Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 6

DS6100 Installation Manual, pages 31 to 40

Pages 31 to 40 of 59

The original document is the PDF (785 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-6100

Page 31

DS6100

DATALOGIC

2.5.1 Power Supply The supply voltage for correct operation of the scanner must be between 10 and 30 VDC. The max. power consumption is 10 W. The power block (optional), supplies the power necessary for the DS6100 and allows mains power to be used. A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from the power on of the scanner.

2.5.2 Main Serial Interface The main serial interface is compatible with the following electrical standards: RS232 RS485 full-duplex RS485 half-duplex 20 mA current loop The 20 mA Current Loop interface is available if the optional INT-26 accessory is installed. This accessory interface replaces the RS232/RS485 selections.

The main serial interface type and its relative parameters (baud rate, data bits, etc.) are selected via software either using the WinHost utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the WinHost Help On Line. Details regarding the connections and use of the main interface selection are given in the next paragraphs.

2.16 - Installation

Page 32

DATALOGIC

DS6100

RS232 Interface The main serial interface is used in this case for point-to-point connections; it handles communication with the Host computer and allows both transmission of code data and configuring the scanner. The following pins of the 19-pin connector are used for RS232 interface connection: Pin R T P S N

Name TX232 RX232 RTS232 CTS232 SGND

Function transmit data receive data request to send clear to send signal ground

The RTS and CTS signals control data transmission and synchronize the connected devices. If the RTS/CTS hardware protocol is enabled, the DS6100 activates the RTS output to indicate a message can be transmitted. The receiving unit must activate the CTS input to enable the transmission. RTS232 SGND

TX232

CTS232

RX232

DS6100

USER INTERFACE T

RX232

R

TX232

P

RTS232

S

CTS232

N

SGND

TXD RXD

SGND

Figure 2.16 - RS232 connections

Installation - 2.17

Page 33

DS6100

DATALOGIC

RS485 Full-Duplex Interface The RS485 full-duplex interface is used for non-polled communication protocols in point-to-point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The following pins of the 19-pin connector are used for RS232 interface connection: Pin R P T S V

Name TX485+ TX485RX485+ RX485GNDRS485 TX485+

Function RS485 transmit data + RS485 transmit data RS485 receive data + RS485 receive data RS485 ground reference TX485-

GNDRS485

RX485-

RX485+

DS6100

USER INTERFACE R

TX485+

P

TX485-

T

RX485+

S

RX485-

V

GNDRS485

RX485

TX485

GND

Figure 2.17 - RS485 full-duplex interface connections

2.18 - Installation

Page 34

DATALOGIC

DS6100

RS485 Half-Duplex Interface The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be used for Multidrop connections in a master-slave layout or with a Datalogic Multiplexer, (see par. 2.8.3, 2.8.4 and 2.8.5). Device connection to the Multidrop line can be controlled externally through the RS485CNTR line. For example, it may be necessary to disconnect a scanner from the line if the device is damaged or the line is overloaded. To do this, apply a voltage from 12 to 30 Vdc to the RS485CNTR signal using GND as a reference. The following pins of the 19-pin connector are used for RS232 interface connection: Pin R P V U

Name RTX485+ RTX485GNDRS485 RS485CNTR

Function RS485 transmit/receive data + RS485 transmit/receive data RS485 ground reference multidrop device disconnect

RTX485-

RS485CNTR

RTX485+

GNDRS485

DS6100

Vext 12 to 30 Vdc

B

USER INTERFACE

VS

V GNDRS485

1

R

RTX485+

7

P

RTX485-

6

U

RS485CNTR

A

GND

RS485GND RXTX+ RXTX-

GND

Figure 2.18 - RS485 half-duplex interface connections

Installation - 2.19

Page 35

DS6100

DATALOGIC

The figure below shows a multidrop configuration with DS6100 scanners connected to a Multiplexer. max. 2 m.

120 Ohm

R

DS6100 #x (up to 31)

P V

R

DS6100 #1

P V

R

DS6100 #0

P V max. 1200 m.

