The text of a manual · part 3 of 6
DS6100 Installation Manual, pages 21 to 30
Pages 21 to 30 of 59
The original document is the PDF (785 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-6100
Page 21
DS6100
!
DATALOGIC
2.2.2 Input Selection
Two presence sensor inputs are provided (PS1 and PS2). They can be selected as both positive inputs (PNP) or as both negative inputs (NPN). To select the Input type proceed as follows: 1. Open the panel as described in par. 2.2. 2. Position the jumpers as desired, referring to Figure 2.4.
Connector Panel
Junction Box Cable Panel
NPN
NPN PNP
Figure 2.4 – Input selection for DS6100
2.6 - Installation
PNP
Page 22
DATALOGIC
DS6100
2.3 MECHANICAL INSTALLATION DS6100 can be installed to operate in any position. There are 16 screw holes (M5 X 8) on the sides of the scanner for mounting. The diagrams below give all the information required for installation; refer to par. 2.6 for correct positioning of the scanner with respect to the code passage zone.
mm in
Figure 2.5 - DS6100 overall dimensions - connector model
Installation - 2.7
Page 23
DS6100 DATALOGIC
30 18 © q ©o =, - = 72 8 g-§3 ~ 3.33 = 85 = 50.5 < 100 A] 6 20, P 3.35 1.99 o|N 3.94 0.24}|/0.79 FF] OTD Teh © a EH | ol shal F ! | | eH |I7 o = | A |} ome Ald ae | ! 1 oO sl _ IDSE100 ot 38 {|_| [| ey || LEAL BI? | | ~ |, te ese no it I]! : c - 14 0.36 XXX) cS a LEE WV TT M5 _N°16 = 645 _ 3.33 om OO ofc] E mm in
GLANDS PG7 N°6
Figure 2.6 - DS6100 overall dimensions - junction box model.
2.8 - Installation
Page 24
DATALOGIC
DS6100
2.4 JUNCTION BOX INSTALLATION The junction box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to other standard connectors provided. Figure 2.7 shows the basic layout of a scanner using the junction box. For junction box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the Junction Box junction box. The system cables pass through 6 glands in the side of Scanner cable DS6100 the junction box and the individual wires connect to spring clamp System cables terminal blocks inside which provide access to all scanner signals. Figure 2.7 - Scanner using junction box
Refer to Figure 2.6 for the overall dimensions of the junction box.
2.4.1 Junction Box Mounting The junction box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel. 2) Align the junction box and insert the two self-threading screws with their washers and screw them into the panel until tight (see Figure 2.8). Figure 2.8 - Junction box mounting
Installation - 2.9
Page 25
DS6100
DATALOGIC
2.4.2 Junction Box Electrical Connections The connection and wiring procedure for the junction box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: • Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm. • Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 2.9). • Insert the wire into the clamp and release the lever. The wire will now be held in the spring clamp.
Figure 2.9 - System cable connections to the junction box
The wiring used can be solid or stranded but must meet the following specifications: Positions 1-4: 24 - 16 AWG 0,2 - 1,5 mm2 Positions 5-39: 26 - 20 AWG 0,14 - 0,5 mm2
2.10 - Installation
Page 26
DATALOGIC
DS6100
The junction box pinouts are indicated in the following table: 18
J1
39
1
5
17
Figure 2.10 - Junction box connector and pinout
Pin
Name
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
VS GND VS GND CHASSIS VS VS ENC+ ENCGND GND VS VS PS1+/PS2+/GND GND NOREAD+ NOREADRIGHT+
Pin
RS232
24,29 25,30 26,31 27 28 32 33
TX232 RTS232
SGND RX232 CTS232
J. BOX Pinout for DS6100 Pin Name 21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39
RS485 full-duplex TX485+ TX485GNDRS485
RX485+ RX485-
RIGHTSPS+ SPS-
Main interface signals see table below
SGND TXA AUX485+ SGND RXA AUX485-
RS485 half-duplex RTX485+ RTX485GNDRS485 RS485CNTR
20 mA C.L. (INT-26 Only) CL OUT+ CL OUTDRVOUT DRVIN CLGND CL IN+ CL IN-
* The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (i.e. Multiplexer using the RS485 half-duplex interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.
Installation - 2.11
Page 27
DS6100
DATALOGIC
4) After wiring the junction box and while the scanner is unplugged from the power, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 2.11.
Rubber seal
J1
Scanner cable
Figure 2.11 - Scanner cable connections to the junction box
5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing.
The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the junction box, simply reverse the procedure in step 4.
2.12 - Installation
Page 28
DATALOGIC
DS6100
2.5 ELECTRICAL CONNECTIONS FOR CONNECTOR MODELS DS6100 is available with two different electrical connection systems: DS6100 junction box version It is equipped with a cable that connects the junction box which houses spring clamp terminal blocks for the connections to the power supply and the input/output signals (refer to par. 2.4). DS6100 connector version It is equipped with 4 connectors for the following signals: • Power supply
(male, 3 pins)
• Presence sensors
(female, 6 pins) (Figure B, 14 )
(Figure B, 13 )
• Output/Serial interfaces (female, 19 pins) (Figure B, 12 ) • Oscillating mirror
(female, 2 pins) (Figure B, 15 )
Power supply connector
GND TO DS6100 CHASSIS
VS (10 to 30 VDC)
Figure 2.12 - Power supply connector
Power supply pinout Pin A B C
Name GND VS CHASSIS
Function Supply voltage Supply voltage + Chassis Ground
Installation - 2.13
Page 29
DS6100
DATALOGIC
Input connector VS
GND ENC-
ENC+
PS2+/-
PS1+/Figure 2.13 - Input connector
Pin A B C D E F
Input pinout Function Power for external devices + Power for external devices Presence sensor 2 Presence sensor 1 Encoder (Positive pin) Encoder (Negative pin)
Name VS GND PS2+/PS1+/ENC+ ENC-
Oscillating mirror connector
1 2
VS1
GND
Figure 2.14 - Oscillating mirror connector
Pin 1 2
Name VS1 GND
Oscillating mirror pinout Function Supply voltage (output) + Supply voltage (output) -
This output passes the operating power supply voltage from the scanner to the oscillating mirror. It is physically the same as the input power supplied to the DS6100.
2.14 - Installation
Page 30
DATALOGIC
DS6100
Output/Serial interface connector (A) GND (B) VS
(N) SGND
(M) AUX485(L) TXA (K) AUX485+ (J) RXA
(C) NO READ(D) NO READ+ (E) RIGHT-
(H) SPS+
(F) RIGHT+
(G) SPS-
(P) (R) (S) (T) (U)(V) P1 P2 P3 P4 P5 P6
Figure 2.15 - Output/Serial interface connector
Pin
Name
A B C D E F G H J K L M
GND VS NO READNO READ+ RIGHTRIGHT+ SPSSPS+ RXA AUX485+ TXA AUX485-
Output/Serial interface pinout Function supply voltage supply voltage + no read output no read output right code output right code output slave presence sensor slave presence sensor Auxiliary serial interface (see par. 2.6.3)
RS232 N P R S T U V
Main serial interface (see par. 2.6.2)
SGND RTS232 TX232 CTS232 RX232
RS485 full-duplex
RS485 half-duplex
TX485TX485+ RX485RX485+
RTX485RTX485+
GNDRS485
RS485CNTR GNDRS485
20 mA C.L. (INT-26 Only) CLGND CL OUTCL OUT+ CL INCL IN+ DRVIN DRVOUT
Installation - 2.15