is not decoded. The RIGHT output is used to signal the presence of a right code, thus a good decode condition. The NO READ and RIGHT outputs are all level or pulse programmable: a 50 ms pulse is generated in the second case. Further programming information is supplied in the WinHost Help File. These outputs are created using optoisolated Darlington drivers and supply both the collector and emitter in output, allowing both loads referenced to ground and to the power supply to be driven. 2.26 - Installation
Page 42
DATALOGIC
DS6100
The electrical features are given below: Collector-emitter voltage
30 V Max.
Collector current
130 mA Max.
Saturation voltage (VCE)
1 V at 10 mA Max.
Maximum power dissipation
90 mW at 50°C (Ambient temperature).
DS6100
USER INTERFACE Vext 30 Vdc max
D/F
NO READ+ RIGHT+
C/E
NO READRIGHT-
Figure 2.30 - Output interface
When the load is powered by an external power supply, the voltage must be less than 30 V. The limit requested by the maximum power dissipation is more important than that of the maximum collector current: if one of these outputs is continuously driven, the maximum current must not be more than 40 mA although 130 mA may be reached in pulse conditions.
2.6 POSITIONING The DS6100 scanner is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS6100 take into consideration these three ideal label position angles: Pitch 0°, Skew 10° to 30° and Tilt 0°.
Installation - 2.27
Page 43
DS6100
DATALOGIC
Follow the suggestions for the best orientation: P
The Pitch angle is represented by the value P in Figure 2.31. Position the reader in order to minimize the Pitch angle.
Figure 2.31 - Pitch angle
The Skew angle is represented by the value S in Figure 2.32. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS6100.
S
Figure 2.32 - Skew angle T
The Tilt angle is represented by the value T in Figure 2.33. For advanced code reconstruction, see par. 3.1.1.
Figure 2.33 - Tilt angle
2.28 - Installation
Page 44
DATALOGIC
!
DS6100
2.7 FOCUS ADJUSTMENT
Before installing the DS6100, the operator should select a specific reading area by means of the optical system for manual adjustment of the focal length. The focus adjustment is obtained by rotating a regulation screw which moves the internal lenses and therefore causes the laser beam focusing position to change. Seven marks, numbered from 0 to 6, are printed on the regulation screw to indicate the different positions of the internal optics. The diagram in par. 3.3 shows the reading performance that can be obtained from DS6100 scanners when operating with different focus positions and barcode label densities. Even though the screw is marked with seven positions, the focus adjustment is continuous and not by step; this allows an optimum adjustment around the selected position.
WARNING The scanner must be disconnected from the power supply during this operation to avoid hazardous visible laser light.
Refer to the following instructions when adjusting the focus: 1) Unscrew the focus regulation cover (Figure A,
3
) near the laser output window for access to the focus adjustment screw. 2) Carefully turn the screw counterclockwise until the number 0 is aligned with the notch as shown in the following figure. 3) Now turn the focus adjustment screw clockwise to reach the desired position (refer to the reading diagrams in par. 3.3).
Installation - 2.29
Page 45
DS6100
DATALOGIC
NOTE The focus adjustment screw is positioned by default at the value 2.
Figure 2.34 - Focus regulation
2.8 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout.
These layouts also require the correct setup of the software configuration parameters. See the WinHost Help On Line.
2.8.1 Standard (Point-to-Point) Using a point-to-point layout, the data is transmitted on the Auxiliary interface as well as on the Main interface. The Main interface can be selected for RS232, RS485 full-duplex or if INT-26 is installed, 20 mA C.L. communications. RS485 half-duplex communications cannot be used on either interface in this layout. Programming in Host Mode can be accomplished through the Main interface or Auxiliary interface. Terminal
2
DS6100 1 Host 3 1
Main serial interface
2
Auxiliary serial interface
3
Presence sensor (for On-Line mode)
Figure 2.35 - Point-to-Point layout
2.30 - Installation
Page 46
DATALOGIC
DS6100
When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
2.8.2 Pass Through Pass Through mode allows two or more devices to be connected to a single external serial interface. The DS6100 transmits the messages received by its auxiliary interface (RS232 only) onto its main interface. In this configuration a series of scanners can be connected together using RS232 on the main interface and all messages 1 Main serial interface will be passed through this Host 2 Auxiliary serial interface chain to the host. The 3 Presence sensor (for On-Line mode) reading phase of each Hand-Held reader 1 scanner is independent from the others in a Pass 2 Through chain. 1 Applications can be implemented to connect a device such as a hand-held reader to the Auxiliary port for manual code reading capability.