RTX485+ RTX485GNDRS485

RTX485+ RTX485-

MULTIPLEXER RS485REF

120 Ohm

Figure 2.19 - DS6100 Multidrop connection to a Multiplexer

2.20 - Installation

Page 36

DATALOGIC

DS6100

20 mA Current Loop (INT-26 Accessory Only) When the INT-26 accessory board is installed, the DS6100 is equipped with a 20 mA current loop interface. The INT-26 board supports both active and passive type connections. The following pins of the 19-pin output connector are used for the connections: Pin U V N R P T S

Name DRVIN DRVOUT CLGND CLOUT+ CLOUTCLIN+ CLIN-

Function input current generator output current generator generator reference current Loop output + current Loop output current Loop input + current Loop input -

CLOUTCLGND CLOUT+ DRVIN CLINDRVOUT CLIN+

DS6100

USER INTERFACE

I = 20 mA V

DRVOUT

R C.L. OUT+ P

C.L. OUT-

N

CLGND

U

DRVIN

SGND

I = 20 mA T C.L. IN+ S

C.L. IN-

GND MAX. 300 METERS

Figure 2.20 - 20 mA C.L. active connections

Installation - 2.21

Page 37

DS6100

DATALOGIC

DS6100

USER INTERFACE + T

C.L. IN+

S

C.L. IN-

R

C.L. OUT+

P

C.L. OUT-

+

MAX. 300 METERS

Figure 2.21 - 20 mA C.L. passive connections

2.5.3 Auxiliary Interface The auxiliary serial interface is equipped with both RS232 and RS485 halfduplex interface connections. The interface type is exclusive and is selectable through the WinHost configuration program. The following pins of the 19-pin connector are used: Pin J L N K M V

Name RXA TXA SGND AUX485 + AUX485 GNDRS485

Function RS232 receive data RS232 transmit data signal ground RS485 receive/transmit data + RS485 receive/transmit data RS485 ground reference

AUX485SGND TXA AUX485+ RXA GNDRS485

2.22 - Installation

Page 38

DATALOGIC

DS6100

DS6100

USER INTERFACE J

RXA

L

TXA

N

SGND

TXD RXD GND

Figure 2.22 - RS232 Auxiliary interface connections

DS6100

USER INTERFACE K

AUX485+

M

AUX485-

V

GNDRS485

RTX+ RTXGND

Figure 2.23 - RS485 Auxiliary interface connections

NOTE The auxiliary RS485 half-duplex interface cannot be selected if the main interface is 20 mA C.L.

2.5.4 Inputs The inputs of the scanner are on the 6-pin circular connector (Figure B, 14 ) on the body of the DS6100. These inputs are called ENC, PS1 and PS2. ENC is the Encoder input. In PackTrack™ mode, it detects the conveyor speed. PS1 is the main presence sensor. When active, this input tells the scanner to scan for a code and that decoding can take place. The yellow LED (Figure A, 9 ) indicates the PS1 is active.

Installation - 2.23

Page 39

DS6100

DATALOGIC

PS2 can be used as the stop signal for the reading phase. All inputs are optocoupled and driven by a constant current generator; the command signal is filtered through an anti-disturbance circuit which generates a delay of about 5 ms for PS1 and PS2 and 500 µs for ENC. For PS1 and PS2, the NPN or PNP connection must be made by setting the jumper as shown in par. 2.2.2. Vext

DS6100

+ 5V

A

VS

D/C

PS1+/PS2+

B

GND

PRESENCE SENSOR V

PSIN

Figure 2.24 - Presence sensor input PNP command

Vext

DS6100 + 5V

A

VS

D/C

PS1-/PS2-

B

GND

PRESENCE SENSOR V

PSIN

Figure 2.25 - Presence sensor input NPN command

ENCODER

DS6100 A

VS

E

ENC+

F

ENC-

B

GND

+ 5V

V

Ground

Signal

Figure 2.26 - Encoder NPN input command using DS6100 power

2.24 - Installation

Page 40

DATALOGIC

DS6100

Vext

DS6100

ENCODER

+ 5V E

ENC+

F

ENC-

V

Signal

Figure 2.27 - Encoder NPN input command using external power

ENCODER

DS6100 A

VS

E

ENC+

F

ENC-

B

GND

+ 5V

Figure 2.28 - Encoder PNP input command using DS6100 power

Vext

DS6100

ENCODER V

+ 5V E

ENC+

F

ENC-

Signal

Figure 2.29 - Encoder PNP input command using external power

Isolation between the command logic and the scanner is maintained by powering the inputs with a different supply voltage (Vext) from that supplied on the 6-pin connector (VS). The driving logic of the input signals may be powered, for convenience, with the voltage supply between pins A (VS) and B (GND) of the connector. In this case, however, the device is no longer electrically isolated.

Installation - 2.25