Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 6

DS6100 Installation Manual, pages 51 to 59

Pages 51 to 59 of 59

The original document is the PDF (785 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-6100

Page 51

DS6100

DATALOGIC

The formulas to calculate α maximum depend on various parameters such as: label height, number of scans per second, code motion speed, etc. To obtain α maximum for your application, please contact your Datalogic representative. You must remember that the decoder will be able to read the label with a tilt angle between + α max and - α max as shown in Figure 3.4 (the shaded zones are the NO READ zones).

0°

−α +α

Laser Beam

Figure 3.4 - Reading zones with α max

3.2 PERFORMANCE It is possible to change the focus of the DS6100 in order to reach the reading distance expected. The scan rate is 800 scans / sec. Refer to the diagrams in par. 3.3 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25 °C ambient temperature depending on the conditions listed in Figure 3.5. If standard models do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities.

3.3 READING DIAGRAMS The diagrams on the following pages show the reading distance for barcodes with different densities and refer to two laser beam apertures. The following table illustrates the convention used for reading diagrams and the operating conditions of the scanners that refer to these measures:

3.2 - Reading Features

Page 52

DATALOGIC

DS6100

CONDITIONS Code = PCS = "Pitch" angle = "Skew" angle = "Tilt" angle = Operating mode =

Interleaved 2/5 and Code 39 according to Datalogic Barcode Test Chart 0.90 0° 10° 0° linear

C B A

D

30° 50°

50° 30° A B C D

= = = = minimum reading distance maximum reading distance at 50° aperture maximum reading distance at 30° aperture laser beam aperture

Figure 3.5 - Reading diagram conventions and operating conditions

30° aperture angle 50° aperture angle

0.30 mm

0.50 mm

1.00 mm

Figure 3.6 - Reading distances for DS6100

Reading Features - 3.3

Page 53

DS6100

DATALOGIC

Example: The following figure shows the reading diagram obtained for the DS6100 operating with focus screw set at position 6 and barcode density of 0.50 mm. From figure 3.5 you will get the following reading distances: Minimum = 450 mm Maximum at 50° of laser beam aperture = 1050 mm Maximum at 30° of laser beam aperture = 1250 mm Note: (0,0) is the center of the laser beam output window 0

200

400

1000

600

800

1000 1200 1400 1600 1800 2000 [mm] 1000

800

800

600

600

400

400

200

200

0

0

200

200

400

400

600

600

800

800

1000

1000 Figure 3.7 - Example of reading diagram for DS6100

3.4 - Reading Features

Page 54

DATALOGIC

0

DS6100

500

100

200

300

400

500

600

700

800

900

1000[mm] 500

400

400

300

300

200

200

100

100

0

0

100

100

200

200

300

300

400

400

500

500 Figure 3.8 - Empty grid for DS6100: reading distance from 0 to 1000 mm

Reading Features - 3.5

Page 55

DS6100

DATALOGIC

0

200

400

1000

600

800

1000 1200 1400 1600 1800 2000 [mm] 1000

800

800

600

600

400

400

200

200

0

0

200

200

400

400

600

600

800

800

1000

1000 Figure 3.9 - Empty grid for DS6100 reading distance from 0 to 2000 mm

3.6 - Reading Features

Page 56

DATALOGIC

DS6100

4 MAINTENANCE 4.1 CLEANING Clean the laser beam output window (Figure A,

1

) periodically for correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.

WARNING Clean the window of the DS6100 when the scanner is turned off or at least when the laser beam is not active.

Maintenance - 4.1

Page 57

DS6100

DATALOGIC

This page is intentionally left blank.

4.2 - Maintenance

Page 58

DATALOGIC

DS6100

5 TECHNICAL FEATURES ELECTRICAL FEATURES (see note 1) Supply voltage Power consumption

10 to 30 V 10 W max.

INPUTS/OUTPUTS Serial interfaces Main

Auxiliary Baud Rates Command inputs (NPN or PNP)

Outputs (open emitter or collector)

RS232 RS485 full-duplex, RS485 half-duplex 20 mA C.L. (only with INT-26 accessory) RS232, RS485 half-duplex 1200 to 57600 Presence sensor 1 (optocoupled) Presence sensor 2 (optocoupled) Encoder input (optocoupled) NO READ (optocoupled) RIGHT CODE (optocoupled)

OPTICAL FEATURES (see note 1) Light source Wave length Safety class Light receiver semiconductor laser diode 650 to 680 nm Class 2 - IEC 825-1; Class II - CDRH Avalanche photodiode

READING FEATURES Scan rate Maximum resolution Max. reading distance Max. reading width Max. depth of field Aperture angle

800 scans/s (see reading diagrams)

USER INTERFACE LCD Display 4 key keypad Beeper LED indicators

2 lines, 16 characters laser beam active reading phase active barcode label presence data transmit

Technical Features - 5.1

Page 59

DS6100

DATALOGIC

SOFTWARE FEATURES Readable code families

Code selection Decoding safety Headers and Terminators Operating modes

Configuration modes WinHost utility program KEYBOARD MODE HOST MODE Parameter storage

Interleaved 2/5 EAN/UPC Code 39 Codabar Code 128 Code 93 EAN128 Up to 5 codes during one reading phase Several good reads of the same code can be enabled separately for each code Transmitted messages can be personalized using up to 4 headers and 4 terminators ON LINE SERIAL ON LINE AUTOMATIC TEST PACK TRACK™ using the built-in keypad receiving commands from the serial port Non-volatile internal EEPROM

ENVIRONMENTAL FEATURES Operating temperature (see note 2) Storage temperature Humidity Vibration resistance

Shock resistance

Protection class

0 to 40 °C -20 to 70 °C 90% non condensing IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30 G; 11 ms; 3 shocks on each axis IP-65

PHYSICAL FEATURES Mechanical dimensions Weight

100 x 180 x 72 mm 1,250 gr.

Note 1:

The features given are typical at 25 °C ambient temperature (if not otherwise indicated).

Note 2:

If the reader is used in high temperature environments (over 35 °C), use of the Beam Shutter is advised (for details refer to the information in the Winhost Help On Line provided on diskette).

5.2 - Technical Features