DS6100
3
DS6100
3
Figure 2.36 - Pass through layout
2.8.3 RS485 Master/Slave The RS485 Master/Slave connection is used to collect data from several scanners to build either an omni-directional or multi-sided reading system; there can be one Master and up to 8 Slaves connected together. The Master and Slave scanners are connected together using RS485 halfduplex on the auxiliary serial interface. The Master scanner is also connected to either a Host or a Multiplexer on the main serial interface. The possible main interface type selections are RS232
Installation - 2.31
Page 47
DS6100
DATALOGIC or RS485 full-duplex for Host connections or RS485 half-duplex for Multiplexer connections. For the Slave scanners the Multidrop Address Selection can be made using the DIP switch. The addresses must be consecutive and different from zero for hardware configuration, or be selected in software, (in this case the DIP switch address must be zero for each Slave). See "Multidrop Address Selection" in par. 2.2.1.
NOTE The main serial port of the Slave scanners can be used for configuration. The termination resistors of the RS485 bus must not be installed.
Single P.S. The P.S. signal is unique to the system; there is a single reading phase and a single message from the Master scanner to the Host. The On-Line operating mode is used for this layout.
DS6100 Slave
1
MULTIPLEXER MX4000 RS485 half-duplex
2 DS6100 Slave
RS232 RS485 full-duplex
3
DS6100 Master
1 Main serial interface 2 Auxiliary serial interface: RS485 HD 3 Presence sensor Figure 2.37 - Master-slave Single P.S. layout
2.32 - Installation
HOST PC or PLC
Page 48
DATALOGIC
DS6100
Multi P.S. In this layout, each DS6100 has its own P.S. and therefore multiple reading phases. The master sends the individual messages collected from the multidrop line as well as its own to the Host or Multiplexer. The On-Line or Automatic operating modes are used for this layout. MULTIPLEXER MX4000
2
DS6100 Master
2
DS6100 Slave
RS485 half-duplex
1 HOST PC or PLC
3
3
RS232 RS485 full-duplex
1 Main serial interface 2 Auxiliary serial interface: RS485 HD 3 Presence sensor (for On-Line mode) Figure 2.38 - Multi P.S. layout connections
2.8.4 Multiplexer Each scanner is connected to a multiplexer (MX4000 for example) with the RS485 half-duplex mode on either the main or the auxiliary interface. The other interface is not used. 31
1
0
MX4000
Host
P.S.
P.S.
P.S.
Figure 2.39 - Multiplexer layout
Installation - 2.33
Page 49
DS6100
DATALOGIC
2.8.5 MUX24HS Each scanner is connected to MUX24HS with the RS485 half-duplex mode on the auxiliary serial interface. The main interface is not used. The GOOD READ output signal of each scanner is wired to a separate input line of the MUX24HS, while the Presence Sensor signal is common to all the scanners and to the P.S. input line of the MUX24HS. MUX24HS up to 23 inputs from scanners (good read)
1
2
3
4 multidrop line RS485
5 reading attempted by up to 23 scanners console (COM1)
PS to all the scanners host (AUX1) 23
7
6
Figure 2.40 - MUX24HS layout
2.8.6 PackTrack Omnidirectional Reading Two or more DS6100 junction box model scanners are correctly positioned in a Master/Slave Single P.S. type layout using the XBOX-05 connection box to compose an omni-directional reading station. This is the indicated layout for PackTrack operating mode. reading area
XMF-05 HOST
XBOX-05 code motion
System Power Supply
ENCODER
DS6100
P.S. PHOTOCELL
Figure 2.41 - Omnidirectional reading
2.34 - Installation
Page 50
DATALOGIC
DS6100
3 READING FEATURES 3.1 ADVANCED CODE RECONSTRUCTION The traditional way of barcode reading could be called "Linear Reading". In this case, the laser beam crosses the barcode symbol from its beginning to its end as shown in Figure 3.1.
Laser Beam
Figure 3.1 - Linear reading
In Advanced Code Reconstruction mode it is no longer necessary for the laser beam to cross the label from the start to the end. With just a set of partial scans on the label (obtained using the motion of the label itself), the DS6100 is able to "reconstruct" the barcode. A typical set of partial scans is shown in Figure 3.2.
Code Direction Figure 3.2 - Partial scans
None of the partial scans contains the whole label. The decoder aligns each partial scan correctly and combines them in order to obtain the entire code. The alignment is performed by calculating the time difference from one partial scan to another using a reference code element.
3.1.1 Tilt Angle for Advanced Code Reconstruction The most important parameter in Advanced Code Reconstruction is the value of the maximum tilt angle (α maximum) under which the code reconstruction process is still possible. 0° to α max Laser Beam We define the Tilt angle as the angle (α) α = tilt angle between the laser beam and a line parallel to the barcode label, as shown in Figure 3.3. α
Figure 3.3 - Tilt angle
Reading Features - 3.1