2.2.2 Input Selection

Two presence sensor inputs are provided (PS1 and PS2). They can be selected as both positive inputs (PNP) or as both negative inputs (NPN). To select the Input type proceed as follows: 1. Open the panel as described in par. 2.2. 2. Position the jumpers as desired, referring to Figure 2.4.

Connector Panel

Junction Box Cable Panel

NPN

NPN PNP

Figure 2.4 – Input selection for DS6100

2.6 - Installation

PNP

Page 22

DATALOGIC

DS6100

2.3 MECHANICAL INSTALLATION DS6100 can be installed to operate in any position. There are 16 screw holes (M5 X 8) on the sides of the scanner for mounting. The diagrams below give all the information required for installation; refer to par. 2.6 for correct positioning of the scanner with respect to the code passage zone.

mm in

Figure 2.5 - DS6100 overall dimensions - connector model

Installation - 2.7

Page 23 read from a scan by OCR; it may hold reading errors

DS6100 DATALOGIC

30 18 © q ©o =, - = 72 8 g-§3 ~ 3.33 = 85 = 50.5 < 100 A] 6 20, P 3.35 1.99 o|N 3.94 0.24}|/0.79 FF] OTD Teh © a EH | ol shal F ! | | eH |I7 o = | A |} ome Ald ae | ! 1 oO sl _ IDSE100 ot 38 {|_| [| ey || LEAL BI? | | ~ |, te ese no it I]! : c - 14 0.36 XXX) cS a LEE WV TT M5 _N°16 = 645 _ 3.33 om OO ofc] E mm in

GLANDS PG7 N°6

Figure 2.6 - DS6100 overall dimensions - junction box model.

2.8 - Installation

Page 24

DATALOGIC

DS6100

2.4 JUNCTION BOX INSTALLATION The junction box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to other standard connectors provided. Figure 2.7 shows the basic layout of a scanner using the junction box. For junction box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the Junction Box junction box. The system cables pass through 6 glands in the side of Scanner cable DS6100 the junction box and the individual wires connect to spring clamp System cables terminal blocks inside which provide access to all scanner signals. Figure 2.7 - Scanner using junction box

Refer to Figure 2.6 for the overall dimensions of the junction box.

2.4.1 Junction Box Mounting The junction box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel. 2) Align the junction box and insert the two self-threading screws with their washers and screw them into the panel until tight (see Figure 2.8). Figure 2.8 - Junction box mounting

Installation - 2.9

Page 25

DS6100

DATALOGIC

2.4.2 Junction Box Electrical Connections The connection and wiring procedure for the junction box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: • Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm. • Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 2.9). • Insert the wire into the clamp and release the lever. The wire will now be held in the spring clamp.

Figure 2.9 - System cable connections to the junction box

The wiring used can be solid or stranded but must meet the following specifications: Positions 1-4: 24 - 16 AWG 0,2 - 1,5 mm2 Positions 5-39: 26 - 20 AWG 0,14 - 0,5 mm2

2.10 - Installation

Page 26

DATALOGIC

DS6100

The junction box pinouts are indicated in the following table: 18

J1

39

1

5

17

Figure 2.10 - Junction box connector and pinout

Pin

Name

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20

VS GND VS GND CHASSIS VS VS ENC+ ENCGND GND VS VS PS1+/PS2+/GND GND NOREAD+ NOREADRIGHT+

Pin

RS232

24,29 25,30 26,31 27 28 32 33

TX232 RTS232

SGND RX232 CTS232

J. BOX Pinout for DS6100 Pin Name 21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39

RS485 full-duplex TX485+ TX485GNDRS485

RX485+ RX485-

RIGHTSPS+ SPS-

Main interface signals see table below

SGND TXA AUX485+ SGND RXA AUX485-

RS485 half-duplex RTX485+ RTX485GNDRS485 RS485CNTR

20 mA C.L. (INT-26 Only) CL OUT+ CL OUTDRVOUT DRVIN CLGND CL IN+ CL IN-

* The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (i.e. Multiplexer using the RS485 half-duplex interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.

Installation - 2.11

Page 27

DS6100

DATALOGIC

4) After wiring the junction box and while the scanner is unplugged from the power, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 2.11.

Rubber seal

J1

Scanner cable

Figure 2.11 - Scanner cable connections to the junction box

5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing.

The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the junction box, simply reverse the procedure in step 4.

2.12 - Installation

Page 28

DATALOGIC

DS6100

2.5 ELECTRICAL CONNECTIONS FOR CONNECTOR MODELS DS6100 is available with two different electrical connection systems: DS6100 junction box version It is equipped with a cable that connects the junction box which houses spring clamp terminal blocks for the connections to the power supply and the input/output signals (refer to par. 2.4). DS6100 connector version It is equipped with 4 connectors for the following signals: • Power supply

(male, 3 pins)

• Presence sensors

(female, 6 pins) (Figure B, 14 )

(Figure B, 13 )

• Output/Serial interfaces (female, 19 pins) (Figure B, 12 ) • Oscillating mirror

(female, 2 pins) (Figure B, 15 )

Power supply connector

GND TO DS6100 CHASSIS

VS (10 to 30 VDC)

Figure 2.12 - Power supply connector

Power supply pinout Pin A B C

Name GND VS CHASSIS

Function Supply voltage Supply voltage + Chassis Ground

Installation - 2.13

Page 29

DS6100

DATALOGIC

Input connector VS

GND ENC-

ENC+

PS2+/-

PS1+/Figure 2.13 - Input connector

Pin A B C D E F

Input pinout Function Power for external devices + Power for external devices Presence sensor 2 Presence sensor 1 Encoder (Positive pin) Encoder (Negative pin)

Name VS GND PS2+/PS1+/ENC+ ENC-

Oscillating mirror connector

1 2

VS1

GND

Figure 2.14 - Oscillating mirror connector

Pin 1 2

Name VS1 GND

Oscillating mirror pinout Function Supply voltage (output) + Supply voltage (output) -

This output passes the operating power supply voltage from the scanner to the oscillating mirror. It is physically the same as the input power supplied to the DS6100.

2.14 - Installation

Page 30

DATALOGIC

DS6100

Output/Serial interface connector (A) GND (B) VS

(N) SGND

(M) AUX485(L) TXA (K) AUX485+ (J) RXA

(C) NO READ(D) NO READ+ (E) RIGHT-

(H) SPS+

(F) RIGHT+

(G) SPS-

(P) (R) (S) (T) (U)(V) P1 P2 P3 P4 P5 P6

Figure 2.15 - Output/Serial interface connector

Pin

Name

A B C D E F G H J K L M

GND VS NO READNO READ+ RIGHTRIGHT+ SPSSPS+ RXA AUX485+ TXA AUX485-

Output/Serial interface pinout Function supply voltage supply voltage + no read output no read output right code output right code output slave presence sensor slave presence sensor Auxiliary serial interface (see par. 2.6.3)

RS232 N P R S T U V

Main serial interface (see par. 2.6.2)

SGND RTS232 TX232 CTS232 RX232

RS485 full-duplex

RS485 half-duplex

TX485TX485+ RX485RX485+

RTX485RTX485+

GNDRS485

RS485CNTR GNDRS485

20 mA C.L. (INT-26 Only) CLGND CL OUTCL OUT+ CL INCL IN+ DRVIN DRVOUT